SECTION 6: SERVICE
Review the troubleshooting and procedures in this section to fix or adjust your machine if a problem devel- ops. If you need replacement parts or you are unsure of your repair skills, then feel free to call our Technical Support at (570)
Troubleshooting
Motor and Electrical
Symptom | Possible Cause | Possible Solution | ||
Reduced performance with new filters. | 1. | Paint | 1. | Check exhaust fan blades and |
|
| or exhaust duct. |
| exhaust duct and, if needed, clean |
|
|
|
| with |
|
|
|
|
|
Motor producing unusual noise or | 1. | Motor mounting hardware loose or | 1. | Tighten motor mounting hardware. |
vibrations. |
| fan loose. |
| Tighten fan. |
|
|
|
|
|
Spray Booth Operations
Symptom | Possible Cause | Possible Solution | ||
Too little airflow in booth. | 1. | The filter is dirty. | 1. | Change the filters. |
| 2. | Obstructions exist in front of the | 2. | Remove obstructions. |
|
| filters. | 3. | Change filters to meet correct |
| 3. | Filters do not meet design |
| specifications. |
|
| specifications. | 4. | Clean fan. |
| 4. Fan is dirty. | 5. | Make sure all filters are installed and | |
| 5. | Filters not installed correctly. |
| properly seated. |
|
|
|
|
|
Too much airflow in booth. | 1. | Filters are not correctly seated. | 1. | Make sure all filters are installed and |
|
|
|
| properly seated. |
|
|
|
|
|
The filter indicator does not work | 1. | Fluid level is low. | 1. | Check fluid level and add fluid as |
properly. |
|
|
| needed. |
| 2. | Obstructions exist in hoses. | 2. | Remove obstructions from hoses. |
| 3. | Air filter indicator is not level. | 3. | Loosen manometer mounting |
|
|
|
| hardware, level using sight glass, |
|
|
|
| and tighten mounting hardware. |
|
|
|
|
|
Model G0533 (Mfg. Since 3/11) |