Grizzly G0533 owner manual Machine Data Sheet

Page 5

Data Sheet

MACHINE DATA

SHEET

Customer Service #: (570) 546-9663 · To Order Call: (800) 523-4777 · Fax #: (800) 438-5901

MODEL G0533 3 HP DRY SPRAY BOOTH

Product Dimensions:

 

Weight

607 lbs.

Width (side-to-side) x Depth (front-to-back) x Height

63 x 52 x 100 in.

Footprint (Length x Width)

51 x 24 in.

Shipping Dimensions:

 

Type

Cardboard/Wood Runne

Content

Machine

Weight

754 lbs

Length x Width x Height

52 x 27 x 77 in.

Electrical:

 

Power Requirement

230V, Single-Phase, 60 Hz

Full-Load Current Rating

15A

Minimum Circuit Size

20A

Switch

Magnetic

Switch Voltage

220V

Cord Length

4 ft.

Plug Included

No

Recommended Plug/Outlet Type

Hardwire

Motors:

 

Main

 

Type

Explosion Proof

Horsepower

3 HP

Voltage

230V

Phase

Single

Amps

15A

Speed

1725 RPM

Cycle

60 Hz

Number of Speeds

1

Power Transfer

Direct Drive

Bearings

Special Explosion Proof

Main Specifications:

 

Operation Info

 

Air Suction Cap

1900 CFM

First Stage Filter Micron

30

Second Stage Filter Micron

10

Third Stage Filter Micron

5

Impeller Type

Squirrel Cage

Impeller Size

12 in.

Inlet Hole Diameter

13 in.

Outlet Size

12 in.

Model G0533 (Mfg. Since 3/11)

-3-

Image 5
Contents Model G0533 3HP DRY Spray Booth Page Table of Contents Manual Accuracy Contact Info IntroductionMachine Data Sheet Table Info Identification Safety Instructions for Machinery SafetyUnattended OPERATION. Never­ leave­ Additional Safety Instructions For Dry Spray Booths Power Supply Needed for Set Up SET UPUnpacking QtyHardware and Tools Not Shown InventoryShipping Inventory Figure Qty Hardware Recognition Chart Exhaust Fan To install the exhaust fan housingSite Considerations To install the support bar To install the exhaust fan outletTo install the curtains OutletWork Table To install the work tableDucting To install the filtersFilters To install the air filter indicator Air Filter IndicatorOperations Filter IndicatorTo fill the air filter indicator manometer Dirty filter mark example Interior Booth Walls MaintenanceSchedule Exhaust Fan MotorTroubleshooting Service230V Power Supply G0533 Wiring DiagramMain Parts Breakdown Description Main Parts List36 48 Safety Label Placement and Parts ListModel G0533 Mfg. Since 3/11 Comments Warranty CardBOX BELLINGHAM, WA Grizzly INDUSTRIAL, INCPage Order Hours a DAY