Test Run
The purpose of the test run is to verify that the machine functions properly and is ready for regu- lar operation.
Before beginning this procedure, make sure: (1) you understand the safety instructions at the beginning of this manual, (2) the machine is set up properly, and (3) all tools and objects used dur- ing setup are cleared away from the machine.
IMPORTANT: If the machine or its components do not function as described, or if the machine has unusual noises or vibrations, immediately turn it OFF and disconnect power.
For your convenience, a Troubleshooting table is provided on Page 35. If you cannot find a rem- edy, contact our Tech Support at (570)
To test run the machine:
1.push Emergency Stop button (see Figure 9).
|
|
|
| Elevation | |
| Power/ON |
| Power | ||
| Lamp |
| Feed | ||
|
|
|
|
|
|
|
|
|
|
|
|
| Spindle |
|
| Spindle |
|
| Forward |
|
| Reverse |
|
|
|
|
|
|
|
Spindle
Stop
Emergency Stop
Figure 9. Control panel.
2.rotate Elevation Power Feed switch to OFF.
3.Connect machine to power source by insert- ing power cord plug into matching receptacle.
Model G0755 (Mfg. Since 1/13)
4.twist Emergency Stop button clockwise until it pops
Figure 10. Resetting the switch.
5.Push the Power Lamp/ON button to enable power to the motor—the lamp should light.
6.push Spindle Forward button to start machine. A correctly operating machine runs smoothly with little or no vibration or rubbing noises.
7.press Emergency Stop button to stop machine.
8.WITHOUT resetting Emergency Stop button, press Spindle Forward
The Emergency Stop button safety feature is not working correctly. This safety feature must work properly before proceeding with regular operations. Call Tech Support for help.
9.reset Emergency Stop button and use Elevation Power Feed switch to raise and lower headstock.
The Test Run is complete. Before beginning any regular operations, perform the Spindle