Remington 491 operating instructions Selecting Power Fasteners and Power Loads, Overdrive

Page 13

Selecting Power Fasteners and Power Loads

FASTENING INTO CONCRETE

The proper power fastener length can be determined by adding the thickness of the material to be fastened and the amount of fastener that will actually penetrate the con- crete. The concrete must be three times as thick as the intended fastener penetration. In most cases, penetration should be approximately 1" to 1 1/4" into the base concrete material.

Wood or Non-Metals To Concrete

FASTENING INTO STEEL

The proper fastener length can be determined by adding the thickness of the material to be fastened and the thickness of the steel. The point of the power fastener must go completely through the steel.

482-79

Wood or Non-Metals

To Steel

POWER LOADS

Always start with the lowest power level (green-level 3). If the first test fastener does not penetrate to the desired depth, move to the next highest power level (yellow-level 4). Increase until a proper fastening is made.

IMPORTANT: Damage to the tool will result if the above instructions are not followed (see illustrations to right and lower right).

OVERDRIVEN POWER FASTENERS AND PISTON

An overdriven power fastener results when too strong of a power load is used causing the piston to extend past the muzzle. Move to the next lightest power load. Repeated overdrive will damage your tool. By avoiding overdrive, you can extend the life of your tool considerably and avoid costly repairs.

NOTE: Never fire the tool without a power fastener. This can damage the tool and/or cause possible injury to the operator.

IMPORTANT: Only use 2 1/2" power fasteners with the standard guide. 3" power fasteners can be used with optional guide, part number 301110.

RIGHT

482-66

Flush With Surface

OVERDRIVE

482-67

Piston Extended

Out of Muzzle

099494

13

Image 13 Contents
Powder Actuated Tool RemingtonIndex ? ? Handling the Tool Safety PrecautionsPowd Know Your Fastening Base Material Never make fastenings in spalled or cracked areas Operating the Tool Power Loads and Fasteners GREEN? RED? Unload WHY a Power Fastener Holds Concrete Why a Power Fastener HoldsOverdrive Selecting Power Fasteners and Power LoadsOperation Water Key Part Description Qty Parts ListCleaning and Maintenance Separating Base Plate From Piston Sleeve Removing Rock ARM Removing Rubber PADRemoving Firing PIN Removing Trigger AssemblyRemoving Liner from Tool Body Attaching Trigger Assembly to Tool Body Tool AssemblyAttaching Firing PIN Assembly Attaching Liner to Tool BodyAttaching Rubber PAD Assembling Barrel AssemblyProblem Possible Cause Remedy Troubleshooting GuideFasteners Application ChartSP Fasteners Load Color Code Portable Heater Parts Clark Supply Parts CentralMaintenance Log Canada, Inc Limited Warranty Agreement