Remington 491 operating instructions Water

Page 15

Operation

5.Squeeze trigger to set power fastener. Be sure to keep pressure on tool during this operation.

6.Grasp base plate and slide barrel forward rapidly until it stops. Push base plate back into liner to the closed position. This advances the power load strip and resets the piston for the next fastening.

WARNING: Do not depress muzzle of tool into barrel assembly when loading new power fastener. Live power load is in firing position.

30

WATER

7.Should the tool fail to fire, hold the muzzle firmly against the work surface for 30 seconds. Release the trigger and remove pressure on the tool while holding the muzzle against the work surface. Again press the tool firmly against the work surface and pull the trigger. If the tool still fails to fire, hold the tool firmly against the work surface for another 30 seconds before advancing the power load strip. Use remaining loads in strip. Discard power load strip into water or oil.

099494

15

Image 15 Contents
Powder Actuated Tool RemingtonIndex ? ? Handling the Tool Safety PrecautionsPowd Know Your Fastening Base Material Never make fastenings in spalled or cracked areas Operating the Tool Power Loads and Fasteners GREEN? RED? Unload WHY a Power Fastener Holds Concrete Why a Power Fastener HoldsOverdrive Selecting Power Fasteners and Power LoadsOperation Water Key Part Description Qty Parts ListCleaning and Maintenance Separating Base Plate From Piston Sleeve Removing Rock ARM Removing Rubber PADRemoving Trigger Assembly Removing Firing PINRemoving Liner from Tool Body Attaching Liner to Tool Body Tool AssemblyAttaching Trigger Assembly to Tool Body Attaching Firing PIN AssemblyAttaching Rubber PAD Assembling Barrel AssemblyProblem Possible Cause Remedy Troubleshooting GuideApplication Chart FastenersSP Fasteners Load Color Code Portable Heater Parts Clark Supply Parts CentralMaintenance Log Canada, Inc Limited Warranty Agreement
Related manuals
Manual 28 pages 31.43 Kb