Management Ethernet | One 100/1000 |
connector | management of the enclosure |
| NOTE: The default management port IP addresses for |
| the primary and secondary RAID controller modules |
| are 192.168.128.101 and 192.168.128.102, respectively. |
| By default, the management ports are set to DHCP. |
| If the controller is unable to get an IP address |
| configuration from a DHCP server within a specified |
| time out period (approximately 3 minutes), it defaults |
| back to static IP addressing. For more information, |
| see the Deployment Guide. |
|
|
Expansion |
|
|
|
PowerVault MD1200 series | Supports a maximum of 192 hard drives with any |
| combination of PowerVault MD1200 or PowerVault |
| MD1220 expansion enclosures. Support for 192 hard |
| drives is a Premium Feature and requires activation. |
| The maximum number of hard drives supported |
| without using the Premium Feature is 120. |
| Redundant path connectivity provides redundant |
| data paths to each hard drive. |
|
|
Backplane Board |
|
|
|
Connectors | • 12 or 24 SAS |
| • Two power supply/cooling fan module connectors |
| • Two sets of RAID controller module connectors |
| • One control panel connector for front LEDs and |
| system identification button |
Sensors | Two temperature sensors |
Getting Started With Your System