Carrier 37HS specifications Control Applications, High and Low Pressure Pick-Up Tubes

Page 44

Fig. 35 Ð High and Low Pressure Pick-Up Tubes

BELLOWS PRESSURE Ð As the air¯ow through the unit changes, the high and low pressures vary proportionately. Comparing these 2 pressures, the unit volume controller pro- vides a bellows pressure which in turn in¯ates the unit air valve. Bellows pressure varies from near zero at full ¯ow to plenum or duct pressure at shutoff.

UNIT AIRFLOW DELIVERY Ð The relationship between the bellows pressure and the plenum pressure determines the unit air valve position, which controls unit air¯ow delivery. When the pressures become nearly equal, the valve closes and the unit shuts off. Conversely, as the bellows pressure approaches zero, the valve opens completely and the unit

delivers maximum ¯ow, as determined by the existing ple- num pressure. Units normally operate between these ex- tremes. In constant volume applications, the bellows pres- sure is automatically adjusted in proportion to the plenum pressure, providing a constant pre-set ¯ow within the oper- ating limits of the unit. In variable air volume op- eration, the bellows pressure is further modulated to reduce ¯ow below the preset level as load requirements are satis- ®ed. After passing through the valve, the primary air ¯ows down through the diffuser and out to the conditioned space.

CONTROL APPLICATIONS

Introduction Ð The Moduline terminal is offered with a variety of cooling and heating control options which adapt to many building applications. In this section, the various control applications are described and the functions they in- clude are identi®ed. Each application has a function number which corresponds to the function number shown in Tables 14 and 15 in the Control Selection section, page 50. Table 14 describes the functions; Table 15 shows the control packages required for each function. The part numbers shown are found on the Moduline air terminal price pages.

Detailed operating sequences for each control application are found beginning on page 55.

System-Powered Controls

COMPONENTS OF THE SYSTEM-POWERED CON- TROL SYSTEM Ð The 37HS system-powered control con- sists of a set of custom design and manufacturer's compo- nents which provide air¯ow and temperature regulation of a Moduline air terminal. These devices are interchangeable, ®eld-installed components which plug into the Moduline unit without the use of tools.

Figure 36 shows the basic components: Control block (part of the unit); ®lter/manifold; volume controller; and thermo- stat. Figure 37 demonstrates the control air paths in a sec- tional view of the control system. Note that the high pres- sure and low pressure pick-ups of the unit are connected through the control block to the ®lter and from there to the volume controller and thermostat.

Figure 38 shows the control ®lter/manifold; Fig. 39, the air¯ow volume controller; Fig. 40, the diffuser thermostat with aspirator; and Fig. 41, the wall thermostat and alternate to diffuser mounting.

44

Image 44
Contents Contents IntroductionBuilding Load Calculation 37HS Unit With VAV ControlsEstimating Block Load Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page 35BD Heating Slot Boot Diffuser Director Diffuser Location Guidelines Terminal Selection LayoutOptimum Outlet Discharge Single Moduline Unit Connected to Supply Duct Recommended Maximum Cfm Per Terminal Diffuser Locations for Preferred 2-Way or One-Way BlowAir Throw Data Ð Way and 1-Way Director, 3-Slot Diffusers Consider Unit Combinations And Run Run-Out Duct for Single Moduline Unit 37HS1 Units in Air Series 37HS1 Units in Air Series 37HS2 Units in Air Series 37HS2 Units in Air Series 37HS4 Units in Air Series 37HS4 Units in Air Series Air Series of Units with Different Capacities Air Series of Units of the Same Size and Capacity Additional DP for Flexible Duct with 90-Degree Bend Units in Adjoining ModulesFlexible Duct Used with 90-Degree Bend Maximum Number of Units in an Air Series on One ControllerLocation of Volume Controller On Single Unit Incorrect Layout of Moduline Units with Controls Corrected Layout Moduline Valve Shows the internal components of the Moduline unitBellows and Unit Air Valve Arrangement Cross Section of 37HS Moduline Air Terminal Control Applications High and Low Pressure Pick-Up Tubes37HS Control Components Wall-Mounted Thermostat Constant Volume Control Arrangement Cooling/Heating Wall Thermostat VAV Control Arrangement with Electric Heat Interlock Control Selection Control Index37HS Control Combinations Heating & Cooling Electric Changeover HEATING/COOLING Control Operating Sequences Variable Volume Controls Schematic Page Page Page Location of CV Unit for Warm-Up Application Page Page Page System-Powered Controls with Electric Interface Page Page Page Connection for Electric Interlock System-Powered Controls with Pneumatic Interface Piping Diagram, no Conguration Pneumatic Warm-Up Airflow Adjustment Maximum Air¯ow SettingsHK08ZZ030 Multiple Unit Air¯ow VariationAIR Distribution Moduline Diffuser Mixing Room Air and Primary AirTypical Room Air Distribution Pattern Slot Openings in Standard and Optional Diffusers Standard Diffusers for 37HS1 Standard Diffusers for 37HS2 Standard Diffusers for 37HS4 Optional Diffusers for 37HS1 Model TypeOptional Diffusers for 37HS2 Optional Diffusers for 37HS4 Air Throw Data Ð Way and 2-Way Blow, 2-Slot Diffusers Page Copyright 1991 Carrier Corporation

37HS specifications

The Carrier 37HS is a cutting-edge heating, ventilation, and air conditioning (HVAC) solution designed to deliver exceptional performance and energy efficiency for residential and commercial applications. This unit is particularly favored for its advanced features and reliable operation, making it a popular choice among homeowners and building managers alike.

One of the standout characteristics of the Carrier 37HS is its high Seasonal Energy Efficiency Ratio (SEER), which indicates its ability to provide effective cooling while minimizing energy consumption. This makes it not only cost-effective but also an environmentally-friendly choice, helping to reduce the overall carbon footprint. The unit is equipped with state-of-the-art inverter technology, which allows it to adjust its cooling capacity to match the current demand, thus enhancing comfort while optimizing energy use.

The Carrier 37HS incorporates a high-efficiency scroll compressor that operates quietly and efficiently. This technology enhances the unit's reliability and longer service life while ensuring minimal noise levels during operation, making it suitable for residential settings where tranquility is paramount.

A significant feature of the 37HS is its variable-speed fan system, which enables gradual adjustments in airflow to maintain a consistent and comfortable indoor environment. This not only contributes to enhanced comfort but also reduces wear and tear on the system, further extending its longevity.

Moreover, the Carrier 37HS is designed with advanced air filtration capabilities, utilizing multi-stage filters that capture airborne particles, allergens, and pollutants. This results in improved indoor air quality, making it an ideal choice for those with allergies or respiratory issues.

The unit also boasts user-friendly smart controls, allowing homeowners to monitor and adjust settings remotely via a smartphone app. This feature adds convenience and assists in energy management, ensuring that users can optimize their HVAC system even when they are away from home.

In summary, the Carrier 37HS stands out for its exceptional energy efficiency, quiet operation, advanced technology, superior air filtration, and modern smart controls. These features collectively make it a prime solution for those seeking a reliable HVAC system that delivers both comfort and savings, while also contributing positively to environmental sustainability. Whether for a residential setting or a commercial establishment, the Carrier 37HS is engineered to meet a variety of climate control needs with excellence.