6/11/03 | 7:56 AM | Page 6 | ||
F GB | D E | I | P | NL S DK N FIN GR H CZ RUS RO PL SLO HR TR |
English
RULES FOR SAFE OPERATION
■If under abusive conditions, liquid is ejected from the battery, avoid contact. If this accidentally occurs, flush with water. If liquid contacts eyes additionally, seek medical help.
■Do not place battery tools or their batteries near fire or heat. This will reduce the risk of explosion and possibly injury.
WARNING
Batteries vent hydrogen gas and can explode in the presence of a source of ignition, such as a pilot light. To reduce the risk of serious personal injury, never use any cordless product in the presence of open flame. An exploded battery can propel debris and chemicals. If exposed, flush with water immediately.
SPECIFICATIONS
Model |
| |
Voltage | 18 V | |
Chuck | 13 mm | |
Switch | Variable speed | |
No load speed (drill mode): |
|
|
- Lo speed | 0 | - 370 |
- Hi speed | 0 | - 750 |
- | 0 | - 2200 |
No load speed (impact mode): |
|
|
- Lo speed | 0 | - 5920 |
- Hi speed | 0 | - 12000 |
- | 0 | - 35200 |
Max. Torque | 55 Nm | |
Weight - incl. battery pack | 3 kg | |
Battery pack (not included): | ||
Charger (not included) |
FEATURES
1.Keyless chuck
2.Switch trigger
3.Direction of rotation selector (Forward/Reverse)
4.Screwdriver bits
5.Battery pack (not included)
6.Depth gauge Rod
7.Auxiliary handle
8.Latches
9.Depress latches to release battery pack
10.To Tighten
11.To Loosen
12.Drilling Depth
13.To Decrease torque
14.To Increase torque
15.Torque adjusting Ring
16.Drill mode
17.Impact mode
18.Forward / Reverse selector
19.Reverse
20.Forward
21.Unlock (release)
22.Chuck jaws
23.Lock (tighten)
OPERATION
TO INSTALL BATTERY PACK (NOT INCLUDED)
■Lock switch trigger on your drill by placing the direction of rotation selector in center position. See Figure 6.
■Place battery pack in your drill. Align raised rib on battery pack with groove inside drill. See Figure 2.
■Make sure the latches on battery pack snap in place and battery pack is secured in drill before beginning operation.
TO REMOVE BATTERY PACK (NOT INCLUDED)
■Lock switch trigger on your drill by placing the direction of rotation selector in center position. See Figure 6.
■Locate latches of battery pack and depress to release battery pack from your drill. See Figure 2.
■Remove battery pack from your drill.
ADJUSTING THE AUXILIARY HANDLE
See Figure 3.
Follow these steps to adjust the auxiliary handle.
■Loosen the auxiliary handle by turning the knob counterclockwise.
■Rotate the auxiliary handle to the desired location.
■Tighten the auxiliary handle securely by turning the knob clockwise.
ADJUSTING THE DEPTH GAUGE ROD
See Figure 4.
Follow these steps to adjust the depth gauge rod.
■Lock the trigger switch by placing the rotation selector in the center position.
■Loosen the auxiliary handle by turning the knob counterclockwise.
6