SECTION 2 – INSTALLATION
2-1. Specifications
|
| Max. OpenCir- | Amps Input at Rated Output, 60 Hz, |
| |||||
|
|
|
|
|
|
|
| ||
Rated Output | cuit Voltage | 200 V | 230 V | 460 V | 575 V | KVA | KW | ||
|
|
|
|
|
|
|
|
| |
250 A at 28 VDC, | 200 A at 28 VDC, | 32 | 50 | 44 | 22 | 18 | 10 | 7.7 | |
40% Duty Cycle | 60% Duty Cycle |
| 2.3* | 2* | 1* | 0.8* | 0.46* | 0.13* | |
|
|
|
|
|
|
|
|
| |
| Wire Type and Diameter |
| Wire Feed Speed | Dimensions | Weight | ||||
|
|
|
|
|
| ||||
Solid Steel | Stainless Steel | Flux Cored | H: | 198 lb | |||||
|
|
|
| W: | (89 kg) | ||||
.023 | .023 | .030 | |||||||
|
| D: |
| ||||||
(0.6 – 1.2 mm) | (0.6 – 0.9 mm) | (0.8 – 1.2 mm) |
|
|
| ||||
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
* While idling
2-2. Welding Power Source Duty Cycle And Overheating
Duty Cycle is percentage of 10 min- utes that unit can weld at rated load without overheating.
If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or voltage, or duty cycle before welding.
Y Exceeding duty cycle can damage unit and void warranty.
60% Duty Cycle At 200 Amperes
6 Minutes Welding | 4 Minutes Resting |
40% Duty Cycle At 250 Amperes
4 Minutes Welding | 6 Minutes Resting |
Overheating
0
A or V
15
OR
Reduce Duty Cycle
Minutes
duty1 4/95 –