4-9. Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

Trouble

 

 

Remedy

 

 

No weld output; wire does not feed.

Be sure line disconnect switch is On (see Section 2-13).

 

 

 

 

 

Replace building line fuse or reset circuit breaker if open (see Section 2-13).

 

 

 

 

 

Reset circuit breaker CB1 (see Section 4-2).

 

 

 

 

 

Secure gun trigger connections (see Section 2-6).

 

 

 

 

 

Check and replace Power switch if necessary.

 

 

 

 

 

Have Factory Authorized Service Agent check all board connections and main control board.

 

 

No weld output; wire feeds.

Thermostat TP1 open (overheating). Allow fan to run; the thermostat will close when the unit has cooled

 

 

(see Section 2-2).

 

 

 

 

 

Connect work clamp to get good metal to metal contact.

 

 

 

 

 

Replace contact tip (see section 4-6).

 

 

 

 

 

An overload condition occurred. Release gun trigger (see Section 4-3).

 

 

 

 

 

Have Factory Authorized Service Agent check main control board and main rectifier.

 

 

Low weld output.

Connect unit to proper input voltage or check for low line voltage (see Section 2-13).

 

 

 

 

 

Check input voltage jumper links and correct position if necessary (see Section 2-10).

 

 

 

 

 

Have Factory Authorized Service Agent check main control board.

 

 

Fan motor does not run. NOTE: Fan only

Have Factory Authorized Service Agent check fan-on-demand circuit.

runs when cooling is necessary.

 

 

 

 

 

Low, high, or erratic wire speed.

Readjust front panel settings (see Section 3-1).

 

 

 

 

 

Change to correct size drive rolls (see Section 4-4).

 

 

 

 

 

Readjust drive roll pressure (see Section 2-14).

 

 

 

 

 

Replace inlet guide, contact tip, and/or liner if necessary (see sections 4-6 and/or 4-7).

 

 

 

 

 

Check position of input jumper links (see Section 2-10).

 

 

 

 

 

Have Factory Authorized Service Agent check main control board.

 

 

No wire feed.

Reset circuit breaker CB1 (see Section 4-2).

 

 

 

 

 

Turn Wire Speed control to higher setting (see Section 3-1).

 

 

 

 

 

Clear obstruction in gun contact tip or liner (see sections 4-6 and/or 4-7).

 

 

 

 

 

Readjust drive roll pressure (see Section 2-14).

 

 

 

 

 

Change to correct size drive rolls (see Section 4-4).

 

 

 

 

 

Rethread welding wire (see Section 2-14).

 

 

 

 

 

Check gun trigger and leads. Repair or replace gun if necessary.

 

 

 

 

 

Have Factory Authorized Service Agent check main control board.

 

 

Poor weld bead, or welding

Check polarity setting for type of welding wire being used (see Section 2-7).

wire is noodle welding.

 

 

 

 

 

 

 

 

OM-194 430 Page 24

Image 28
Contents OM-194 430A ProcessesDescription JunePage Table of Contents Page Symbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersSignification des symboles Consignes DE Securite Lire Avant UtilisationUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un incendie ou une explosionLE Bruit peut affecter l’ouïe Risque D’INCENDIE OU LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresInformation sur les champs é lectromagné tiques Principales normes de sé curitéConsignes relatives aux stimulateurs cardiaques Installation SpecificationsWelding Power Source Duty Cycle And Overheating Exceeding duty cycle can damage unit and void warrantyVolt-Ampere Curves Welding Gun Duty Cycle And OverheatingDefinition Installing Running Gear Installing Welding GunSetting Gun Polarity For Wire Type Installing Gas Supply Installing Wire Spool And Adjusting Hub TensionInstalling Work Clamp Positioning Jumper LinksElectrical Service Guide Selecting a Location And Connecting Input PowerInput Voltage Min Grounding Conductor Size In AWG/KcmilThreading Welding Wire Hold wire tightly to keep it from unravelingOperation ControlsWeld Parameters CO2Knockout Panel Maintenance and Troubleshooting Routine MaintenanceDisconnect power before maintaining Circuit Breaker CB1Changing Drive Roll And Wire Inlet Guide Aligning Drive Rolls And Wire GuideUnit Overload Replacing Gun Contact TipTurn off welding power source/wire feeder Wire size stamped on tip check and match wire sizeReplacing Switch And/Or Head Tube Disconnect gun firstTroubleshooting Trouble RemedyElectrical Diagram Circuit Diagram For Welding Power SourceOM-194 430 Parts List Main AssemblyItem Dia Part Description Mkgs Quantity Center Baffle w/Components Center Baffle w/Components -1 Item Wire Drive Assembly -2 Item Gun And Cable Assembly, M-25 Part Description Quantity Options and Accessories Page File a claim for loss or damage during ship Ment