3-12. 115 VAC/Contactor Control Plug Information
J | A |
I | K |
| B |
H | N L C |
GM D
F E
2
1 Interconnecting Cord
2 115 VAC/Contactor Control
Plug PLG5
If CC or CC/CV welding power source is equipped with matching
If plug PLG5 will not connect to CC welding power source receptacle, use the following pin information and Section
1
| Pin* | Pin Information |
|
|
|
|
|
|
| A, B | Contact closure to A completes contactor control circuit. |
Remote | I | 115 volts ac. |
Contactor | J | Contact closure to I completes 115 volts ac contactor control circuit. |
| ||
| G | Circuit common for 115 volts ac circuit. |
|
|
|
| C | +10 volts dc output to remote control. |
Remote | D | Remote control circuit common. |
|
| |
Voltage Control | E | 0 to +10 volts dc input command signal from remote control. |
| K | Chassis common. |
|
|
|
*The remaining pins are not used.
Ref.