Hobart Welding Products TM-944C manual Troubleshooting Table

Page 22

SECTION 6 − TROUBLESHOOTING

6-1. Troubleshooting Table

 

 

 

 

 

 

 

 

. See Section 6-2or 6-3for test points and values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and Section 9 for parts location.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble

 

 

 

 

Remedy

 

 

 

 

No weld output; wire does not feed; fan

Secure power cord plug PLG1 in receptacle (see Section 3-6or 3-7).

 

does not run.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace building line fuse or reset circuit breaker if open.

 

 

 

 

 

 

 

 

 

Place Power switch S1 in On position (see Section 4-1).

 

 

 

 

 

 

 

 

 

Reset power source circuit breaker if open (see Section 7-2).

 

 

 

 

No weld output; wire does not feed; fan

Rotate Voltage switch S2 out of the Purge (gas only) position.

 

runs.

 

 

 

 

 

 

Thermostat TP1 open (overheating). Allow fan to run; the thermostat will close when the unit has

 

 

 

 

 

 

 

 

cooled (see Section 7-3).

 

 

 

 

 

 

 

 

 

Secure gun trigger leads to receptacle RC3 (see Section 3-1).

 

 

 

 

 

 

 

 

 

Check continuity of gun trigger leads. Repair or replace gun if necessary.

 

 

 

 

 

 

 

 

 

Check Wire Speed control R1 for proper connections and resistance; R1 is 55k ohms ±20%.

 

 

 

 

Replace R1 if necessary.

 

 

 

 

 

 

 

 

 

Check continuity of Voltage switch S2, and replace if necessary.

 

 

 

 

 

 

 

 

 

Check diodes in main rectifier SR1, and replace if necessary.

 

 

 

 

 

 

 

 

 

Check main transformer T1 for signs of winding failure. Check continuity across windings and check for

 

 

 

 

proper connections. Check secondary voltages. Replace T1 if necessary.

 

 

 

 

 

 

 

 

 

Check control board PC1 connections and voltages, and replace if necessary.

 

 

 

 

 

 

 

 

 

Check the setting of Voltage switch S2. Machine will not weld if voltage control is set between range

 

 

 

 

positions. Rotate switch until it “clicks” into a detent position.

 

 

 

 

Electrode wire feeding stops during

Straighten gun cable and/or replace damaged parts (see Section 7-6).

 

welding.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Readjust drive roll pressure (see Section 3-10).

 

 

 

 

 

 

 

 

 

Change to proper groove (see Section 7-4).

 

 

 

 

 

 

 

 

 

Readjust wire reel hub tension (see Section 3-9).

 

 

 

 

 

 

 

 

 

Replace contact tip if blocked (see Section 7-5).

 

 

 

 

 

 

 

 

 

Clean or replace wire inlet guide or liner if dirty or plugged (see Section 7-4and/or 7-6).

 

 

 

 

 

 

 

 

 

Replace drive roll or pressure bearing if worn or slipping (see Section 7-4).

 

 

 

 

 

 

 

 

 

Secure gun trigger leads in receptacle RC3 (see Section 3-1).

 

 

 

 

 

 

 

 

 

Check continuity of gun trigger leads. Repair or replace gun if necessary.

 

 

 

 

 

 

 

 

 

Check and clear any restrictions at drive assembly and liner (see Section 3-10and/or 7-6).

 

 

 

 

 

 

 

 

 

Release gun trigger and allow gun and motor protection circuitry to reset.

 

 

 

 

 

 

 

 

 

Check T1 for signs of winding failure. Check continuity across each winding and check for proper

 

 

 

 

connections. Check secondary voltages. Replace T1 if necessary.

 

 

 

 

 

 

 

 

 

Check Control board PC1 and connections, and replace PC1 if necessary (see Section 6-4).

 

 

 

 

 

 

 

 

 

TM-944 Page 20

Return To Table Of Contents

Handler 135 / 175

Image 22
Contents Processes TM-944CDescription Table of Contents Symbol Usage − Safety Precautions for ServicingServicing Hazards Radiation can cause interference California Proposition 65 WarningsEMF Information Overuse can cause OverheatingSpecifications − SpecificationsVAC Model Duty Cycle % Duty Cycle And OverheatingOutput Output AmperesVolt-Ampere Curves − Installation Installing Welding Gun Installing Work ClampProcess/Polarity Table Electrode Negative For Flux Core WireFor Solid Wire Changing PolarityInstalling Gas Supply Volt, 20 ampere individual Rating LabelGrounded Receptacle Up to 200 ft 61 m= GND/PE Do not move or operate unit where it could tip18 in 457 mm of space for airflow L2 L1 230 VAC230 Electrical Service Guide For 230 VAC ModelInstalling Wire Spool And Adjusting Hub Tension Reference 1996 National Electrical Code NECBe sure that tip matches wire diameter Threading Welding WirePressure Indicator Scale Reinstall contact tip and nozzle− Operation Voltage SwitchPower Switch ControlsWeld Parameter Chart For 115 VAC Model Electrode Positive For Solid Wire Starting Value only − Wire Speed Setting Can beWire Speed Also Depends on Other variables Such Stick Out WhileWeld Parameter Chart For 230 VAC Model Listed Starting Value Only − Wire Speed Setting can be Metal Etc− Theory of Operation Main Block Wire Drive MotorStablizer L1 Polarity− Troubleshooting Troubleshooting TableGS1 if necessary Clear blockage in gunV8/R5 V9/R6 V10 V11/R9 TM-944Or Flux Core 030/.035 Solid585 640Test Equipment Needed Handler 135600 510700 Control Board PC1 Testing Information 115 VAC Model Control Board PC1 Test Point Values 115 VAC Model Circuit commonControl Board PC1 Testing Information 230 VAC Model Control Board PC1 Test Point Values 230 VAC Model Disconnect power before maintaining − MaintenanceRoutine Maintenance Overload Protection Drive Motor ProtectionTurn Off power before replacing contact tip Changing Drive Roll Or Wire Inlet GuideReplacing Gun Contact Tip Disconnect gun from unit Cleaning Or Replacing Gun LinerTo Reassemble Gun Replacing Switch And/Or Head Tube − Electrical Diagrams Model Serial Or Style Number Circuit Diagram Wiring Diagram194 324-C 194 325-A 196 637-A 196 655-A 195 890-A 195 891-A Handler 135 H-10 Gun − Parts List 11 10Dia Part Mkgs Description Quantity Optional Options Optional Drive Rolls195 Hobart Welding Products