Hobart Welding Products OM-947 California Proposition 65 Warnings, Principal Safety Standards

Page 8

1-4. California Proposition 65 Warnings

Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.)

Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

This product contains chemicals, including lead, known to the state of California to cause cancer, birth defects, or other reproductive harm. Wash hands after use.

1-5. Principal Safety Standards

Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

Safe Practices for the Preparation of Containers and Piping for Welding and Cutting, American Welding Society Standard AWS F4.1, from Glob- al Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

National Electrical Code, NFPA Standard 70, from National Fire Protec- tion Association, Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org and www. sparky.org).

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 4221 Walney Road, 5th Floor, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).

Safety in Welding, Cutting, and Allied Processes, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 5060 Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (phone: 800-463-6727, website: www.csa-international.org).

Safe Practice For Occupational And Educational Eye And Face Protec- tion, ANSI Standard Z87.1, from American National Standards Institute,

For Gasoline Engines:

Engine exhaust contains chemicals known to the State of California to cause cancer, birth defects, or other reproduc- tive harm.

For Diesel Engines:

Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.

25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, web-

site: www.ansi.org).

Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, NFPA Standard 51B, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org.

OSHA, Occupational Safety and Health Standards for General Indus- try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Super- intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954 (phone: 1-866-512-1800) (there are 10 OSHA Regional Offices— phone for Region 5, Chicago, is 312-353-2220, website: www.osha.gov).

U.S. Consumer Product Safety Commission (CPSC), 4330 East West Highway, Bethesda, MD 20814 (phone: 301-504-7923, website: www.cpsc.gov).

Applications Manual for the Revised NIOSH Lifting Equation, The Na- tional Institute for Occupational Safety and Health (NIOSH), 1600 Clifton Rd, Atlanta, GA 30333 (phone: 1-800-232-4636, website: www.cdc.gov/NIOSH).

1-6. EMF Information

Electric current flowing through any conductor causes localized electric and magnetic fields (EMF). Welding current creates an EMF field around the welding circuit and welding equipment. EMF fields may inter- fere with some medical implants, e.g. pacemakers. Protective measures for persons wearing medical implants have to be taken. For example, access restrictions for passers−by or individual risk assess- ment for welders. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:

1.Keep cables close together by twisting or taping them, or using a cable cover.

2.Do not place your body between welding cables. Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep head and trunk as far away from the equipment in the welding circuit as possible.

5.Connect work clamp to workpiece as close to the weld as possible.

6.Do not work next to, sit or lean on the welding power source.

7.Do not weld whilst carrying the welding power source or wire feeder.

About Implanted Medical Devices:

Implanted Medical Device wearers should consult their doctor and the device manufacturer before performing or going near arc welding, spot welding, gouging, plasma arc cutting, or induction heating operations. If cleared by your doctor, then following the above procedures is recom- mended.

OM-947 Page 4

Image 8
Contents File Flux Cored Fcaw ProcessesDescription From Hobart to You Protect Your InvestmentTable of Contents Warranty Symbol Usage Arc Welding Hazards Electric Shock can kill HOT Parts can burnFumes and Gases can be hazardous ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal or Dirt can injure eyesWelding Wire can injure Fire or Explosion hazardFalling Equipment can injure Moving Parts can injurePrincipal Safety Standards California Proposition 65 WarningsEMF Information About Implanted Medical DevicesSymboles utilisés UNE Décharge Électrique peut entraîner la mortLE Soudage peut provoquer un incendie ou une explosion LES Pièces Chaudes peuvent provoquer des brûluresLES Fumées ET LES GAZ peuvent être dangereux LE Bruit peut endommager l’ouïe LES Bouteilles peuvent exploser si elles sont endommagéesRisque D’INCENDIE OU LA Chute DE L’ÉQUIPEMENT peut provoquer des blessuresProposition californienne 65 Avertissements Les Pièces Mobiles peuvent causer des blessuresLES Fils DE Soudage peuvent provoquer des blessures LE Soudage À L’ARC risque de provoquer des interférencesEn ce qui concerne les implants médicaux Principales normes de sécuritéInformations relatives aux CEM OM-947 − Specifications Symbols And DefinitionsSpecifications − DefinitionsDuty Cycle And Overheating Volt-Ampere CurvesTools Needed Slide insulating grips over handles OM-947 − InstallationInstalling Work Clamp Process/Polarity Table Changing PolarityInstalling Gas Supply Tools Needed 11/16, 1-1/8 Shielding GasInstalling Wire Spool And Adjusting Hub Tension Tools NeededSerial Number And Rating Label Location 460 mmInstalling Contact Tip And Nozzle Turn off welding power sourceThreading Welding Wire − Operation ControlsOperating The Gun LoadOM-947 Weld Parameter Chart 210 − Maintenance &TROUBLESHOOTING Routine MaintenanceOverload Protection Drive Motor ProtectionChanging Drive Roll Or Wire Inlet Guide Turn Off power before replacing contact tip Replacing Gun Contact TipCleaning Gun Liner Loosen liner setscrew Replacing Gun LinerHead Mm / 10 mm Tube 10 mm Troubleshooting Table Secure power cord plug in receptacle see SectionPower source see Section Trouble Remedy− Electrical Diagram Circuit DiagramTypical MIG Process Connections − Wire Welding GuidelinesTypical Fcaw Process Connections Typical Control Settings Wire Size Amperage RangeAmperage Select VoltageHolding And Positioning Welding Gun Groove WeldsSlow Normal Fast Conditions That Affect Weld Bead ShapeShort Normal Long Gun Movement During Welding Poor Weld Bead CharacteristicsGood Weld Bead Characteristics Troubleshooting − Excessive Spatter Troubleshooting − PorosityTroubleshooting − Excessive Penetration Possible Causes Corrective ActionsTroubleshooting − Burn-Through Troubleshooting − Lack Of PenetrationTroubleshooting − Incomplete Fusion Troubleshooting Guide For Semiautomatic Welding Equipment Troubleshooting − Waviness Of BeadTroubleshooting − Distortion − Parts List Main AssemblyOptional 195 157R − See TablePkg PkgWeatherproof Nylon 195 Hub Kit For 8 in Wire Spool209 Work like a Pro Page Page Assistance ServiceSupport Contact your Distributor for Hobart Welding Products