GE Essential Guide for Dust Collector Communication Settings

Page 16

RS485 INTERFACE (MODBUS RTU)

 

 

 

 

 

COMMUNICATIONS GUIDE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Modbus

 

Hex

Description

Min

Max

Step

Units

Format

Default

Size in

 

 

 

 

 

 

 

 

 

 

 

 

Words

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30210

 

00D1

Pre Trip Vcn

---

---

---

V

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30211

 

00D2

Pre Trip System Frequency

---

---

---

Hz

F3

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30212

 

00D3

Pre Trip Real Power

---

---

---

kW

F13

N/A

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30214

 

00D5

Pre Trip Reactive Power

---

---

---

kvar

F13

N/A

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30216

 

00D7

Pre Trip Apparent Power

---

---

---

kVA

F2

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30217

 

00D8

Pre Trip Power Factor

---

---

---

---

F21

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30218

 

00D9

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30222

 

00DD

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

REAL-TIME CLOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30223

 

00DE

Weekday

---

---

---

---

FC171

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30224

 

00DF

Date Read Only

---

---

---

---

F18

N/A

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30226

 

00E1

Time Read Only

---

---

---

---

F19

N/A

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30228

 

00E3

Daylight Savings Active

---

---

---

---

FC126

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30229

 

00E4

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

TRIP COUNTERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30230

 

00E5

Total Number of Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30231

 

00E6

Incomplete Sequence Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30232

 

00E7

Overload Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30233

 

00E8

Mechanical Jam Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30234

 

00E9

Undercurrent Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30235

 

00EA

Current Unbalance Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30236

 

00EB

Ground Fault Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30237

 

00EC

Motor Acceleration Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30238

 

00ED

Undervoltage Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30239

 

00EE

Overvoltage Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30240

 

00EF

Voltage Phase Reversal Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30241

 

00F0

Voltage Freq Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30242

 

00F1

Underpower Trips

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30243

 

00F2

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30256

 

00FF

Reserved

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL TIMERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30257

 

0100

Number of Motor Starts

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30258

 

0101

Number of UV Restarts

---

---

---

---

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30259

 

0102

Motor Running Hours

---

---

---

hrs

F9

N/A

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30261

 

0104

UVR Timer

---

---

---

s

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30262

 

0105

Start Timer 1

---

---

---

s

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30263

 

0106

Start Timer 2

---

---

---

s

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30264

 

0107

Start Timer 3

---

---

---

s

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30265

 

0108

Start Timer 4

---

---

---

s

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30266

 

0109

Start Timer 5

---

---

---

s

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30267

 

010A

TransferTimer

---

---

---

s

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30268

 

010B

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30269

 

010C

Motor Stopped Hours

---

---

---

hrs

F1

N/A

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

START BLOCKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

MM300 MOTOR MANAGEMENT SYSTEM – COMMUNICATIONS GUIDE

Image 16
Contents MM300 Page Table of Contents MM300 Motor Management System Communications Guide MM300 Motor Management System Communications Guide Data Frame Format and Data Rate Electrical InterfaceData Packet Format Error Checking CRC-16 AlgorithmMM300 supported functions TimingFunction Code 03H Function Code 04H Master/slave packet format for function code 03HMaster Transmission Bytes Example Description Slave Response Bytes Example DescriptionMaster/slave packet format for function code 04H Function Code 05HMaster/slave packet format for function code 05H Function Code 06H Master/slave packet format for function code 06HData CRC CB B9Function code 7 bitmask Function Code 07HMaster/slave packet format for function code 07H Function Code 08H Function Code 10HMaster/slave packet format for function code 08H Diag CodeError Responses Master/slave packet format for function code 10HModbus memory map Actual ValuesREAL-TIME Clock General TimersTrip Counters CONTACT/VIRTUAL INPUTS/OUTPUTS Status SecurityStatus Motor Current MeteringPower Metering FLA RTD Maximium Temperature Motor Starting Learned DataGCP Factory Test User MAP ValuesEvent Recorder Status BufferSetpoints Commands Communication SettingsFlexlogic CommunicationREAL-TIME CLOCK/DAYLIGHT Savings Current SensingVoltage Sensing Motor Data SetupProcess Interlock RS485 Interface Modbus RTU Open Control Circuit Communication SetupUser MAP Addresses Reset Setup Mechanical JAMRTD OPEN/SHORT Circuit REQUIRED=IOG Thermistor CPUUnderpower IOA + IOC or IOA + IOB Ground FaultUndercurrent REQUIRED=IOA FLAPhase Undervoltage REQUIRED=IOB Phase Overvoltage REQUIRED=IOBPhase Reversal REQUIRED=IOB Load IncreaseMaintenance Flexlogic TimersStart Inhibit Restart BlockCommunications Guide RS485 Interface Modbus RTU Communications Guide RS485 Interface Modbus RTU Contact Input Assignment Contact Outputs Auto / Manual ControlFlexlogic Equation Unsigned Value Unsigned VALUE, 1 Decimal PlaceUnsigned VALUE, 2 Decimal Places Unsigned Long ValueUnsigned Long VALUE, 3 Decimal Places Date MM/DD/YYYYMSB LSBOn / YES OFF / noOFF USER2 USER1USER3 No Event/Trip To Date RS485 Interface Modbus RTU RS485 Interface Modbus RTU Not XOR Latch NOR Nand Timer Assign RS485 Interface Modbus RTU Definition RS485 Interface Modbus RTU SUN MONTUE WEDVbn Direct Bit FC180 FC181 FC182 FC183 RS485 Interface Modbus RTU Performing Commands Using Function Code 10H Master/slave packet format for performing commands Using the User Definable Memory MapCRC 7E CE RS485 Interface Modbus RTU Ethernet interface Profibus Output Data Fieldbus interface external connections ProfibusProfibus LED indications LEDProfibus DP-Diagnostics System Standard Diagnostics Bytes 1 throughProfibus Input Data F1BCommunications Guide Fieldbus Interface DeviceNet Communications Fieldbus interface external connections DeviceNetDeviceNet LED indications Class ObjectMessage Router Class Code 02H Identity Object Class Code 01HDeviceNet Object Class Code 03H Connection Object, Class Code 05h, Services Attribute Access Name Data Type Value DescriptionDeviceNet Connection Object Class Code 05H Identity Object, Class Code 03h, Instance 01h, AttributesDeviceNet Motor Data Poll, Explicit Object Class Code A0H Motor Data Object, Class Code A0h, ServicesMotor Data Object, Class Code A0h, Attributes Item Description Size in Bytes Format Attribute Description Size in Bytes Explicit Motor Analog Data Object, Class Code B0h, Services0FH Data Formats, Explicit Motor Analog Data Object Attribute Item Description Size Format BytesFieldbus Interface Explicit Motor Control Object, Class Code B1h, Services DeviceNet Explicit Motor Object, Class Code B1HExplicit Motor Control Object, Class Code B1h, Attributes Data Value, Class B1hFieldbus Interface

MM300 specifications

The GE MM300 is a robust and versatile controller designed primarily for industrial automation applications. Built to tackle the demands of modern manufacturing environments, this controller offers a range of features that contribute to its popularity among engineers and operators.

One of the standout features of the GE MM300 is its scalability. The device can be easily configured to meet the needs of both small and large systems. Its modular architecture allows users to add or remove components based on the specific requirements of their applications, facilitating a more tailored approach to automation.

The MM300 supports various communication protocols, including Ethernet/IP, Modbus TCP, and more, ensuring seamless integration with a variety of devices and systems. This feature significantly enhances interoperability, allowing users to connect the controller to existing infrastructure without extensive reconfiguration.

In terms of processing power, the MM300 is equipped with a high-performance processor that can handle complex tasks with ease. With advanced data handling capabilities, it supports real-time data processing, enabling faster decision-making and improving overall operational efficiency. This capability is particularly beneficial for applications requiring precise control and monitoring.

Moreover, the GE MM300 boasts a user-friendly interface, featuring an intuitive programming environment that simplifies the development of control applications. This includes an integrated development environment (IDE) and support for popular programming languages, making it accessible for both seasoned programmers and those new to automation technologies.

The device is designed to operate in challenging industrial conditions, featuring a rugged construction that ensures durability and longevity. Its ability to withstand extreme temperatures, vibrations, and other environmental stressors enhances its reliability in demanding applications, which is crucial for minimizing downtime in production processes.

Security is another critical aspect of the GE MM300. The controller incorporates advanced security features to protect against unauthorized access and cyber threats, helping organizations ensure the integrity of their operations.

In summary, the GE MM300 stands out due to its scalability, versatile communication options, high processing capabilities, user-friendly programming environment, rugged design, and security features. These characteristics make it a reliable choice for industries seeking to enhance their automation processes and improve overall efficiency. Whether for small-scale or large-scale applications, the MM300 provides a comprehensive solution to meet the evolving needs of modern manufacturing.