RS485 INTERFACE (MODBUS RTU)

 

COMMUNICATIONS GUIDE

 

 

 

 

 

Code

Type

Definition

 

 

 

 

 

 

 

 

 

0xC000

 

Control

 

 

 

 

 

FC143

16 bits

Drive Status

 

0

 

Drive Unavailable

 

 

 

 

 

1

 

Available Auto

 

 

 

 

 

2

 

Available Manual

 

 

 

 

 

3

 

Available

 

 

 

 

 

4

 

Running

 

 

 

 

 

FC144

32 bits

LED Status

 

Bit 0

 

Running Red

 

 

 

 

 

Bit 1

 

Running Green

 

 

 

 

 

Bit 2

 

Stopped Red

 

 

 

 

 

Bit 3

 

Stopped Green

 

 

 

 

 

Bit 4

 

Tripped Red

 

 

 

 

 

Bit 5

 

Tripped Green

 

 

 

 

 

Bit 6

 

Alarm Red

 

 

 

 

 

Bit 7

 

Alarm Green

 

 

 

 

 

Bit 8

 

Auto Red

 

 

 

 

 

Bit 9

 

Auto Green

 

 

 

 

 

Bit 10

 

Manual Red

 

 

 

 

 

Bit 11

 

Manual Green

 

 

 

 

 

Bit 12

 

Comms OK Red

 

 

 

 

 

Bit 13

 

Comms OK Green

 

 

 

 

 

Bit 14

 

USER1 Red

 

 

 

 

 

Bit 15

 

USER1 Green

 

 

 

 

 

Bit 16

 

USER2 Red

 

 

 

 

 

Bit 17

 

USER2 Green

 

 

 

 

 

Bit 18

 

USER3 Red

 

 

 

 

 

Bit 19

 

USER3 Green

 

 

 

 

 

Bit 20

 

50% Red

 

 

 

 

 

Bit 21

 

50% Green

 

 

 

 

 

Bit 22

 

80% Red

 

 

 

 

 

Bit 23

 

80% Green

 

 

 

 

 

Bit 24

 

100% Red

 

 

 

 

 

Bit 25

 

100% Green

 

 

 

 

 

FC145

16 bits

Element Status 1

 

Bit 0

 

Level

 

 

 

 

 

Bit 1

 

Operated

 

 

 

 

 

Bit 2

 

Latched

 

 

 

 

 

Bit 3

 

Spare

 

 

 

 

 

FC147

16 bits

LED Intensity

 

0

 

Level 1

 

 

 

 

 

3

 

Level 2

 

 

 

 

 

6

 

Level 3

 

 

 

 

 

9

 

Level 4

 

 

 

 

 

12

 

Level 5

 

 

 

 

 

15

 

Level 6

 

 

 

 

 

FC150

32 bits

IP Address

 

 

 

 

42

MM300 MOTOR MANAGEMENT SYSTEM – COMMUNICATIONS GUIDE

Image 46
Contents MM300 Page Table of Contents MM300 Motor Management System Communications Guide MM300 Motor Management System Communications Guide Data Frame Format and Data Rate Electrical InterfaceData Packet Format Error Checking CRC-16 AlgorithmMM300 supported functions TimingFunction Code 03H Master Transmission Bytes Example Description Function Code 04HMaster/slave packet format for function code 03H Slave Response Bytes Example DescriptionMaster/slave packet format for function code 04H Function Code 05HMaster/slave packet format for function code 05H Data Function Code 06HMaster/slave packet format for function code 06H CRC CB B9Function code 7 bitmask Function Code 07HMaster/slave packet format for function code 07H Master/slave packet format for function code 08H Function Code 08HFunction Code 10H Diag CodeError Responses Master/slave packet format for function code 10HModbus memory map Actual ValuesREAL-TIME Clock General TimersTrip Counters Status Motor CONTACT/VIRTUAL INPUTS/OUTPUTS StatusSecurity Current MeteringPower Metering GCP Factory Test FLA RTD Maximium TemperatureMotor Starting Learned Data User MAP ValuesEvent Recorder Status BufferFlexlogic Setpoints CommandsCommunication Settings CommunicationREAL-TIME CLOCK/DAYLIGHT Savings Current SensingVoltage Sensing Motor Data SetupProcess Interlock RS485 Interface Modbus RTU Open Control Circuit Communication SetupUser MAP Addresses Reset Setup Mechanical JAMRTD OPEN/SHORT Circuit REQUIRED=IOG Thermistor CPUUndercurrent REQUIRED=IOA Underpower IOA + IOC or IOA + IOBGround Fault FLAPhase Reversal REQUIRED=IOB Phase Undervoltage REQUIRED=IOBPhase Overvoltage REQUIRED=IOB Load IncreaseStart Inhibit MaintenanceFlexlogic Timers Restart BlockCommunications Guide RS485 Interface Modbus RTU Communications Guide RS485 Interface Modbus RTU Contact Input Assignment Contact Outputs Auto / Manual ControlFlexlogic Equation Unsigned VALUE, 2 Decimal Places Unsigned ValueUnsigned VALUE, 1 Decimal Place Unsigned Long ValueMSB Unsigned Long VALUE, 3 Decimal PlacesDate MM/DD/YYYY LSBOn / YES OFF / noOFF USER2 USER1USER3 No Event/Trip To Date RS485 Interface Modbus RTU RS485 Interface Modbus RTU Not XOR Latch NOR Nand Timer Assign RS485 Interface Modbus RTU Definition RS485 Interface Modbus RTU TUE SUNMON WEDVbn Direct Bit FC180 FC181 FC182 FC183 RS485 Interface Modbus RTU Performing Commands Using Function Code 10H Master/slave packet format for performing commands Using the User Definable Memory MapCRC 7E CE RS485 Interface Modbus RTU Ethernet interface Profibus LED indications Profibus Output DataFieldbus interface external connections Profibus LEDProfibus Input Data Profibus DP-DiagnosticsSystem Standard Diagnostics Bytes 1 through F1BCommunications Guide Fieldbus Interface DeviceNet LED indications DeviceNet CommunicationsFieldbus interface external connections DeviceNet Class ObjectMessage Router Class Code 02H Identity Object Class Code 01HDeviceNet Object Class Code 03H DeviceNet Connection Object Class Code 05H Connection Object, Class Code 05h, ServicesAttribute Access Name Data Type Value Description Identity Object, Class Code 03h, Instance 01h, AttributesDeviceNet Motor Data Poll, Explicit Object Class Code A0H Motor Data Object, Class Code A0h, ServicesMotor Data Object, Class Code A0h, Attributes Item Description Size in Bytes Format Attribute Description Size in Bytes Explicit Motor Analog Data Object, Class Code B0h, Services0FH Data Formats, Explicit Motor Analog Data Object Attribute Item Description Size Format BytesFieldbus Interface Explicit Motor Control Object, Class Code B1h, Attributes Explicit Motor Control Object, Class Code B1h, ServicesDeviceNet Explicit Motor Object, Class Code B1H Data Value, Class B1hFieldbus Interface

MM300 specifications

The GE MM300 is a robust and versatile controller designed primarily for industrial automation applications. Built to tackle the demands of modern manufacturing environments, this controller offers a range of features that contribute to its popularity among engineers and operators.

One of the standout features of the GE MM300 is its scalability. The device can be easily configured to meet the needs of both small and large systems. Its modular architecture allows users to add or remove components based on the specific requirements of their applications, facilitating a more tailored approach to automation.

The MM300 supports various communication protocols, including Ethernet/IP, Modbus TCP, and more, ensuring seamless integration with a variety of devices and systems. This feature significantly enhances interoperability, allowing users to connect the controller to existing infrastructure without extensive reconfiguration.

In terms of processing power, the MM300 is equipped with a high-performance processor that can handle complex tasks with ease. With advanced data handling capabilities, it supports real-time data processing, enabling faster decision-making and improving overall operational efficiency. This capability is particularly beneficial for applications requiring precise control and monitoring.

Moreover, the GE MM300 boasts a user-friendly interface, featuring an intuitive programming environment that simplifies the development of control applications. This includes an integrated development environment (IDE) and support for popular programming languages, making it accessible for both seasoned programmers and those new to automation technologies.

The device is designed to operate in challenging industrial conditions, featuring a rugged construction that ensures durability and longevity. Its ability to withstand extreme temperatures, vibrations, and other environmental stressors enhances its reliability in demanding applications, which is crucial for minimizing downtime in production processes.

Security is another critical aspect of the GE MM300. The controller incorporates advanced security features to protect against unauthorized access and cyber threats, helping organizations ensure the integrity of their operations.

In summary, the GE MM300 stands out due to its scalability, versatile communication options, high processing capabilities, user-friendly programming environment, rugged design, and security features. These characteristics make it a reliable choice for industries seeking to enhance their automation processes and improve overall efficiency. Whether for small-scale or large-scale applications, the MM300 provides a comprehensive solution to meet the evolving needs of modern manufacturing.