Oneida Air Systems 2000 IX. Filter Maintenance, External Filter Cartridge Cleaning Intervals

Page 11

IX. Filter Maintenance

External Filter Cartridge Cleaning Intervals

When unit is turned off, use compressed air to blow dust off from exterior of filter. Hold nozzle at least 8” away from filter pleats*. Do not remove bottom dust pan before or during the blow-off process! Let dust settle into dust pan. Unclip and dump out dust. Filter removal is not required.

*WARNING: A close, direct blast with the compressed air nozzle too close to filter, may damage filter media. Always wear safety glasses while blowing off filter.

Caution: Fine dust collected in filter is hazardous to your health! Do not breathe!

Fan / Blower & Cyclone Outside Placement

Fan / Blower has a TEFC - Totally Enclosed Fan Cooled motor. Note: Use steel drum when placed outside.

Shown with optional Angle Iron Stand and 55 gal. steel drum.

Before Operation:

Check set screw and key in fan wheel, make sure fan wheel is secure. Fan blower should not vibrate. Fan wheel is dynamic, two-plane balanced to ISO 4.0 specifications.

Mount system and connect cyclone and dust bin. Make sure dust bin is in place before turning on the dust collector.

Do not operate Fan / Blower unless Cyclone and Dust Bin are in place! Motor will overheat!

Electrical Wiring:

Make sure power source matches wire voltage configurations on motor.

Prior to connecting to the power line, check motor plate for proper voltage and rotation connection. Wire for counter-clockwise rotation. Fan wheel must rotate counter-clockwise if looking down on fan housing.

Note: If fan is wired incorrectly and fan is rotating backwards, poor suction and airflow will result. See Wire Diagrams on motor plate.

Use 12 gauge cord for the fan / blowers.

Lubrication:

The motor is supplied with pre-lubricated ball bearings, lubricated for the life of the bearing.

Caution: Rotating Fan Blades! Keep objects clear of outlet.

10

Pro 2000 Owner’s Manual c O.A.S. 2007

Image 11
Contents Baldor Dust CollectorTable of Contents System Start-Up Information External Cartridge Filter Silencer Included with Filter II. Pro Series 2000 ConfigurationsIII. General Specifications & Fan Performance Curves For Minimum Mounting Heights w/ 62 Filter IV. DimensionsXXK200001 1 phase XXK200003 3 phase General AssemblyTOP VII. Bracket Assembly External 62 Filter Assembly VIII. Filter AssemblyExternal Filter Cartridge Cleaning Intervals IX. Filter MaintenanceMounting Instructions Filter Efficiency Gauge Mounting InstructionsExternal Filter can be cleaned using the following methods XI. Directions for Cleaning External FilterFollow Wiring Diagram on Motor XII. Wiring Instructions for Magnetic StarterXIII. Troubleshooting Oneida Collectors are designed for Wood Dust only XIV. Fire Hazards Read Before Installing and OperatingDelivery Risk of Loss Limited WarrantyXV. Terms and Conditions Checking in OrderXVI. Stand Assembly STG023055 Dust Containers XVII. AccessoriesReplacement Filter Bolt Together Angle Iron StandService Conditions Lubrication Interval Multiplier XVIII. Fan Motor MaintenanceSquare D Telemecanique Mag Starters XVIV. Remote Wiring Diagram