Oneida Air Systems 2000 manual XVIV. Remote Wiring Diagram, Square D Telemecanique Mag Starters

Page 21

XVIV. Remote Wiring Diagram

Retrofit (Wiring) of Wireless Remote into 220V Control Circuit of Square D / Telemecanique Mag Starters

Square D

Telemecanique

Mag Starters

AMK Series

Plug into 9 pin female Molex on back panel of starter base.

Important! Remove this factory installed Jumper Wire.

3

4

1

2

Start Stop

Remote

‘Black Box’

AMR220000

 

‘1A’

 

 

 

 

 

‘3’

 

 

 

 

 

‘2’

 

 

 

 

 

BRN YEL

YEL

 

 

 

3 Wire

 

 

 

 

 

 

 

 

 

Adaptor

YEL

 

 

 

 

Molex

 

 

 

 

AMA000000

RED

 

 

 

 

Female molex

 

A1

 

 

A2

at bottom of

 

 

 

 

 

 

 

 

starter

RED

1L1

3L2

5L3

13NO

Start / Stop

BRN

 

 

 

 

Push Button

YEL

Contactor

Assembly on

Starter (Molex)

RED

 

 

 

 

 

RED

 

 

 

 

 

 

2T1

4T2

6T3

 

YEL

 

 

 

Amp

 

 

 

 

Adjustment

BRN

 

 

 

Dial

 

 

 

 

 

 

BRN

 

 

Overload

 

YEL

 

 

 

 

98

97

95

96

RED

 

RED

 

 

 

 

 

 

 

 

 

 

BRN

Wire

Nuts

BRN

Retrofit (Wiring) of Wireless Remote into 220V OAS Import Magnetic Starters: AMI020000 AMI030000

NHD, Inc.

Mag Starters

Remote is mounted inside starter top cover by using double-sided tape (supplied).

YEL

BRN

Remote BRN

‘Black Box’ YEL

RED

YEL

BRN

BRN

YEL

RED

RED

A1

 

 

A2

1L1

3L2

5L3

13NO

Contactor

17

 

 

 

 

18

2T1

4T2

6T3

14NO

RED

Red

Remote Controller Diagram

 

 

 

Red

Red:

 

 

Yellow

AC Power

Blue

Red

Yellow:

(ON) (OFF)

Yellow

N/O contact (ON)

 

Black

Brown

Brown:

 

 

(antenna)

Brown

N/C contact (OFF)

 

 

 

 

 

20

 

 

 

 

 

 

 

Red

Amp

Overload

 

Adjustment

 

 

 

 

Dial

 

 

 

BRN

98

97

96

95

2T1

4T2

6T3

 

Remove this

 

 

 

 

 

 

 

 

factory installed

 

 

 

 

red wire!

Pro 2000 Owner’s Manual c O.A.S. 2007

Image 21
Contents Baldor Dust CollectorTable of Contents System Start-Up Information External Cartridge Filter Silencer Included with Filter II. Pro Series 2000 ConfigurationsIII. General Specifications & Fan Performance Curves For Minimum Mounting Heights w/ 62 Filter IV. DimensionsXXK200001 1 phase XXK200003 3 phase General AssemblyTOP VII. Bracket Assembly External 62 Filter Assembly VIII. Filter AssemblyExternal Filter Cartridge Cleaning Intervals IX. Filter MaintenanceMounting Instructions Filter Efficiency Gauge Mounting InstructionsExternal Filter can be cleaned using the following methods XI. Directions for Cleaning External FilterFollow Wiring Diagram on Motor XII. Wiring Instructions for Magnetic StarterXIII. Troubleshooting Oneida Collectors are designed for Wood Dust only XIV. Fire Hazards Read Before Installing and OperatingXV. Terms and Conditions Limited WarrantyChecking in Order Delivery Risk of Loss XVI. Stand Assembly STG023055 Replacement Filter XVII. AccessoriesBolt Together Angle Iron Stand Dust ContainersService Conditions Lubrication Interval Multiplier XVIII. Fan Motor MaintenanceSquare D Telemecanique Mag Starters XVIV. Remote Wiring Diagram