Oneida Air Systems 2000 manual Filter Efficiency Gauge Mounting Instructions

Page 12

X. Filter Efficiency Gauge Mounting Instructions

Elbow Plenum

(Side View)

Air Flow to Filter

0

1

2

3

4

 

 

 

 

 

 

5

INCHES W.C.

Mounting Instructions

1.Mount brass static pressure tube in plenum with tip pointed into the air stream.

Use mounting bracket and sheet metal screws if interior of plenum is not accessible. Refer to drawings for location of brass static pressure tube.

2.Refer to instructions provided with gauge for mounting to bracket.

3.Mount gauge up to 8’ away, mounting it closer will not affect reading.

4.Connect clear tubing from brass static pressure tube to the port labeled “high” on the back of the Pressure gauge.

5.Make sure the tubing is not crushed or kinked along its entire length, cut shorter if necessary.

Gauge Reading Instructions

1.Gauge may need to be zeroed. Follow the instructions provided with pressure gauge.

2.Take the initial reading with cleaned filter(s) and the typical number of blast gates open in normal operation.

3.Always read the gauge with the same number of gates open. The more gates open, the higher the pressure reading on the gauge.

4.When the gauge rises to 3”, it’s time to clean your filter.

After many cleaning cycles, a filter’s pressure will rise after each cleaning. An older filter does not get as clean as a new filter.

11

Pro 2000 Owner’s Manual c O.A.S. 2007

Image 12
Contents Dust Collector BaldorTable of Contents System Start-Up Information II. Pro Series 2000 Configurations External Cartridge Filter Silencer Included with FilterIII. General Specifications & Fan Performance Curves IV. Dimensions For Minimum Mounting Heights w/ 62 FilterGeneral Assembly XXK200001 1 phase XXK200003 3 phaseTOP VII. Bracket Assembly VIII. Filter Assembly External 62 Filter AssemblyIX. Filter Maintenance External Filter Cartridge Cleaning IntervalsFilter Efficiency Gauge Mounting Instructions Mounting InstructionsXI. Directions for Cleaning External Filter External Filter can be cleaned using the following methodsXII. Wiring Instructions for Magnetic Starter Follow Wiring Diagram on MotorXIII. Troubleshooting XIV. Fire Hazards Read Before Installing and Operating Oneida Collectors are designed for Wood Dust onlyLimited Warranty XV. Terms and ConditionsChecking in Order Delivery Risk of LossXVI. Stand Assembly STG023055 XVII. Accessories Replacement FilterBolt Together Angle Iron Stand Dust ContainersXVIII. Fan Motor Maintenance Service Conditions Lubrication Interval MultiplierXVIV. Remote Wiring Diagram Square D Telemecanique Mag Starters