Oneida Air Systems 2000 manual III. General Specifications & Fan Performance Curves

Page 5

III. General Specifications & Fan Performance Curves

1973 CFM @ 2” SP w/c w/o filter

Full 16 gauge galvanized cyclone & 14 ga. barrel

Rectangular inlet with included Square to Round to 8”

Rectangular outlet

Cast aluminum fan wheel

back inclined non-sparking, non-ferrous dynamic, two-planed balanced to ISO 6.3 specifications.

Sound 80 - 82dB @ 10’ with Built-in Silencer and Filter

130 Sq. Ft. Filter Media / Spun-Bonded

U.S. Made Baldor / TEFC / Class F / 1.15 SF

Single Phase

Three Phase

5hp Motor

5hp Motor

208 - 230V

208 - 230 / 460V

19.8A

13.6 - 12.4 / 6.2A

System Fan Curve

Pro Series 2000

Static pressure and volume together determine a fan’s performance. Several factors, such as layout of ductwork and diameter of openings, can affect a fan’s performance.

Static Pressure at Cyclone Inlet

12

 

 

 

 

 

12

 

10

 

 

 

 

 

10

 

 

11.1

 

 

 

 

 

 

CFM

SP @

8.1

 

8

w/o Filter

Inlet

 

 

1973

2.00

 

 

 

 

5.8

6

1802

2.75

 

 

 

 

1709

4.00

 

4

 

1543

5.80

 

4

 

 

1273

8.10

 

2.75

 

 

 

987

10.00

- With Filter

2

2

736

11.10

- Without Filter

 

 

0

12.00

*Fan curves vary slightly with different filter packages.

 

0

 

 

 

 

 

 

 

0 200 400 600 800 1000 1200 1400 1600 1800 2000

CFM

4

 

Pro 2000 Owner’s Manual c O.A.S. 2007

Image 5
Contents Baldor Dust CollectorTable of Contents System Start-Up Information External Cartridge Filter Silencer Included with Filter II. Pro Series 2000 ConfigurationsIII. General Specifications & Fan Performance Curves For Minimum Mounting Heights w/ 62 Filter IV. DimensionsXXK200001 1 phase XXK200003 3 phase General AssemblyTOP VII. Bracket Assembly External 62 Filter Assembly VIII. Filter AssemblyExternal Filter Cartridge Cleaning Intervals IX. Filter MaintenanceMounting Instructions Filter Efficiency Gauge Mounting InstructionsExternal Filter can be cleaned using the following methods XI. Directions for Cleaning External FilterFollow Wiring Diagram on Motor XII. Wiring Instructions for Magnetic StarterXIII. Troubleshooting Oneida Collectors are designed for Wood Dust only XIV. Fire Hazards Read Before Installing and OperatingXV. Terms and Conditions Limited WarrantyChecking in Order Delivery Risk of LossXVI. Stand Assembly STG023055 Replacement Filter XVII. AccessoriesBolt Together Angle Iron Stand Dust ContainersService Conditions Lubrication Interval Multiplier XVIII. Fan Motor MaintenanceSquare D Telemecanique Mag Starters XVIV. Remote Wiring Diagram