SECTION 2: CIRCUIT REQUIREMENTS
G1028Z Wiring | G1029 Wiring |
The G1028Z Dust Collector is
A plug is not provided with the G1028Z. It will be necessary to purchase a standard 110V plug from your local hardware store. If you are rewiring for 220V, see Figure 1 for the recommended 220V receptacle.
Circuit Breaker: The 11⁄2 H.P. motor will draw roughly 18 amps at 110V or 9 amps at 220V. We recommend a using 20 amp circuit breaker for 110V or 220V operation. Circuit breakers rated higher will not adequately protect the circuit. If you are using a fuse, we recommend a 30 amp slow blow for 110V or 220V operation. Fuses rated higher will not adequately protect the circuit.
The G1029 Dust Collector is
A plug is not provided with the G1029. Refer to Figure 1 for recommended 220V receptacle.
Circuit Breaker: The 2 H.P. motor will draw roughly 12 amps @ 220V. We recommend using a 20 amp circuit breaker. Circuit breakers rated higher will not adequately protect the motor. If you are using a fuse, we recommend 30 amp slow blow 220V service. Fuses rated higher will not adequately protect the motor.
Figure 1. Recommended 220V receptacle.
G1028Z/G1029 Dust Collector |