ATTACH INLET

Refer to Figure 7.

inlet needs to be attached to right side of dust collector assembly. To attach inlet:

Position inlet over 2W' hole on right side of dust collector assembly.

Secure inlet using four 4.2-1.4 x 12ram thread-forming screws.

Figure 7 - Attaching Inlet

ATTACH HOSE

Refer to Figure 8.

Hose needs to be attached to the inlet using hose clamp. To attach hose:

Slide hose clamp onto one end of hose. Loosen clamp screw if required to slide hose clamp onto hose.

Position the hose clamp wires on the hose grooves.

Slide hose with clamp onto inlet.

Tighten hose clamp screw to secure hose with inlet.

Slide other hose clamp onto the opposite hose end. This end will be connected to the dust producing machine

Figure 8 - Attaching Hose

DANGER: Do not permit fingers to touch terminals of plug when installing or removing the plug to or from the outlet. WARNING: Do not connect to power source until unit is completely assembled.

POWER SOURCE

Motor is designed for operation on the voltage and fre- quency specified on motor nameplate.

Normal loads will be handled safely on voltages not more than 10% above or below the specified voltage.

Running unit on voltages not within range may cause over- heating and motor burnout.

GROUNDING INSTRUCTIONS

Refer to Figure 9.

This tool is equipped with a 3-conductor cord.

Do not remove or alter grounding prong in any manner. In the event of malfunction or breakdown, grounding provides path of least resistance for electrical current to reduce risk of electrical shock.

Plug must be plugged into a matching outlet that is proper- ly installed and grounded in accordance with all local codes and ordinances.

The conductor with insulation having an outer surface which is green is equipment grounding conductor. If repair

or replacement is necessary, make sure equipment grounding conductor is not connected to line terminal.

If power cord is worn, cut or damaged in any way, have it replaced immediately.

Properly Grounded Outlet

Grounding Prong

3-Prong Plug @I__

Figure 9 - 3-Prong Receptacle

CAUTION: improper connection of the equipment-groundingconductor can result in a risk of electrical shock.

EXTENSION CORDS

The use of any extension cord will cause some drop in the voltage and loss of power.

Wires of the extension cord must be sufficient in size to carry the current and maintain adequate voltage.

Use the table below to determine the minimum wire size (A.W.G.) extension cord.

Use only 3-wire extension cords having 3-prong grounding

type plugs and 3-pole receptacles which accept the tool plug.

If extension cord is worn, cut or damaged in any way, have it replaced immediately.

Extension

Cord Length

Wire

Size

A.W.G.

Up to

50 ft

16

Note:

Using

extension cords over 50 ft. long is not

recommended.

 

Image 5
Contents Operators Manual MY-HOME to Arrange for Free Repair Know HOW to USE ToolTool should be Maintained Be Prepared for JOBTools Needed Cut-awayviewof Attach Inlet Power SourceAttach Hose Grounding InstructionsDescription Corrective Action Symptom PossibleReplacement Parts Illustration for Dust Collector Description QTYEL Operador Debe Estar Preparado Para EL Trabajo Herramienta CraftsmanPrepare EL Area DE Trabajo Para LA Tarea Realizar SE Debe DAR Mantenimiento a LA HerramientaSeleccione UN Lugar Para Instalar EL Colector DE Polvo Herramientas NecesariasInstale LOS Soportes Para LA Pared EN Instale Anclas Para ParedInstale LA Bolsa DEL Colector Monte EL CON Junto DEL Colector DE Polvo EN LA ParedInstale EL Collar Cordones DE Extension Instale LA EntradaInstale LA Manguera Especificaciones DescripcionColector DE Polvo Como Vaciar LA Bolsa DEL ColectorCausass Posibles Medida Correctiva SintomaOur Home