Grizzly T26416 owner manual Troubleshooting, Symptom Possible Cause Solution

Page 16

Troubleshooting

Symptom

Possible Cause

Solution

 

 

 

 

 

 

 

Air leaking at trig-

1.

O-rings in trigger valve housing

1.

O-rings must be replaced

ger valve area.

 

are damaged.

 

& operation of safety probe

 

 

 

 

must be checked.

 

 

 

 

 

 

 

Air leaking

1.

Loose screws in housing.

1.

Tighten screws.

 

between housing

2.

Damaged O-ring.

2.

Replace O-ring.

 

and hose.

3.

Loose air fitting.

3.

Tighten air fitting & use tef-

 

 

 

 

lon tape.

 

 

 

 

 

 

 

Air leaking

1.

Damaged seal.

1.

Replace damaged seals.

between housing

 

 

 

 

 

 

and cap assembly.

 

 

 

 

 

 

 

 

 

 

 

Tool skips staples

1.

Air leaks.

1.

Tighten screws and fittings.

while discharging.

2.

Dirt in nose.

2.

Clean nose.

 

 

3.

Dirt or damage prevents sta-

3.

Clean

magazine

and

 

 

ples from moving freely in mag-

 

inspect/repair damage.

 

 

azine.

 

 

 

 

 

4.

Inadequate air flow to tool.

4.

Check fitting, hose, com-

 

 

 

 

pressor & air pressure.

 

5.

Worn O-ring on piston or lack

5. replace

piston

O-ring.

 

 

of lubrication.

 

Lubricate.

 

 

 

6. damaged O-rings on trigger

6. replace

trigger

valve

 

 

valve.

 

O-rings.

 

 

 

7.

Cap seal leaking.

7.

Replace cap seal.

 

 

 

 

 

 

 

Tool runs slowly

1.

Stapler is not sufficiently lubri-

1.

Lubricate stapler.

 

or has a loss of

 

cated.

 

 

 

 

power.

2.

Broken spring in cap assem-

2.

Replace spring.

 

 

 

bly.

 

 

 

 

 

3.

Exhaust port in cap is blocked.

3.

Clean or replace damaged

 

 

 

 

internal parts.

 

 

 

 

 

 

Fasteners frequent-

1. Staples are the wrong size.

1.

Use correct staples.

 

ly jam the stapler.

2.

Staples are bent or dirty.

2.

Use undamaged, clean sta-

 

 

 

 

ples.

 

 

 

3.

Magazine or nose screws are

3.

Tighten magazine.

 

 

 

loose.

 

 

 

 

 

4.

Driver or driver guide are worn

4.

Replace worn or damaged

 

 

or damaged.

 

parts.

 

 

 

 

 

 

 

 

 

-14-

Model T26416 Crown Stapler

Image 16
Contents Model T26416 Page Table of Contents Safety Safety Instructions For Pneumatic ToolsBefore Operating This Equipment Mation about proper operation of the equipmentSafety Instructions for Pneumatic Tools Additional Safety for Staplers Introduction SpecificationsForeword Contact Info SET UP UnpackingInventoryAir Deflection Loading StaplesTo load the stapler Compressed Air System Test Run To test run staplerOperations To perform a typical operationAccessories Safety glassesMaintenance CleaningLubricatingTo replace piston assembly ServiceReplacing O-Rings Piston Assemblies Troubleshooting Symptom Possible Cause SolutionParts To reduce risk of injuryParts List DescriptionWArranty