DETAILED COOLING CAPACITIES (CONT.)

EVAPORATOR AIR

 

 

 

 

 

 

 

CONDENSER ENTERING AIR TEMPERATURES deg ˚F (˚C)

 

 

 

 

 

 

 

 

 

75 (23.9)

 

 

85 (29.4)

 

 

95 (35)

 

 

105 (40.6)

 

 

115 (46.1)

 

 

125 (51.7)

 

CFM

EWB

Capacity MBtuh

Total

Capacity MBtuh

Total

Capacity MBtuh

Total

Capacity MBtuh

Total

Capacity MBtuh

Total

Capacity MBtuh

Total

 

 

System

 

 

System

 

 

 

System

 

 

System

 

 

System

 

 

System

 

 

Total

Sens

KW

Total

Sens

KW

Total

 

Sens

KW

Total

Sens

KW

Total

Sens

KW

Total

Sens

KW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25HCR348C30 Outdoor Section

With FC4DN(F,B)048 Indoor Section

 

 

 

 

 

 

 

 

72

56.21

28.99

3.38

54.21

28.21

3.75

52.11

 

27.40

4.17

49.91

26.56

4.64

47.60

25.69

5.14

45.17

24.78

5.69

 

67

50.95

35.73

3.35

49.09

34.93

3.72

47.13

 

34.09

4.14

45.09

33.23

4.60

42.95

32.33

5.10

40.70

31.39

5.64

1400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

47.21

34.48

3.32

45.45

33.67

3.70

43.61

 

32.83

4.11

41.68

31.95

4.57

39.65

31.04

5.06

37.52

30.09

5.59

 

62

46.37

42.45

3.32

44.67

41.60

3.69

42.90

 

40.70

4.11

41.06

39.73

4.56

39.16

38.67

5.06

37.28

37.28

5.59

 

57

44.92

44.92

3.31

43.55

43.55

3.69

42.11

 

42.11

4.10

40.59

40.59

4.56

38.98

38.98

5.06

37.28

37.28

5.59

 

72

57.34

30.38

3.44

55.26

29.59

3.82

53.08

 

28.77

4.24

50.79

27.92

4.70

48.39

27.04

5.21

45.88

26.12

5.76

 

67

51.97

37.99

3.41

50.03

37.17

3.78

48.00

 

36.32

4.20

45.88

35.44

4.66

43.66

34.52

5.16

41.34

33.56

5.70

1600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

48.15

36.59

3.38

46.33

35.77

3.76

44.42

 

34.91

4.17

42.42

34.01

4.63

40.32

33.08

5.12

38.13

32.11

5.66

 

62

47.44

45.41

3.38

45.72

44.48

3.76

43.94

 

43.45

4.17

42.15

42.15

4.63

40.45

40.45

5.13

38.66

38.66

5.67

 

57

46.73

46.73

3.38

45.28

45.28

3.75

43.76

 

43.76

4.17

42.15

42.15

4.63

40.46

40.46

5.13

38.67

38.67

5.67

 

72

58.21

31.70

3.50

56.06

30.90

3.88

53.81

 

30.07

4.30

51.45

29.21

4.76

48.99

28.32

5.27

46.41

27.39

5.82

 

67

52.75

40.15

3.47

50.75

39.31

3.84

48.66

 

38.45

4.26

46.48

37.55

4.72

44.21

36.61

5.22

41.83

35.62

5.77

1800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

48.88

38.60

3.44

47.00

37.76

3.82

45.04

 

36.88

4.23

42.99

35.97

4.69

40.84

35.01

5.19

38.60

34.01

5.72

 

62

48.48

47.87

3.44

46.75

46.75

3.82

45.14

 

45.14

4.24

43.46

43.46

4.70

41.69

41.69

5.20

39.82

39.82

5.74

 

57

48.26

48.26

3.44

46.74

46.74

3.82

45.14

 

45.14

4.24

43.46

43.46

4.70

41.69

41.69

5.20

39.82

39.82

5.74

 

Cooling Indoor

Capa-

Power

Furnace Model

 

Model

city

 

 

 

 

*FC4DN(F,B)048

1.00

1.00

 

 

CSRH*6012A**

0.98

0.98

 

 

FK4DNB006

1.01

0.95

 

 

FK4DNF005

0.99

0.95

 

 

CAR**4817A**

0.94

0.92

58CV(A,X)090--- 16

22

CNRH*4821A**

0.96

0.94

58CV(A,X)090--- 16

CNRH*6024A**

0.98

0.94

58CV(A,X)090--- 16

 

 

CSRH*4812A**

0.96

0.94

58CV(A,X)090--- 16

 

CSRH*6012A**

0.98

0.94

58CV(A,X)090--- 16

 

CAR**4821A**

0.96

0.94

58CV(A,X)110--- 20

 

CAR**6021A**

0.99

0.95

58CV(A,X)110--- 20

 

CNRH*4821A**

0.97

0.95

58CV(A,X)110--- 20

 

CNRH*6024A**

0.99

0.95

58CV(A,X)110--- 20

 

CNRV*4821A**

0.96

0.94

58CV(A,X)110--- 20

 

CSRH*4812A**

0.96

0.94

58CV(A,X)110--- 20

 

CSRH*6012A**

0.98

0.94

58CV(A,X)110--- 20

 

CAR**4824A**

0.97

0.93

58CV(A,X)135--- 22

 

CAR**6024A**

0.99

0.95

58CV(A,X)135--- 22

 

CNRH*4821A**

0.97

0.93

58CV(A,X)135--- 22

 

CNRH*6024A**

0.99

0.95

58CV(A,X)135--- 22

 

CNRV*4824A**

0.97

0.93

58CV(A,X)135--- 22

 

CNRV*6024A**

0.99

0.95

58CV(A,X)135--- 22

 

CSRH*4812A**

0.97

0.93

58CV(A,X)135--- 22

 

CSRH*6012A**

0.99

0.95

58CV(A,X)135--- 22

 

CAR**4824A**

0.97

0.93

58CV(A,X)155--- 22

 

CAR**6024A**

0.99

0.93

58CV(A,X)155--- 22

 

CNRH*4821A**

0.97

0.93

58CV(A,X)155--- 22

 

CNRH*6024A**

0.99

0.95

58CV(A,X)155--- 22

 

CNRV*4824A**

0.97

0.93

58CV(A,X)155--- 22

 

CNRV*6024A**

0.99

0.95

58CV(A,X)155--- 22

 

CSRH*4812A**

0.97

0.93

58CV(A,X)155--- 22

 

CSRH*6012A**

0.99

0.93

58CV(A,X)155--- 22

 

CAR**4821A**

0.96

0.96

58MVB080--- 20

 

CAR**6021A**

0.98

0.96

58MVB080--- 20

Cooling Indoor

Capa-

Power

Furnace Model

Model

city

 

 

CNRH*4821A**

0.96

0.96

58MVB080--- 20

CNRH*6024A**

0.98

0.96

58MVB080--- 20

CNRV*4821A**

0.96

0.96

58MVB080--- 20

CSRH*4812A**

0.96

0.96

58MVB080--- 20

CSRH*6012A**

0.98

0.94

58MVB080--- 20

CAR**4821A**

0.96

0.96

58MVB100--- 20

CAR**6021A**

0.99

0.95

58MVB100--- 20

CNRH*4821A**

0.96

0.94

58MVB100--- 20

CNRH*6024A**

0.98

0.94

58MVB100--- 20

CNRV*4821A**

0.96

0.94

58MVB100--- 20

CSRH*4812A**

0.96

0.94

58MVB100--- 20

CSRH*6012A**

0.98

0.94

58MVB100--- 20

CAR**4824A**

0.96

0.94

58MVB120--- 20

CAR**6024A**

0.98

0.94

58MVB120--- 20

CNRH*4821A**

0.96

0.94

58MVB120--- 20

CNRH*6024A**

0.98

0.94

58MVB120--- 20

CNRV*4824A**

0.96

0.94

58MVB120--- 20

CNRV*6024A**

0.98

0.94

58MVB120--- 20

CSRH*4812A**

0.96

0.94

58MVB120--- 20

CSRH*6012A**

0.98

0.94

58MVB120--- 20

CAR**4821A**

0.96

0.96

58UVB080--- 20

CAR**6021A**

0.98

0.96

58UVB080--- 20

CNRV*4821A**

0.96

0.96

58UVB080--- 20

CAR**4821A**

0.96

0.96

58UVB100--- 20

CAR**6021A**

0.99

0.95

58UVB100--- 20

CNRV*4821A**

0.96

0.94

58UVB100--- 20

CAR**4824A**

0.96

0.94

58UVB120--- 20

CAR**6024A**

0.98

0.94

58UVB120--- 20

CNRV*4824A**

0.96

0.94

58UVB120--- 20

CNRV*6024A**

0.98

0.94

58UVB120--- 20

See notes on page 23

Image 22
Contents Industry Leading Features / Benefits 25HCR3CStandard Features Model Number NomenclaturePhysical Data Unit SIZE---SERIES, VoltageAccessory Thermostats AccessoriesAccessory Usage Guideline MotorMasterr Low-Ambient Controller Electrical Data Charging Subcooling TXV-TYPE Expansion DeviceDimensions Heat LOSS, Unit Integrated Heating CAPACITY, Mbtuh Building 25HCR3C Balance Point WorksheetCombination Ratings 30---30 Indoor Model Capa Voltage Factory StandardTDR&TXV CAR**3614A 28,600 FK4DNF003 FK4DNB006 36---3042---30 FK4DNF005 48---3060---30 Detailed Cooling Capacities 25HCR318C Outdoor Section With FA4CNF,C018 Indoor Section700 Capacity MBtuh Total System Sens25HCR324C Outdoor Section With FA4CNF,C024 Indoor Section 800875 Capacity Power Furnace Model25HCR330C Outdoor Section With FC4DNF030 Indoor Section 10001050 Cooling Indoor Model Capacity Power Furnace Model25HCR336C30 Outdoor Section With FC4DNF,B036 Indoor Section 12001400 25HCR342C Outdoor Section With FC4DNF,B042 Indoor Section1225 15751600 Cooling Indoor Capa Power Furnace Model City25HCR348C30 Outdoor Section With FC4DNF,B048 Indoor Section 18001750 Capacity MBtuh Total Sys System25HCR360C30 Outdoor Section With FC4DNF,B060 Indoor Section 200025HCR318C Outdoor Section With FA4CNF,C018 Indoor Section Heat Pump Heating PerformanceFC4DNF018 FC4DNF024 FF1ENE018 FF1ENE024 FK4DNF001 FK4DNF002 FC4DNF030 25HCR324C Outdoor Section With FA4CNF,C024 Indoor SectionFF1ENE030 25HCR330C Outdoor Section With FC4DNF030 Indoor Section FK4DNF001 FK4DNF00225HCR336C30 Outdoor Section With FC4DNF,B036 Indoor Section FK4DNF002 FK4DNF00325HCR342C Outdoor Section With FC4DNF,B042 Indoor Section FK4DNB00625HCR348C30 Outdoor Section With FC4DNF,B048 Indoor Section FK4DNB006 FK4DNF00525HCR360C30 Outdoor Section With FC4DNF,B060 Indoor Section Guide Specifications General ProductsCatalog No 25HCR3C---2PD