HEAT PUMP HEATING PERFORMANCE (CONT.)
INDOOR AIR |
|
|
|
|
|
|
|
|
|
|
| OUTDOOR COIL ENTERING AIR TEMPERATURES ˚F (˚C) |
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
| 7 |
|
| 17 |
|
|
| 27 |
|
| 37 (2.8) |
|
|
| 47 (8.3) |
|
| 57 (13.9) |
|
| 67 (19.4) |
| ||
|
| Capacity MBtuh | Total | Capacity MBtuh | Total | Capacity MBtuh |
| Total | Capacity MBtuh | Total | Capacity MBtuh |
| Total | Capacity MBtuh | Total | Capacity MBtuh | Total | Capacity MBtuh | Total | |||||||||
EDB | CFM | Sys- | Sys- |
| Sys- | Sys- |
| Sys- | Sys- | Sys- | Sys- | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
| tem |
|
| tem |
|
|
| tem |
|
| tem |
|
|
| tem |
|
| tem |
|
| tem |
|
| tem | ||
|
| Total |
| Integ* | Total | Integ* | Total | Integ* |
| Total | Integ* | Total | Integ* |
| Total | Integ* | Total | Integ* | Total | Integ* | ||||||||
|
|
| KW† | KW† |
| KW† | KW† |
| KW† | KW† | KW† | KW† | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 25HCR324C Outdoor Section With FA4CN(F,C)024 Indoor Section |
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 700 | 9.44 |
| 8.68 | 1.55 | 11.81 | 10.85 | 1.61 | 14.36 | 13.10 |
| 1.68 | 17.25 | 15.32 | 1.76 | 20.46 | 18.61 |
| 1.86 | 23.99 | 23.99 | 1.98 | 27.61 | 27.61 | 2.10 | 31.25 | 31.25 | 2.23 |
65 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
800 | 9.61 |
| 8.85 | 1.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 0.00 | 0.00 | 0.00 | 0.00 | 20.73 | 18.87 |
| 1.84 | 24.32 | 24.32 | 1.96 | 27.53 | 27.53 | 2.04 | 30.88 | 30.88 | 2.16 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 900 | 9.78 |
| 9.00 | 1.59 | 12.17 | 11.18 | 1.64 | 14.77 | 13.47 |
| 1.69 | 17.71 | 15.73 | 1.76 | 20.97 | 19.08 |
| 1.84 | 24.46 | 24.46 | 1.93 | 27.30 | 27.30 | 2.02 | 30.39 | 30.39 | 2.12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 700 | 9.17 |
| 8.43 | 1.61 | 11.57 | 10.63 | 1.69 | 14.13 | 12.89 |
| 1.76 | 16.99 | 15.09 | 1.84 | 20.17 | 18.36 |
| 1.95 | 23.67 | 23.67 | 2.08 | 27.42 | 27.42 | 2.21 | 31.11 | 31.11 | 2.35 |
70 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
800 | 9.35 |
| 8.60 | 1.63 | 11.76 | 10.81 | 1.70 | 14.34 | 13.07 |
| 1.76 | 17.23 | 15.30 | 1.84 | 20.45 | 18.61 |
| 1.93 | 24.00 | 24.00 | 2.05 | 27.46 | 27.46 | 2.15 | 30.88 | 30.88 | 2.28 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 900 | 9.51 |
| 8.75 | 1.66 | 11.93 | 10.97 | 1.72 | 14.52 | 13.24 |
| 1.77 | 17.45 | 15.49 | 1.84 | 20.69 | 18.83 |
| 1.93 | 24.25 | 24.25 | 2.04 | 27.33 | 27.33 | 2.12 | 30.52 | 30.52 | 2.23 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 700 | 8.87 |
| 8.16 | 1.68 | 11.31 | 10.39 | 1.76 | 13.90 | 12.67 |
| 1.84 | 16.72 | 14.85 | 1.93 | 19.86 | 18.07 |
| 2.04 | 23.36 | 23.36 | 2.17 | 27.20 | 27.20 | 2.34 | 30.95 | 30.95 | 2.47 |
75 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
800 | 9.06 |
| 8.33 | 1.70 | 11.51 | 10.57 | 1.78 | 14.11 | 12.86 |
| 1.85 | 16.96 | 15.06 | 1.92 | 20.17 | 18.35 |
| 2.03 | 23.68 | 23.68 | 2.15 | 27.32 | 27.32 | 2.26 | 30.82 | 30.82 | 2.39 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 900 | 9.22 |
| 8.49 | 1.73 | 11.68 | 10.74 | 1.80 | 14.29 | 13.03 |
| 1.86 | 17.18 | 15.26 | 1.93 | 20.40 | 18.57 |
| 2.02 | 23.95 | 23.95 | 2.14 | 27.30 | 27.30 | 2.23 | 30.56 | 30.56 | 2.35 |
| Heating Indoor Model | Capacity | Power | Furnace Model |
| Heating Indoor Model | Capacity | Power | Furnace Model | ||
| *FA4CN(F,C)024 | 1.00 | 1.00 |
|
|
| CSRH*2412A** | 0.99 | 0.94 | 58CV(A,X)110 | |
|
|
|
|
|
|
|
|
|
|
|
|
| FA4CN(F,C)030 | 1.00 | 0.98 |
|
| CSRH*3012A** | 0.98 | 0.93 | 58CV(A,X)110 | ||
| FC4DNF024 | 1.00 | 0.95 |
|
|
| CNRH*2417A** | 0.99 | 0.94 | 58CV(A,X)135 | |
|
|
|
|
|
|
|
|
|
|
|
|
| FC4DNF030 | 1.00 | 0.93 |
|
| CNRH*3017A** | 0.98 | 0.93 | 58CV(A,X)135 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| FF1ENE024 | 1.00 | 1.00 |
|
| CSRH*2412A** | 0.99 | 0.94 | 58CV(A,X)135 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| FF1ENE030 | 1.00 | 1.00 |
|
| CSRH*3012A** | 0.98 | 0.93 | 58CV(A,X)135 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| FK4DN(B,F)003 | 0.98 | 0.91 |
|
| CNRH*2417A** | 0.99 | 0.93 | 58CV(A,X)155 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| FK4DNF001 | 0.99 | 0.95 |
|
| CNRH*3017A** | 0.98 | 0.93 | 58CV(A,X)155 | ||
| FK4DNF002 | 0.99 | 0.92 |
|
|
| CSRH*2412A** | 0.99 | 0.94 | 58CV(A,X)155 | |
|
|
|
|
|
|
|
|
|
|
|
|
| CAR**2414A** | 1.00 | 0.98 |
|
| CSRH*3012A** | 0.98 | 0.93 | 58CV(A,X)155 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| CAR**2417A** | 1.00 | 0.98 |
|
| CNRH*2417A** | 0.99 | 0.94 | 14 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| CAR**3014A** | 1.00 | 0.99 |
|
| CNRH*3017A** | 0.98 | 0.93 | 14 | ||
|
|
|
|
|
|
|
|
|
|
|
|
25 | CAR**3017A** | 1.00 | 0.99 |
|
| CSRH*2412A** | 1.00 | 0.95 | 14 | ||
|
|
|
|
|
|
|
|
|
|
| |
CNRF*2418A** | 1.00 | 0.96 |
|
|
| CSRH*3012A** | 0.98 | 0.93 | 14 | ||
|
|
|
| ||||||||
| CNRH*2417A** | 1.00 | 0.96 |
|
|
| CAR**2417A** | 0.99 | 0.95 | 14 | |
|
|
|
|
|
|
|
|
|
|
|
|
| CNRH*3017A** | 1.00 | 0.99 |
|
| CAR**3017A** | 0.98 | 0.94 | 14 | ||
| CNRV*2414A** | 1.00 | 0.96 |
|
|
| CNRH*2417A** | 0.99 | 0.94 | 14 | |
|
|
|
|
|
|
|
|
|
|
|
|
| CNRV*2417A** | 1.00 | 0.96 |
|
| CNRH*3017A** | 0.98 | 0.93 | 14 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| CNRV*3014A** | 1.00 | 0.99 |
|
| CNRV*2417A** | 0.99 | 0.94 | 14 | ||
| CNRV*3017A** | 1.00 | 0.99 |
|
|
| CNRV*3017A** | 0.98 | 0.93 | 14 | |
|
|
|
|
|
|
|
|
|
|
|
|
| CSRH*2412A** | 1.00 | 0.96 |
|
| CSRH*2412A** | 0.99 | 0.94 | 14 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| CSRH*3012A** | 1.00 | 0.99 |
|
| CSRH*3012A** | 0.98 | 0.93 | 14 | ||
| CAR**2414A** | 0.99 | 0.96 | 12 |
| CNRH*2417A** | 0.99 | 0.94 | 14 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| CAR**3014A** | 0.98 | 0.94 | 12 | CNRH*3017A** | 0.98 | 0.93 | 14 | |||
|
|
|
|
|
|
|
|
|
|
|
|
| CNRH*2417A** | 0.99 | 0.94 | 12 | CSRH*2412A** | 0.99 | 0.94 | 14 | |||
|
|
|
|
|
|
|
|
|
|
|
|
| CNRH*3017A** | 0.98 | 0.94 | 12 | CSRH*3012A** | 0.98 | 0.93 | 14 | |||
|
|
|
|
|
|
|
|
|
|
|
|
| CNRV*2414A** | 0.99 | 0.94 | 12 | CNRH*2417A** | 0.99 | 0.94 | 20 | |||
|
|
|
|
|
|
|
|
|
|
|
|
| CNRV*3014A** | 0.98 | 0.94 | 12 | CNRH*3017A** | 0.98 | 0.93 | 20 | |||
|
|
|
|
|
|
|
|
|
|
|
|
| CSRH*2412A** | 0.99 | 0.94 | 12 | CSRH*2412A** | 0.99 | 0.94 | 20 | |||
|
|
|
|
|
|
|
|
|
|
|
|
| CSRH*3012A** | 0.98 | 0.94 | 12 | CSRH*3012A** | 0.98 | 0.93 | 20 | |||
| CAR**2417A** | 0.98 | 0.94 | 16 |
| CNRH*2417A** | 0.99 | 0.93 | 20 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| CAR**3017A** | 0.98 | 0.93 | 16 | CNRH*3017A** | 0.98 | 0.93 | 20 | |||
|
|
|
|
|
|
|
|
|
|
|
|
| CNRH*2417A** | 0.99 | 0.93 | 16 | CSRH*2412A** | 0.99 | 0.93 | 20 | |||
| CNRH*3017A** | 0.98 | 0.93 | 16 |
| CSRH*3012A** | 0.98 | 0.93 | 20 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| CNRV*2417A** | 0.99 | 0.93 | 16 | CNRH*2417A** | 0.99 | 0.95 | 20 | |||
|
|
|
|
|
|
|
|
|
|
|
|
| CNRV*3017A** | 0.98 | 0.93 | 16 | CNRH*3017A** | 0.98 | 0.94 | 20 | |||
| CSRH*2412A** | 0.99 | 0.93 | 16 |
| CSRH*2412A** | 0.99 | 0.95 | 20 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| CSRH*3012A** | 0.98 | 0.93 | 16 | CSRH*3012A** | 0.98 | 0.94 | 20 | |||
| CNRH*2417A** | 0.99 | 0.94 | 20 |
| CAR**2417A** | 0.99 | 0.95 | 14 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| CNRH*3017A** | 0.98 | 0.93 | 20 | CAR**3017A** | 0.98 | 0.94 | 14 | |||
|
|
|
|
|
|
|
|
|
|
|
|
Heating Indoor Model | Capacity | Power | Furnace Model |
CNRV*2417A** | 0.99 | 0.94 | |
|
|
|
|
CNRV*3017A** | 0.98 | 0.93 |
See notes on page 30
25HCR3C