PHYSICAL DATA
UNIT |
|
| |||||||
Operating Weight lb (kg) | 207 | 204 | 211 |
| 252 |
| 239 | 314 | 361 |
(93.9) | (92.5) | (95.7) |
| (114.3) |
| (108.4) | (142.4) | (163.8) | |
|
|
| |||||||
Shipping Weight lb (kg) | 218 | 236 | 222 |
| 287 |
| 250 | 348 | 395 |
(98.9) | (107.1) | (100.7) |
| (130.2) |
| (113.4) | (157.9) | (179.2) | |
|
|
| |||||||
Compressor Type |
|
|
|
| Scroll |
|
|
|
|
REFRIGERANT |
|
| Freon |
|
|
| |||
Control |
|
| TXV |
|
|
| |||
Charge lb (kg) | 7 | 7 | 6.8 |
| 8.1 |
| 9.5 | 13.5 | 16.5 |
(3.2) | (3.2) | (3.1) |
| (3.7) |
| (4.3) | (6.1) | (7.5) | |
|
|
| |||||||
COND FAN |
|
|
|
|
|
|
|
|
|
Air Discharge |
|
|
|
| Vertical |
|
|
|
|
Air Qty (CFM) | 2233 | 2614 | 3167 |
| 3334 |
| 3334 | 4046 | 4046 |
Motor HP | 1/12 | 1/10 | 1/5 |
| 1/8 |
| 1/8 | 1/4 | 1/4 |
Motor RPM | 800 | 800 | 800 |
| 800 |
| 800 | 800 | 800 |
COND COIL |
|
|
|
|
|
|
|
|
|
Face Area (Sq ft) | 19.4 | 21.56 | 19.40 |
| 25.15 |
| 17.60 | 25.15 | 30.18 |
Fins per In. | 20 | 20 | 20 |
| 20 |
| 20 | 20 | 20 |
Rows | 1 | 1 | 1 |
| 1 |
| 2 | 2 | 2 |
Circuits | 5 | 6 | 6 |
| 6 |
| 8 | 8 | 11 |
VALVE CONNECT. (In.) ID |
|
|
|
|
|
|
|
|
|
Vapor | 5/8” | 5/8” | 3/4” |
| 3/4” |
| 7/8” | 7/8” | 7/8” |
Liquid |
|
|
|
| 3/8” |
|
|
|
|
REFRIGERANT TUBES* (in.)OD |
|
|
|
|
|
|
|
|
|
Vapor | 5/8” | 5/8” | 3/4” |
| 3/4” |
| 7/8” | 7/8” | |
Liquid |
|
|
|
| 3/8” |
|
|
|
|
*For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline. Note: See unit Installation Instruction for proper installation.
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
LONG LINE APPLICATION: An application is considered ”Long |
| when outdoor unit is above indoor unit, and 60 ft. (18.29 m) when | ||||||||||||
line” when the total equivalent tubing length exceeds 80 ft. (24.38 |
| the outdoor unit is below the indoor unit. Refer to Accessory | ||||||||||||
m) or when there is more than 20 ft. (6.09 m) vertical separation |
| Usage Guideline below for required accessories. See Longline | ||||||||||||
between indoor and outdoor units. These applications require |
| Application Guideline for required piping and system | ||||||||||||
additional accessories and system modifications for reliable system |
| modifications. Also, refer to the table below for the acceptable | ||||||||||||
operation. The maximum allowable total equivalent length is 250 |
| vapor tube diameters based on the total length to minimize the | ||||||||||||
ft. (76.2 m). The maximum vertical separation is 200 ft. (60.96 m) |
| cooling capacity loss. |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Acceptable |
|
|
|
|
| Cooling Capacity Loss (%) |
|
|
|
| |||
Unit Nominal |
|
|
|
| Total Equivalent Line Length ft. (m) |
|
|
|
| |||||
Vapor Line |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Standard Application |
|
| Long Line Application Requires Accessories |
| ||||||||||
Size (Btuh) | Diameters |
|
|
| ||||||||||
| (In.) OD | 25 | 50 | 80 | 80+ |
| 100 | 125 | 150 |
| 175 | 200 | 225 | 250 |
|
| (7.62) | (15.24) | (24.38) | (24.38+) |
| (30.48) | (38.10) | (45.72) |
| (53.34) | (60.96) | (68.58) | (76.2) |
18,000 | 5/8 | 0 | 1 | 1 | 1 |
| 2 | 3 | 3 |
| 4 | 5 | 5 | 6 |
3/4 | 0 | 0 | 0 | 0 |
| 0 | 1 | 1 |
| 1 | 1 | 2 | 2 | |
24,000 | 5/8 | 0 | 1 | 3 | 3 |
| 3 | 5 | 6 |
| 7 | 8 | 9 | 10 |
3/4 | 0 | 0 | 0 | 0 |
| 1 | 1 | 1 |
| 2 | 2 | 3 | 3 | |
|
| |||||||||||||
7/8 | 0 | 0 | 0 | 0 |
| 0 | 0 | 0 |
| 0 | 1 | 1 | 1 | |
|
|
| ||||||||||||
30,000 | 5/8 | 1 | 3 | 5 | 5 |
| 6 | 8 | 10 |
| 11 | 13 | 15 | 17 |
3/4 | 0 | 1 | 1 | 1 |
| 2 | 3 | 3 |
| 4 | 5 | 5 | 6 | |
|
| |||||||||||||
7/8 | 0 | 0 | 0 | 0 |
| 1 | 1 | 1 |
| 2 | 2 | 2 | 3 | |
|
|
| ||||||||||||
36,000 | 3/4 | 0 | 1 | 2 | 2 |
| 3 | 4 | 5 |
| 6 | 7 | 8 | 9 |
7/8 | 0 | 0 | 1 | 1 |
| 1 | 2 | 2 |
| 3 | 3 | 4 | 4 | |
42,000 | 3/4 | 1 | 2 | 3 | 3 |
| 4 | 5 | 7 |
| 8 | 9 | 10 | 11 |
7/8 | 0 | 1 | 1 | 1 |
| 2 | 2 | 3 |
| 4 | 4 | 5 | 5 | |
48,000 | 3/4 | 1 | 2 | 4 | 4 |
| 5 | 7 | 8 |
| 10 | 11 | 13 | 14 |
7/8 | 0 | 1 | 2 | 2 |
| 2 | 3 | 4 |
| 5 | 5 | 6 | 7 | |
|
| |||||||||||||
0 | 0 | 0 | 0 |
| 0 | 0 | 1 |
| 1 | 1 | 1 | 1 | ||
|
|
| ||||||||||||
60,000 | 7/8 | 1 | 2 | 3 | 3 |
| 4 | 5 | 7 |
| 8 | 9 | 10 | 11 |
0 | 0 | 1 | 1 |
| 1 | 1 | 2 |
| 2 | 2 | 3 | 3 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard Length = 80 ft. (24.38 m) or less total equivalent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines
25HCR3C