TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

NOTE: Meets the ENERGY STAR® guidelines when DualBrite® function is off and ON-TIME is 1 or 5 mi- nutes.

Turn the RANGE control to the medium position (halfway between MIN and MAX), DualBrite® to OFF, and the ON-TIME control to the TEST position.

LAMP MODE

NORMAL SOFT FLASH

 

 

 

 

 

ON-TIME

DUAL BRITE™

MIN

 

 

 

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

OFF 3 6 DUSK TO

RANGE

 

 

 

MINUTES

 

HOUR DAWN

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or unwanted traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

270°

8 ft.

(2.4 m)

70 ft. 100 ft.

(21 m) (30.5 m) Boosted

Maximum Range

Maximum

 

Coverage Angle

NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

The detector is less sensitive to motion directly towards it.

Motion

Sensor

Least Sensitive

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected).Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 2" (51 mm) away from the lamps.

Adjust the RANGE as needed.

RANGE set too high may increase false triggering.

Secure the sensor head by tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes).

Set the DualBrite® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).

Set the LAMP MODE switch to the desired light turn-on effect (Normal, Soft, Flash).

WARNING - Risk of fire. Do not aim the bulbs at a combustible surface within 3 ft. (1 m).

598-1315-02

Image 4
Contents Operation FeaturesRequirements Mode Switching Summary DualBrite TimerFixture operate at high temperatures Lamp ModesWire the Light Control Bulb InstallationMount the Light Control Test and Adjustment Turn on the circuit breaker and light switchAvoid aiming the control at Secure the sensor head by tightening the clamp screwSpecifications Troubleshooting GuideTechnical Service No Service Parts Available for this ProductFuncionamiento DualBriteCaracterísticas RequisitosInstalacion Luz de Adorno DualBriteFases de Lámpara Para Modo ManualInstalación de Bombilla Conecte el Control de LuzInstale el Control de Luz Negro a Negro Blanco a BlancoPrueba Y Ajuste Prenda el cortacircuitos y el interruptor de luzEvite apuntar del detector hacia Mm de las lámparasGuia DE Investigacion DE Averias EspecificacionesAngulo de detección . Hasta Servicio Técnico No hay piezas de servicio disponibles para este productoCaractéristiques FonctionnementExigences Installation Résumé du mode de commutationMinuterie DualBrite Modes D’ÉclairageMontage de la Commande D’Éclairage Installation de L’ampouleNoir / Noir Blanc / Blanc Bride de montage Éviter de pointer l’appareil Essais ET RéglagesSur de grands objets clairs à proximité qui réflé Fiche Technique Guide DE DépannageService Technique Aucune pièce de rechange n’est disponible pour ce produit598-1315-02 Date of Purchase