To Replace Regulator

1.Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section.

2.Set the On/Auto/Off lever to "Off" and unplug unit.

3.Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator.

4.Remove the regulator.

Quick

Outlet Pressure Gauge

Connect

 

Regulator

5.Apply pipe sealant tape to the nipple on the standpipe.

Regulator

Regulator

Nipple

Arrow

6.Assemble the regulator and orient as shown.

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

7.Reapply pipe sealant to outlet pressure gauge and quick connect.

8.Reassemble outlet pressure gauge and quick connect. Orient outlet

pressure gauge to read correctly. Tighten connect with wrench.

A10260

22- ENG

Image 22
Contents Oillube Single-Stage Portable Compressor Safety Guidelines Definitions Important Safety InstructionsHazard Attachments & Accessories Electricity. Like any other electrically Hazard Warning Risk from Moving Parts Equip area of operation with a fire extinguisher Glossary SpecificationsAccessories Duty CycleTo Install Handle AssemblyTools Required for Assembly UnpackingTo Assemble Wheels Assemble Rubber FeetTo Add Oil To Pump Installation Location of the Air CompressorVoltage and Circuit Protection Extension Cords120/240 Dual Voltage Motor Know Your Air Compressor OperationDescription of Operation How to Use Your Unit Before StartingHow to Start Before Each Start-UpMaintenance Customer ResponsibilitiesChecking ChangingAir Filter Inspection and Replacement To Replace BeltMotor Pulley/Flywheel Alignment Service and Adjustments To Replace or Clean Check ValveTo Replace Regulator Storage Troubleshooting Problem Cause CorrectionWhile accessory is being Problem Cause Correction Problem Cause Correction Limited Warranty