Oki C5510 instruction manual To Add Oil To Pump

Page 11

To Add Oil To Pump

Compressors are shipped without oil. A small amount of oil may be present in the pump upon receipt of the air

compressor. This is due to plant testing and does not mean the pump contains oil. Do not attempt to operate this air compressor without first adding oil to the crankcase. Serious damage can result from even limited operation unless filled with oil and broken in correctly. Make sure to closely follow initial start-up procedures.

Multi-Viscosity motor oils, like 10W30, should not be used in an air compressor. They leave carbon deposits on

critical components, thus reducing performance and compressor life. Use air compressor oil only.

NOTE: Oil is included with some units. If oil is not included, use an oil specifically formulated for use in an air compressor, such as Porter-Cable PAS1 air compressor oil. Oil may be found at the store where the air compressor was purchased.

1.Place unit on a level surface.

Risk from Flying Object. Drain tank to release air pressure before removing the dipstick. See "To Drain Tank" in the

"Maintenance" section.

2.Remove oil fill plug (A) and slowly add a compressor oil until it is even with the top of the oil fill hole. NOTE: Do not allow oil to be lower than 3/8" (6 threads) from the top at any time. When filling the crankcase, the oil flows very slowly into the pump. If the oil is added too quickly, it will overflow and appear to be full. NOTE: Crankcase oil capacity is approximately 16 fluid ounces.

3.Replace oil fill plug.

A

11- ENG

A10260

Image 11
Contents Oillube Single-Stage Portable Compressor Important Safety Instructions Safety Guidelines DefinitionsHazard Attachments & Accessories Electricity. Like any other electrically Hazard Warning Risk from Moving Parts Equip area of operation with a fire extinguisher Duty Cycle SpecificationsAccessories GlossaryUnpacking AssemblyTools Required for Assembly To Install HandleAssemble Rubber Feet To Assemble WheelsTo Add Oil To Pump Location of the Air Compressor Installation120/240 Dual Voltage Motor Extension CordsVoltage and Circuit Protection Description of Operation OperationKnow Your Air Compressor Before Starting How to Use Your UnitBefore Each Start-Up How to StartCustomer Responsibilities MaintenanceChanging CheckingTo Replace Belt Air Filter Inspection and ReplacementMotor Pulley/Flywheel Alignment To Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator Storage Problem Cause Correction TroubleshootingWhile accessory is being Problem Cause Correction Problem Cause Correction Limited Warranty