SERVICE AND ADJUSTMENTS

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.

Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

To Replace or Clean Check Valve

1.Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section.

2.Unplug air compressor.

3.Using an adjustable wrench loosen outlet tube nut at air tank and pump. Carefully move outlet tube up away from check valve.

4.Using an adjustable wrench loosen pressure relief tube nut at air tank and pressure switch. Carefully move pressure relief tube away from check valve.

5.Unscrew the check valve (turn counterclockwise) using a 7/8" open end wrench. Note the orientation for reassembly.

Outlet Tube

Pressure

Relief Tube

Nuts

Nuts

Check Valve

6.Using a screwdriver, carefully push the valve disc up and down. NOTE: The valve disc should move freely up and down on a spring which holds

the valve disc in the closed position,

 

if not the check valve needs to be

In open

cleaned or replaced.

position

7. Clean or replace the check valve.

nothing is

A solvent, such as paint or varnish

visible.

remover can be used to clean the

 

check valve.

 

Screwdriver

In closed position disc is visible.

8.Apply sealant to the check valve

threads. Reinstall the check valve (turn clockwise).

9.Replace the pressure release tube. Tighten nuts.

10.Replace the outlet tube and tighten nuts.

11.Perform the Break-in Procedure. See "Break-in Procedure" in the "Operation" section.

21- ENG

A10260

Image 21
Contents Oillube Single-Stage Portable Compressor Important Safety Instructions Safety Guidelines DefinitionsHazard Attachments & Accessories Electricity. Like any other electrically Hazard Warning Risk from Moving Parts Equip area of operation with a fire extinguisher Accessories SpecificationsGlossary Duty CycleTools Required for Assembly AssemblyTo Install Handle UnpackingAssemble Rubber Feet To Assemble WheelsTo Add Oil To Pump Location of the Air Compressor InstallationExtension Cords Voltage and Circuit Protection120/240 Dual Voltage Motor Operation Know Your Air CompressorDescription of Operation Before Starting How to Use Your UnitBefore Each Start-Up How to StartCustomer Responsibilities MaintenanceChanging CheckingTo Replace Belt Air Filter Inspection and ReplacementMotor Pulley/Flywheel Alignment To Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator Storage Problem Cause Correction TroubleshootingWhile accessory is being Problem Cause Correction Problem Cause Correction Limited Warranty