TROUBLESHOOTING
Troubleshooting
ELECTRIC MOTOR.
Application: DFG/E Series SURFACE GRINDER.
MOTOR FAILS TO START
ON/OFF switch in the OFF position. Turn the switch to the ON position.
Improper voltage selection. Determine the available voltage value from the power source. Move the voltage selection switch located on the motor to the proper selection.
SURFACE GRINDER and/or extension cord is not plugged into the power source. Determine that all electrical connections have been properly made. The NEMA
Improper extension cord size and capacity. Operate the SURFACE GRINDER with copper stranded, 8 AWG or larger extension cords. Improper extension cord size and capacity will result in significant heat rise and corresponding voltage and amperage drop.
Thermal protection device activated. To protect the motor against heat related damage, an automatic thermal protection switch is provided near the voltage selection switch. High operating temperatures will activate the switch and shut the motor off. After the motor has cooled to an acceptable temperature level,depress the switch to restart.
ELECTRIC MOTOR LOSES POWER
Improper extension cord size and capacity. Replace with cords meeting the required specifications.
Excessive extension cord length. Even with proper extension cord size and capacity, excessive cord length can reduce the available voltage and amperage to the motor. Measure the available voltage to the motor where the extension cord connects to the SURFACE GRINDER with a voltmeter. Reduce the extension cored length as required to achieve the minimum voltage operating specification as required by the motor manufacturer.
Insufficient available voltage and amperage at the power source. Measure the available voltage at the power source (usually a receptacle) with a voltmeter. If the available voltage is below the minimum operating specification as required by the motor manufacturer, utilize an alternative power source.
Improper motor cooling. See ELECTRIC MOTOR SERVICE.
Excessive load to the motor. See OPERATING THE SURFACE GRINDER ON THE JOBSITE.
ENGINE.
Application: DFG/G Series SURFACE GRINDERS.
ENGINE FAILS TO START
Ignition switch in OFF or cut off position. Place switch in the ON position or move throttle control lever to the ignition operational position.
Incorrect carburetor/fuel ignition system adjustment. See SERVICE section.
Air filter blocked. See SERVICE section.
Ignition wire to spark plug loose or disconnected. Reconnect.
Application: DFG/G Series SURFACE GRINDER.
Fuel supply exhausted. Refill the fuel tank.
Spark plug fouled. Replace Spark Plug. Refill the fuel tank.
ENGINE LOSES POWER
Incorrect carburetor/fuel injection adjustment. See SERVICE section.
Excessive carbon accumulation in combustion chamber. See SERVICE section.
Excessive material
Application: DFG/G Series SURFACE GRINDER.
Water in fuel supply. Drain and replace fuel.
Fuel tank breather vent closed (if so equipped). Open vent.
Air filter blocked. See SERVICE section.