Stow 8FP manual Transporting the Floor Planer

Page 24

ASSEMBLY INSTRUCTIONS/OPERATIONS

3)Using the wrench, remove the four (4) 1/2-inch diameter x 1 inch long capscrews and flat washers securing the drum access plate to the main frame.

4)Remove the drum access plate from the driveshaft.

5)Clean and remove any excessive material build-up from the threaded bosses and surrounding areas.

6)Install the loaded flail drum on the driveshaft. If utilizing the milling flails or other flail configurations that are unidirectional, determine that the flails are facing the direction of rotation. FIGURE 22.

7)Install the drum access plate on the driveshaft. The left, vertical side of the access plate should align tight against the main frame.

8)Install the four 1/2-inch diameter x 1 inch long cap- screws and washers. capscrews should install with a minimal amount of resistance and related, alignment problems. Torque the capscrews to 85 ft lbs (115 N.m). No lockwashers or similar devices are required.

9)If the Floor Planer is powered by an engine, reconnect the engine spark plug wire. If powered by an electric motor and the machine is to be used immediately, reconnect the extension cord of Floor Planer to the power source. Determine that the ON/OFF switch located on the operator handle is in the OFF position.

DANGER

UNEXPECTED MACHINE START UP CAN RESULT IN PROPERTY DAMAGE AND/OR PERSONAL INJURY.

10)Removing a loaded drum from the driveshaft is accomplished by reversing the above steps.

FIGURE 22

TRANSPORTING THE FLOOR PLANER.

Application: All Models.

The Floor Planer has an operational weight that prohibits one person from loading and/or unloading it alone by conventional, physical efforts.

DANGER

DO NOT ATTEMPT TO LIFT THE FLOOR PLANER UP INTO A TRANSPORTATION VEHICLE WITH THE USE OF ONE PERSON ALONE. DO NOT ATTEMPT TO LOWER THE FLOOR PLANER FROM A TRANSPORTATION VEHICLE WITH THE USE OF ONE PERSON ALONE. LIFT AND/OR LOWER THE FLOOR PLANER ONLY BY THE USE OF A POWER TAILGATE UNIT, A SUITABLE HOIST UNIT OF PROPER CAPACITY AND/OR CONFIGURATION OR BY THE USE OF A PROPER QUANTITY OF PERSONNEL IN PROPER PHYSICAL CONDITION.

1)A lifting bail device can be used to facilitate lifting by a mechanical device incorporating a chain and suitable attachment device. The location of the lifting

8FP FLOOR PLANER SERIES

OPERATION AND PARTS MANUAL REV #1 (10/27/06)

PAGE 24

 

 

 

Image 24
Contents Electric and Gasoline Floor Planers Model 8FP Series Page Table of Contents Table of Contents Page Ordered ViaFax 10% Web Stow Construction EquipmentPage Page Operator Instructional Data Sheet Safety Precautions Safety Precautions Operation MAINTENANCE, Repair and Storage Removing the Floor Planer from the Pallet Application All ModelsFilling the 8FP/G Series Engine Fuel Tank Theory of Operation Flail Design and ApplicationStar Flail Beam FlailPentagonal Flail Milling FlailSpacer Washers Function of Spacer WashersProblems encountered by uneven component wear Assembly INSTRUCTIONS/OPERATIONS Flail Drum Design and ApplicationInstalling Flails on the TWO Section Drum General Notes Regarding Flail DrumsNormal installation procedure for milling flails General Notes Regarding the Installation of Flails Installing a Loaded Drum on the DriveshaftTransporting the Floor Planer Assembly INSTRUCTIONS/OPERATIONS Assembly INSTRUCTIONS/OPERATIONS Operating the Floor Planer on the JOB Site Assembly INSTRUCTIONS/OPERATIONS Assembly INSTRUCTIONS/OPERATIONS Assembly INSTRUCTIONS/OPERATIONS Stopping the 8FP/E Series Electrically Powered Floor Planer Stopping the 8FP/G Series Gasoline Powered Floor PlanerPreventative Maintenance Check LIST. Application All Models Observe all applicable safety precautions for the solvent Installing a Replacement V-BELT or Pulley Application As SpecifiedAssembly INSTRUCTIONS/OPERATIONS Application All Models Assembly INSTRUCTIONS/OPERATIONS Assembly INSTRUCTIONS/OPERATIONS Assembly INSTRUCTIONS/OPERATIONS Parts Required Each, container of dry film lubricant Aligning the Caster Wheels Checking Driveshaft RUN OUT Page MAINTENANCE/SERVICE Engine ServiceApplication 8FP/G Series Floor Planer Troubleshooting Accelerated V-BELT Wear Accelerated Bearing Wear AND/OR FailureUneven Cutting Action Storage StorageFrame GeneralExplanation of Code in Remarks Column Items Found In the Remarks ColumnGX160KQXC9 Qty DescriptionMain Frame Assembly Main Frame AssyMain Frame Assy Part Name QTY FRAME, MainTUBE, Vacuum Axle MountDriveshaft Assembly Driveshaft AssyDriveshaft Assy Part Name QTY. Remarks RING, Retaining ExternalSHEAVE, Driveshaft KEY, SpecialRear Frame Assembly Rear Frame AssyRear Frame Assy Part Name QTY Remarks PIN, Roll 3/16 X 1 PlatedBUSHING, Connex SHAFT, Hinge PlatedOperator Handle Assembly Gasoline Operator Handle Assy GasolineBOOT, Rubber BARREL, AdjustingSWITCH, SHUT-OFF TAP, 22-18 Guage WireGasoline Engine Assembly Gasoline Engine AssyPart Name QTY. Remarks FRAME, Main GX160KQXC9 ENGINE, Honda 5.5HPDrive Pulley BUSHING, Center HUBOperator Handle Assembly Electric Operator Handle AssyHeight Adjustment Screw Adjusting Tube Switch MountHOUSING, Switch SWITCH, ON/OFFElectric Motor Assembly Electric Motor AssyMOTOR, Electric 5HP Motor PlateRELIEF, Strain NUT, BulklheadONE Section Drum Assembly ONE Section Drum AssyONE Section Drum Assy Part Name Flail Drum END CAPFlail Drum ROD WASHER, Lock 1/4TWO Section Drum Assembly TWO Section Drum AssyTWO Section Drum Assy Part Name Flail Drum 2 SectionFLAILS, Spacers and Washers Assembly Flails & Spacer Washers AssyFLAILS, Spacers and Washers Assy Part Name QTY Star FlailSpacer Washer Beam FlailDecals Decals Part Name QTY Remarks Decal Warning FlailsDecal Depth Control Dclsdp Decal Stow Large Decalwarning GuardsSpecial Expediting Service PRICING, Rebates SpecificationsPayment Terms Freight PolicyPage Heres HOW to GET Help