Aquacal H/AT120R, H/AT100R owner manual Water in & OUT Connections

Page 15

Plumbing Schematics–Flow 70-GPM and Below

(continued)

Water IN & OUT Connections:

For proper operation and maximum efficiency, piping coming from the pump and filter MUST be connected to the "IN" port of the heater. Likewise, connect piping returning to the pool/spa to the "OUT" port of the heater. See drawing below.

PLUMBING CONNECTION DETAIL

From Pump/Filter

Return to Pool/Spa

15

Image 15
Contents Pool and Spa Heat Pump Installation Guide Page Table of Contents Table of Contents Eam Icebreaker Heat Pump Water Temperature Safety Safety InformationHeater not Repairable by Owner Water Chemistry SafetyStart Up Setting the Temperature Controls Pool or SpaSwitching Controls from Pool to Spa HEATING-QUICK Start & StopPhysical Characteristics Specifications Data Plate Nomenclature Specifications H/AT100R & 120R ModelsOutdoor Installation InstallationPlacement of Heater Indoor InstallationOverview Irrigation, Rainwater Runoff, and Landscape FeaturesEquipment Pad Requirements Anchoring Heater to PadPlumbing Schematics-Flow 70-GPM and Below Plumbing Schematic-Flow Exceeding 70-GPMWater in & OUT Connections Code-Specific Requirements Connecting External ControllersElectrical Requirements General RequirementsGetting Familiar with Controls START-UP & OperationInitial Start-Up and Basic Operation Overview of ControlsReturn Pump Timer Controls to Normal Settings Pool and Spa Combination Heating Heating TipsHeating in Cooler Weather Defrost Cycle Pool/Spa BlanketsCalculating Initial Heating Time Maintenance Planned Maintenance Program20-Point Planned Maintenance Service Includes the Following General Maintenance During the Swim Season Seasonal USE & Shut DownMaintaining Proper Water Flow Maintaining Proper Clearances Around HeaterWinterizing a Heat Pump Equipped with an Internal Drain Winterizing Hard Freeze ConditionsInternal Winterizing Drain Winterizing a Heat Pump Equipped with an External DrainExternal Winterizing Drain Heat Pump Running but Not Heating TroubleshootingCommon Troubleshooting Issues Heat Pump Not RunningHeater Fails to Operate Troubleshooting Flow ChartsIcebreaker Analog Controls 1/20/04 Heater Running but Not HeatingStart Determining Water Leaks vs. CondensationSee Danger statement Heater Short CyclingTo Adjust a TecMark Switch Water Flow Pressure Switch AdjustmentWater Switch Adjustment Procedure To Adjust a Len Gordon SwitchWater Pressure Switch Adjustment Sequence of Operation Defrost System Description and TroubleshootingOverview Major ComponentsTroubleshooting Defrost System Unit Undercharged Troubleshooting Refrigerant Circuit ProblemsPossible Abnormal Conditions & Related Symptoms Unit OverchargedRefrigerant Circuit Performance Charts Troubleshooting Refrigerant Circuit ProblemsUse of Charts- Information for the Technician Refrigerant Circuit Performance Charts a & B Voltage Models Refrigerant Circuit Performance ChartsRefrigerant Circuit Performance Charts D & H Voltage Models AT100-120XR Replacement PartsContacting the Factory What We Need to Know When You Call UsPage 2737 24th St. North St. Petersburg, FL

H/AT120R, H/AT100R specifications

Aquacal H/AT100R and H/AT120R are leading heat pump models designed to efficiently heat swimming pools while promoting energy savings and environmental sustainability. These units are renowned for their advanced technology and impressive performance, making them a popular choice among pool owners.

One of the standout features of the Aquacal H/AT series is its high-efficiency operation. Both models are equipped with a high-performance compressor and heat exchanger that work together to maximize heat transfer. This efficiency translates into lower energy consumption, which not only reduces utility bills but also minimizes the carbon footprint associated with pool heating.

The H/AT100R and H/AT120R utilize advanced refrigeration technology, integrating state-of-the-art components that enhance their overall reliability and durability. The titanium heat exchanger is particularly noteworthy as it provides exceptional resistance to corrosion, ensuring longevity in various water conditions. This means pool owners can enjoy their heated pools for years without worrying about the negative effects of chemical treatment or saltwater.

Another significant technological innovation in these models is the incorporation of a user-friendly digital control panel. This intuitive interface allows users to easily monitor and adjust the temperature settings, facilitating a customized swimming experience. Moreover, the H/AT series is equipped with a built-in timer, enabling automatic operation to ensure the pool is heated precisely when needed.

Aesthetically, the Aquacal H/AT100R and H/AT120R have been designed with a sleek, compact form factor that allows for easy installation in residential and commercial settings. Their quiet operation is another feature that enhances user experience, offering a tranquil swimming environment without the disruptive noise often associated with conventional heating systems.

In terms of environmental friendliness, both models are designed to utilize eco-friendly refrigerants, aligning with modern regulations and promoting sustainable pool heating solutions. This commitment to sustainability reflects Aquacal's proactive approach to meeting the needs of environmentally-conscious consumers.

In conclusion, the Aquacal H/AT100R and H/AT120R heat pumps are notable for their advanced technology, high energy efficiency, user-friendly operation, and environmentally responsible design. These features come together to provide pool owners with a reliable, effective, and sustainable solution for pool heating, ensuring that they can enjoy their aquatic space year-round without compromising on energy efficiency or environmental impact.