The information in this section is written primarily for the Home Owner, but may also apply to servicing dealers or HVAC service centers. This section con- tains information concerning planned maintenance, proper water flow, main- taining proper clearances, as well as other vital information. Please read this section now, and before calling AquaCal Customer Support (800-786-7751).

Planned Maintenance Program

Just as you would have yearly service performed on your air-conditioning system, regular inspection & maintenance of yourAquaCal heat pump will insure highest operating efficiencies, while also protecting your investment– potentially extending the useful life of your heat pump far beyond the warranty period. Our expertly trained factory service technicians offer comprehensive maintenance procedures that will insure your heat pump operates efficiently and reliably when you need it to.

The 20-Point Planned Maintenance Service Includes the Following:

>Check Water Flow

>Clean Evaporator Coil

>Check Relay Contacts

>Check Capacitor Values

>Check Refrigerant Levels

>Clean Heat Pump Cabinet

>Check Fan Blade Clearances

>Check Flow/Pressure Switch

>Check Electrical Connections

>Check Proper Voltage To Unit

>Oil Fan Motor (As Applicable)

>Check Fan Motor Amperage Draw

>Check Pool & Spa Water Chemistry

>Check and Clean Condensate Drains

>Check Compressor Amperage Draw

>Check Water Pump Amperage Draw

>Acid Wash Source Coil (As Applicable)

>Check Operating Controls and Temperature Sensors

>Check Air Temperature Change Through Evaporator

>Check Water Temperature Change Through Condenser

We recommend allAquaCal heat pump owners take advantage of this annual service starting one year after the installation of the unit. You will be surprised at the minimal cost of this service– the service is very reasonably priced for what is included. For further information, or to schedule Planned Maintenance Service, please contact AquaCal Customer Support at: 1-800-786-7751.

22

Image 22
Contents Pool and Spa Heat Pump Installation Guide Page Table of Contents Table of Contents Eam Icebreaker Heat Pump Safety Information Water Temperature SafetyWater Chemistry Safety Heater not Repairable by OwnerHEATING-QUICK Start & Stop Setting the Temperature Controls Pool or SpaSwitching Controls from Pool to Spa Start UpPhysical Characteristics Specifications Specifications H/AT100R & 120R Models Data Plate NomenclatureIndoor Installation InstallationPlacement of Heater Outdoor InstallationAnchoring Heater to Pad Irrigation, Rainwater Runoff, and Landscape FeaturesEquipment Pad Requirements OverviewPlumbing Schematic-Flow Exceeding 70-GPM Plumbing Schematics-Flow 70-GPM and BelowWater in & OUT Connections General Requirements Connecting External ControllersElectrical Requirements Code-Specific RequirementsSTART-UP & Operation Getting Familiar with ControlsOverview of Controls Initial Start-Up and Basic OperationReturn Pump Timer Controls to Normal Settings Pool/Spa Blankets Heating TipsHeating in Cooler Weather Defrost Cycle Pool and Spa Combination HeatingCalculating Initial Heating Time Planned Maintenance Program Maintenance20-Point Planned Maintenance Service Includes the Following General Maintenance Maintaining Proper Clearances Around Heater Seasonal USE & Shut DownMaintaining Proper Water Flow During the Swim SeasonWinterizing Hard Freeze Conditions Winterizing a Heat Pump Equipped with an Internal DrainWinterizing a Heat Pump Equipped with an External Drain Internal Winterizing DrainExternal Winterizing Drain Heat Pump Not Running TroubleshootingCommon Troubleshooting Issues Heat Pump Running but Not HeatingTroubleshooting Flow Charts Heater Fails to OperateHeater Running but Not Heating Icebreaker Analog Controls 1/20/04Determining Water Leaks vs. Condensation StartHeater Short Cycling See Danger statementTo Adjust a Len Gordon Switch Water Flow Pressure Switch AdjustmentWater Switch Adjustment Procedure To Adjust a TecMark SwitchWater Pressure Switch Adjustment Major Components Defrost System Description and TroubleshootingOverview Sequence of OperationTroubleshooting Defrost System Unit Overcharged Troubleshooting Refrigerant Circuit ProblemsPossible Abnormal Conditions & Related Symptoms Unit UnderchargedTroubleshooting Refrigerant Circuit Problems Refrigerant Circuit Performance ChartsUse of Charts- Information for the Technician Refrigerant Circuit Performance Charts Refrigerant Circuit Performance Charts a & B Voltage ModelsRefrigerant Circuit Performance Charts D & H Voltage Models Replacement Parts AT100-120XRWhat We Need to Know When You Call Us Contacting the FactoryPage 2737 24th St. North St. Petersburg, FL

H/AT120R, H/AT100R specifications

Aquacal H/AT100R and H/AT120R are leading heat pump models designed to efficiently heat swimming pools while promoting energy savings and environmental sustainability. These units are renowned for their advanced technology and impressive performance, making them a popular choice among pool owners.

One of the standout features of the Aquacal H/AT series is its high-efficiency operation. Both models are equipped with a high-performance compressor and heat exchanger that work together to maximize heat transfer. This efficiency translates into lower energy consumption, which not only reduces utility bills but also minimizes the carbon footprint associated with pool heating.

The H/AT100R and H/AT120R utilize advanced refrigeration technology, integrating state-of-the-art components that enhance their overall reliability and durability. The titanium heat exchanger is particularly noteworthy as it provides exceptional resistance to corrosion, ensuring longevity in various water conditions. This means pool owners can enjoy their heated pools for years without worrying about the negative effects of chemical treatment or saltwater.

Another significant technological innovation in these models is the incorporation of a user-friendly digital control panel. This intuitive interface allows users to easily monitor and adjust the temperature settings, facilitating a customized swimming experience. Moreover, the H/AT series is equipped with a built-in timer, enabling automatic operation to ensure the pool is heated precisely when needed.

Aesthetically, the Aquacal H/AT100R and H/AT120R have been designed with a sleek, compact form factor that allows for easy installation in residential and commercial settings. Their quiet operation is another feature that enhances user experience, offering a tranquil swimming environment without the disruptive noise often associated with conventional heating systems.

In terms of environmental friendliness, both models are designed to utilize eco-friendly refrigerants, aligning with modern regulations and promoting sustainable pool heating solutions. This commitment to sustainability reflects Aquacal's proactive approach to meeting the needs of environmentally-conscious consumers.

In conclusion, the Aquacal H/AT100R and H/AT120R heat pumps are notable for their advanced technology, high energy efficiency, user-friendly operation, and environmentally responsible design. These features come together to provide pool owners with a reliable, effective, and sustainable solution for pool heating, ensuring that they can enjoy their aquatic space year-round without compromising on energy efficiency or environmental impact.