Aquacal H/AT100R Seasonal USE & Shut Down, Maintaining Proper Water Flow, During the Swim Season

Page 24

Maintaining Proper Water Flow

It is important to operate and maintain the filter according to the manufacturer's specifications. As a filter gets dirty, the water flow to the heat pump is reduced. The higher the pressure on the filter gauge, the lower the flow rate.

Similar to a dirty filter, large amounts of debris in the pump basket can reduce water flow. Keep basket free of debris.

Check for improper valve settings. Apartially closed valve after the filter, or a full-open bypass around the heater, will cause insufficient water flow through the heater.

If the conditions listed above remain unresolved, the water flow through the heater may be reduced to a point where internal safety devices shut the heater off. Before calling for service, always check the filter, the pump basket, and water valve positions. If the problem persists, call AquaCal Customer Support at: (800) 786-7751.

CAUTION- Pool/Spa Refinishing Operations

During pool refinishing or acid cleaning, the water flow through the heater must be shut off. Water flow to the heater must remain off until water chemistry is once again in balance and the water is clear in appearance. Failure to follow these instructions may void heater warranty.

Maintaining Proper Clearances Around Heater

For maximum efficiency, proper air flow clearances around heater must be maintained.

It is important to keep the area immediately adjacent to the heat pump clear of items such as shrubs and bushes, lawn furniture, chemicals containers, etc. These items can prevent air from circulating fully through the heater, and will result in inefficient operation or damage to components inside the heat

pump. In addition, do not place objects on top of the heat pump; doing so will block the air from exiting the heater, and will result in damage to the compressor and fan motor.

Proper clearances are also necessary in order to access the working parts of your heater. A heater that is easy to "get to," will be a heater that is easy to maintain; service and maintenance personnel will thank you for keeping the area around your heater unobstructed.

Please see: Service, and Operational Clearances, located within the Installation section of this manual, for specific clearance requirements.

SEASONAL USE & SHUT DOWN

During the Swim Season

During the swim season, even if the pool or spa is not in use, allow water to flow through the heater. Doing so eliminates the need to reposition valves when you do wish to heat the pool or spa.

During periods where heating or cooling is not desired, leave POOL/OFF/SPAtoggle switch in the OFF position.

Freeze protection / Extended Shut Down

In areas where freezing conditions are a rare occurrence, allow the filtration system to run continuously through the freeze period. Typically, during light freeze conditions, circulating water will not freeze.

In areas where freezing conditions are prevalent, please refer to winterizing instructions following this section.

24

Image 24
Contents Pool and Spa Heat Pump Installation Guide Page Table of Contents Table of Contents Eam Icebreaker Heat Pump Safety Information Water Temperature SafetyWater Chemistry Safety Heater not Repairable by OwnerSetting the Temperature Controls Pool or Spa Switching Controls from Pool to SpaHEATING-QUICK Start & Stop Start UpPhysical Characteristics Specifications Specifications H/AT100R & 120R Models Data Plate NomenclatureInstallation Placement of HeaterIndoor Installation Outdoor InstallationIrrigation, Rainwater Runoff, and Landscape Features Equipment Pad RequirementsAnchoring Heater to Pad OverviewPlumbing Schematic-Flow Exceeding 70-GPM Plumbing Schematics-Flow 70-GPM and BelowWater in & OUT Connections Connecting External Controllers Electrical RequirementsGeneral Requirements Code-Specific RequirementsSTART-UP & Operation Getting Familiar with ControlsOverview of Controls Initial Start-Up and Basic OperationReturn Pump Timer Controls to Normal Settings Heating Tips Heating in Cooler Weather Defrost CyclePool/Spa Blankets Pool and Spa Combination HeatingCalculating Initial Heating Time Maintenance Planned Maintenance Program20-Point Planned Maintenance Service Includes the Following General Maintenance Seasonal USE & Shut Down Maintaining Proper Water FlowMaintaining Proper Clearances Around Heater During the Swim SeasonWinterizing Hard Freeze Conditions Winterizing a Heat Pump Equipped with an Internal DrainWinterizing a Heat Pump Equipped with an External Drain Internal Winterizing DrainExternal Winterizing Drain Troubleshooting Common Troubleshooting IssuesHeat Pump Not Running Heat Pump Running but Not HeatingTroubleshooting Flow Charts Heater Fails to OperateHeater Running but Not Heating Icebreaker Analog Controls 1/20/04Determining Water Leaks vs. Condensation StartHeater Short Cycling See Danger statementWater Flow Pressure Switch Adjustment Water Switch Adjustment ProcedureTo Adjust a Len Gordon Switch To Adjust a TecMark SwitchWater Pressure Switch Adjustment Defrost System Description and Troubleshooting OverviewMajor Components Sequence of OperationTroubleshooting Defrost System Troubleshooting Refrigerant Circuit Problems Possible Abnormal Conditions & Related SymptomsUnit Overcharged Unit UnderchargedRefrigerant Circuit Performance Charts Troubleshooting Refrigerant Circuit ProblemsUse of Charts- Information for the Technician Refrigerant Circuit Performance Charts Refrigerant Circuit Performance Charts a & B Voltage ModelsRefrigerant Circuit Performance Charts D & H Voltage Models Replacement Parts AT100-120XRWhat We Need to Know When You Call Us Contacting the FactoryPage 2737 24th St. North St. Petersburg, FL

H/AT120R, H/AT100R specifications

Aquacal H/AT100R and H/AT120R are leading heat pump models designed to efficiently heat swimming pools while promoting energy savings and environmental sustainability. These units are renowned for their advanced technology and impressive performance, making them a popular choice among pool owners.

One of the standout features of the Aquacal H/AT series is its high-efficiency operation. Both models are equipped with a high-performance compressor and heat exchanger that work together to maximize heat transfer. This efficiency translates into lower energy consumption, which not only reduces utility bills but also minimizes the carbon footprint associated with pool heating.

The H/AT100R and H/AT120R utilize advanced refrigeration technology, integrating state-of-the-art components that enhance their overall reliability and durability. The titanium heat exchanger is particularly noteworthy as it provides exceptional resistance to corrosion, ensuring longevity in various water conditions. This means pool owners can enjoy their heated pools for years without worrying about the negative effects of chemical treatment or saltwater.

Another significant technological innovation in these models is the incorporation of a user-friendly digital control panel. This intuitive interface allows users to easily monitor and adjust the temperature settings, facilitating a customized swimming experience. Moreover, the H/AT series is equipped with a built-in timer, enabling automatic operation to ensure the pool is heated precisely when needed.

Aesthetically, the Aquacal H/AT100R and H/AT120R have been designed with a sleek, compact form factor that allows for easy installation in residential and commercial settings. Their quiet operation is another feature that enhances user experience, offering a tranquil swimming environment without the disruptive noise often associated with conventional heating systems.

In terms of environmental friendliness, both models are designed to utilize eco-friendly refrigerants, aligning with modern regulations and promoting sustainable pool heating solutions. This commitment to sustainability reflects Aquacal's proactive approach to meeting the needs of environmentally-conscious consumers.

In conclusion, the Aquacal H/AT100R and H/AT120R heat pumps are notable for their advanced technology, high energy efficiency, user-friendly operation, and environmentally responsible design. These features come together to provide pool owners with a reliable, effective, and sustainable solution for pool heating, ensuring that they can enjoy their aquatic space year-round without compromising on energy efficiency or environmental impact.