Aquacal H/AT120R owner manual Specifications H/AT100R & 120R Models, Data Plate Nomenclature

Page 11

Specifications — H/AT100R & 120R Models

100-SERIES:

H100AR

H100BR

 

H100DR

H100HR

AT100AR

AT100BR

 

AT100DR

AT100HR

 

 

BTU - 80%RH

 

 

 

 

 

Air ºF / Air ºF… 80/50

88,000/63,000

 

 

 

 

COP

5.6/4.1

(DATA

 

 

 

 

 

 

 

COP

5.3/3.9

 

 

PEND

ING)

BTU - 63% RH

 

 

 

 

 

Air ºF / Air ºF… 80/50

83,000/57,000

 

 

 

 

 

 

 

 

 

 

Kilowatt Input (80% RH)

4.6

 

 

 

 

Voltage/Hz/Phase

208-230/60/1

208-230/60/3

380-415/50/3

220-240/50/1

Min. Circuit Ampacity

38.16

22.13

 

11.62

26.14

Rec. Fuse or Breaker Size

40

30

 

15

30

Max. Fuse or Breaker Size

60

35

 

20

40

Min-Max Water Flow (gpm)

20-70

20-70

 

20-70

20-70

Shipping weight (lbs)

320

320

 

320

320

Shipping Size (LXWXH)

36” X 40” X 43"

36” X 40” X 43"

36” X 40” X 43"

36” X 40” X 43"

Uncrated Weight

293

293

 

293

293

120-SERIES:

H120AR

H120BR

 

H120DR

H120HR

AT120AR

AT120BR

 

AT120DR

AT120HR

BTU - 80%RH

 

 

 

 

 

COP

5.4/4.1

(DATA

 

 

 

Air ºF / Air ºF… 80/50

103,000/70,000

 

 

 

 

BTU - 63% RH

 

 

 

PENDING)

 

 

 

Air ºF / Air ºF… 80/50

99,000/68,000

 

 

 

 

COP

5/3.8

 

 

 

 

Kilowatt Input (80% RH)

5.6

 

 

 

 

Voltage/Hz/Phase

208-230/60/1

208-230/60/3

380-415/50/3 220-240/50/1

Min. Circuit Ampacity

38.16

26.14

 

12.82

36.56

Rec. Fuse or Breaker Size

40

30

 

15

40

Max. Fuse or Breaker Size

60

40

 

20

60

Min-Max Water Flow (gpm)

20-70

20-70

 

20-70

20-70

Shipping weight (lbs)

330

330

 

330

330

Shipping Size (LXWXH)

36” X 40” X 43"

36” X 40” X 43"

36” X 40” X 43"

36” X 40” X 43"

Uncrated Weight

303

303

 

303

303

Data Plate Nomenclature

1

2

3

4

5

6

7

8

9

10

11

12

A T 1

2

0

A R A E W N A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRAND

H =

HeatWave

 

AT=

AeroTemp

 

 

 

 

 

 

SB =

SouthBeach

 

TZ =

Tropez

 

CAPACITY

 

100 =

90000 Btus/hr

 

120 =

109000 Btus/hr

 

 

 

 

155 =

120000 Btus/hr

 

VOLTAGE

A - 1/60/208-230

B - 3/60/208 - 230

D - 3/50/380

H - 1/50/200-220

RFRG CONTROL

H - HEAT

R - REVERSING

CURRENT RELEASED REVISION

A - INITIAL RELEASE

OPTIONS

N-NONE

CABINET COLOR

W - CRÈME

B - BLACK

REFRIGERANT

E - R22

T - R407C

Z - R410A

CONTROLS

A - ANALOG

D - DIGITAL

11

Image 11
Contents Pool and Spa Heat Pump Installation Guide Page Table of Contents Table of Contents Eam Icebreaker Heat Pump Water Temperature Safety Safety InformationHeater not Repairable by Owner Water Chemistry SafetyStart Up Setting the Temperature Controls Pool or SpaSwitching Controls from Pool to Spa HEATING-QUICK Start & StopPhysical Characteristics Specifications Data Plate Nomenclature Specifications H/AT100R & 120R ModelsOutdoor Installation InstallationPlacement of Heater Indoor InstallationOverview Irrigation, Rainwater Runoff, and Landscape FeaturesEquipment Pad Requirements Anchoring Heater to PadPlumbing Schematics-Flow 70-GPM and Below Plumbing Schematic-Flow Exceeding 70-GPMWater in & OUT Connections Code-Specific Requirements Connecting External ControllersElectrical Requirements General RequirementsGetting Familiar with Controls START-UP & OperationInitial Start-Up and Basic Operation Overview of ControlsReturn Pump Timer Controls to Normal Settings Pool and Spa Combination Heating Heating TipsHeating in Cooler Weather Defrost Cycle Pool/Spa BlanketsCalculating Initial Heating Time 20-Point Planned Maintenance Service Includes the Following MaintenancePlanned Maintenance Program General Maintenance During the Swim Season Seasonal USE & Shut DownMaintaining Proper Water Flow Maintaining Proper Clearances Around HeaterWinterizing a Heat Pump Equipped with an Internal Drain Winterizing Hard Freeze ConditionsInternal Winterizing Drain Winterizing a Heat Pump Equipped with an External DrainExternal Winterizing Drain Heat Pump Running but Not Heating TroubleshootingCommon Troubleshooting Issues Heat Pump Not RunningHeater Fails to Operate Troubleshooting Flow ChartsIcebreaker Analog Controls 1/20/04 Heater Running but Not HeatingStart Determining Water Leaks vs. CondensationSee Danger statement Heater Short CyclingTo Adjust a TecMark Switch Water Flow Pressure Switch AdjustmentWater Switch Adjustment Procedure To Adjust a Len Gordon SwitchWater Pressure Switch Adjustment Sequence of Operation Defrost System Description and TroubleshootingOverview Major ComponentsTroubleshooting Defrost System Unit Undercharged Troubleshooting Refrigerant Circuit ProblemsPossible Abnormal Conditions & Related Symptoms Unit OverchargedUse of Charts- Information for the Technician Refrigerant Circuit Performance ChartsTroubleshooting Refrigerant Circuit Problems Refrigerant Circuit Performance Charts a & B Voltage Models Refrigerant Circuit Performance ChartsRefrigerant Circuit Performance Charts D & H Voltage Models AT100-120XR Replacement PartsContacting the Factory What We Need to Know When You Call UsPage 2737 24th St. North St. Petersburg, FL

H/AT120R, H/AT100R specifications

Aquacal H/AT100R and H/AT120R are leading heat pump models designed to efficiently heat swimming pools while promoting energy savings and environmental sustainability. These units are renowned for their advanced technology and impressive performance, making them a popular choice among pool owners.

One of the standout features of the Aquacal H/AT series is its high-efficiency operation. Both models are equipped with a high-performance compressor and heat exchanger that work together to maximize heat transfer. This efficiency translates into lower energy consumption, which not only reduces utility bills but also minimizes the carbon footprint associated with pool heating.

The H/AT100R and H/AT120R utilize advanced refrigeration technology, integrating state-of-the-art components that enhance their overall reliability and durability. The titanium heat exchanger is particularly noteworthy as it provides exceptional resistance to corrosion, ensuring longevity in various water conditions. This means pool owners can enjoy their heated pools for years without worrying about the negative effects of chemical treatment or saltwater.

Another significant technological innovation in these models is the incorporation of a user-friendly digital control panel. This intuitive interface allows users to easily monitor and adjust the temperature settings, facilitating a customized swimming experience. Moreover, the H/AT series is equipped with a built-in timer, enabling automatic operation to ensure the pool is heated precisely when needed.

Aesthetically, the Aquacal H/AT100R and H/AT120R have been designed with a sleek, compact form factor that allows for easy installation in residential and commercial settings. Their quiet operation is another feature that enhances user experience, offering a tranquil swimming environment without the disruptive noise often associated with conventional heating systems.

In terms of environmental friendliness, both models are designed to utilize eco-friendly refrigerants, aligning with modern regulations and promoting sustainable pool heating solutions. This commitment to sustainability reflects Aquacal's proactive approach to meeting the needs of environmentally-conscious consumers.

In conclusion, the Aquacal H/AT100R and H/AT120R heat pumps are notable for their advanced technology, high energy efficiency, user-friendly operation, and environmentally responsible design. These features come together to provide pool owners with a reliable, effective, and sustainable solution for pool heating, ensuring that they can enjoy their aquatic space year-round without compromising on energy efficiency or environmental impact.