Important Features of Your New

Icebreaker Heat Pump

ThermoLink

Heat Exchanger

The heart of your heat pump is the patented ThermoLink heat ex- changer. The primary cause of premature heat pump demise is the failure of the heat exchanger. Ordinary heat exchangers are made from a cupron- ickel alloy. This cupron- ickel material is suscep- tible to attack from the sanitizers used in pools and spas, and from other re- lated water chemistry con- ditions. Once the heat ex- changer fails, the heat pump is ruined. The ThermoLink heat ex- changer tube is made from titanium, and is virtually im- pervious to water chemis- try damage.

ThermoLink

Heat Exchanger

Electronic Controller

Corrosion-Resistant

Cabinet

Scroll Compressor

Heat & Cool + Hot Gas

Defrost

Electronic

Controller

State-of-the-art, solid- state electronic controller, maintains water tempera- ture within 1ºF of set point. Controller also permits user to predefine different Pool and Spa water temperature set points.

Corrosion-Proof

Cabinet

The cabinet, being made from resilient, UV-Pro- tected ABS material, can never rust, fade, or cor- rode. You can expect the cabinet to retain a like- new appearance with only an occasional wash down and—if so desired— a quick waxing.

Scroll Compressor

50% fewer moving parts than standard piston-type compressors. This equates to much improved reliability and improved efficiency. Scroll compressors are also much quieter in operation than piston-type compressors.

Heat & Cool Capability

Puts you in full control, year round ...Warms your pool or spa with the reliability and efficiency of our other heat pumps, but, with the flip of a switch, can also cool your pool or spa to refreshing temperatures during the hot summer months. For cooler climates, Icebreaker heat pumps offer unique advantages over passive defrost models. Please read more below...

Hot Gas, Icebreaker Defrost

Your Icebreaker heat pump is uniquely equipped for active defrost. Active defrost involves directing hot refrig- erant gas to the heat collector, melting accumulated ice away in a matter of a few minutes—then right back to heating. Standard heat pumps may remain “off in defrost” for extended periods during very cold weather. Because of its ability to continue to operate even during freezing weather, your Icebreaker extends the swim- ming season longer than any other heat pump.

PLEASE SPEND A FEW MINUTES READING FURTHER TO BECOME

FAMILIAR WITH ALL THE FEATURES, THE SAFE OPERATION, AND THE

CARE OF YOUR NEW HEAT PUMP.

6

Image 6
Contents Pool and Spa Heat Pump Installation Guide Page Table of Contents Table of Contents Eam Icebreaker Heat Pump Safety Information Water Temperature SafetyWater Chemistry Safety Heater not Repairable by OwnerHEATING-QUICK Start & Stop Setting the Temperature Controls Pool or SpaSwitching Controls from Pool to Spa Start UpPhysical Characteristics Specifications Specifications H/AT100R & 120R Models Data Plate NomenclatureIndoor Installation InstallationPlacement of Heater Outdoor InstallationAnchoring Heater to Pad Irrigation, Rainwater Runoff, and Landscape FeaturesEquipment Pad Requirements OverviewPlumbing Schematic-Flow Exceeding 70-GPM Plumbing Schematics-Flow 70-GPM and BelowWater in & OUT Connections General Requirements Connecting External ControllersElectrical Requirements Code-Specific RequirementsSTART-UP & Operation Getting Familiar with ControlsOverview of Controls Initial Start-Up and Basic OperationReturn Pump Timer Controls to Normal Settings Pool/Spa Blankets Heating TipsHeating in Cooler Weather Defrost Cycle Pool and Spa Combination HeatingCalculating Initial Heating Time Maintenance Planned Maintenance Program20-Point Planned Maintenance Service Includes the Following General Maintenance Maintaining Proper Clearances Around Heater Seasonal USE & Shut DownMaintaining Proper Water Flow During the Swim SeasonWinterizing Hard Freeze Conditions Winterizing a Heat Pump Equipped with an Internal DrainWinterizing a Heat Pump Equipped with an External Drain Internal Winterizing DrainExternal Winterizing Drain Heat Pump Not Running TroubleshootingCommon Troubleshooting Issues Heat Pump Running but Not HeatingTroubleshooting Flow Charts Heater Fails to OperateHeater Running but Not Heating Icebreaker Analog Controls 1/20/04Determining Water Leaks vs. Condensation StartHeater Short Cycling See Danger statementTo Adjust a Len Gordon Switch Water Flow Pressure Switch AdjustmentWater Switch Adjustment Procedure To Adjust a TecMark SwitchWater Pressure Switch Adjustment Major Components Defrost System Description and TroubleshootingOverview Sequence of OperationTroubleshooting Defrost System Unit Overcharged Troubleshooting Refrigerant Circuit ProblemsPossible Abnormal Conditions & Related Symptoms Unit UnderchargedRefrigerant Circuit Performance Charts Troubleshooting Refrigerant Circuit ProblemsUse of Charts- Information for the Technician Refrigerant Circuit Performance Charts Refrigerant Circuit Performance Charts a & B Voltage ModelsRefrigerant Circuit Performance Charts D & H Voltage Models Replacement Parts AT100-120XRWhat We Need to Know When You Call Us Contacting the FactoryPage 2737 24th St. North St. Petersburg, FL

H/AT120R, H/AT100R specifications

Aquacal H/AT100R and H/AT120R are leading heat pump models designed to efficiently heat swimming pools while promoting energy savings and environmental sustainability. These units are renowned for their advanced technology and impressive performance, making them a popular choice among pool owners.

One of the standout features of the Aquacal H/AT series is its high-efficiency operation. Both models are equipped with a high-performance compressor and heat exchanger that work together to maximize heat transfer. This efficiency translates into lower energy consumption, which not only reduces utility bills but also minimizes the carbon footprint associated with pool heating.

The H/AT100R and H/AT120R utilize advanced refrigeration technology, integrating state-of-the-art components that enhance their overall reliability and durability. The titanium heat exchanger is particularly noteworthy as it provides exceptional resistance to corrosion, ensuring longevity in various water conditions. This means pool owners can enjoy their heated pools for years without worrying about the negative effects of chemical treatment or saltwater.

Another significant technological innovation in these models is the incorporation of a user-friendly digital control panel. This intuitive interface allows users to easily monitor and adjust the temperature settings, facilitating a customized swimming experience. Moreover, the H/AT series is equipped with a built-in timer, enabling automatic operation to ensure the pool is heated precisely when needed.

Aesthetically, the Aquacal H/AT100R and H/AT120R have been designed with a sleek, compact form factor that allows for easy installation in residential and commercial settings. Their quiet operation is another feature that enhances user experience, offering a tranquil swimming environment without the disruptive noise often associated with conventional heating systems.

In terms of environmental friendliness, both models are designed to utilize eco-friendly refrigerants, aligning with modern regulations and promoting sustainable pool heating solutions. This commitment to sustainability reflects Aquacal's proactive approach to meeting the needs of environmentally-conscious consumers.

In conclusion, the Aquacal H/AT100R and H/AT120R heat pumps are notable for their advanced technology, high energy efficiency, user-friendly operation, and environmentally responsible design. These features come together to provide pool owners with a reliable, effective, and sustainable solution for pool heating, ensuring that they can enjoy their aquatic space year-round without compromising on energy efficiency or environmental impact.