TROUBLESHOOTING

Common Troubleshooting Issues

Heat Pump Not Running

Is the power light lit?

If not, ensure the main breaker (located at the power supply panel) and the disconnect switch (located near the heat pump) are both turned ON.

Is the flow light lit?

If not, check to be sure that the circulating pump is operating and the filter is clean. There may also be a valve positioned incorrectly allowing water to bypass the heat pump. Be sure water is flowing through the heater.

Is the Pool or Spa thermostat selected, and have you tried turning the selected thermostat to a higher temperature setting?

If not, the actual water temperature may be above that of the selected thermostat. Raise the desired water temperature above the actual water temperature; the heater should start after an approximate five (5) minute delay. If the heat pump still fails to start, and the unit is not in defrost (defrost light lit), contact AquaCal Customer Support: 800-786-7751.

Heat Pump Running but Not Heating

Is the air blowing out of the top of the unit noticeably cooler than the surrounding air?

(A9°F to 12°F difference is typical.) If not, contact AquaCal for service at: 800-786-7751. But first, be sure all air coil surfaces are free from obstructions– low roof overhangs, landscaping, walls, fences, etc., can restrict air flow. The heat pump needs good airflow to operate at peak efficiency.

How many hours/day does the circulating pump operate?

Cooler weather conditions, or heating to a higher temperature, may necessitate running the heat pump for a longer period of time. Was the heater sized considering the use of a solar blanket (check with installing dealer)? A blanket can be useful in permitting shorter run times, in turn leading to substantial energy cost savings.

What is the air temperature?

The heat pump may be in the defrost mode if air temperatures are below 50°F. The defrost light will be lit if the heater is defrosting. If air temperatures are not cold, but the defrost light is still illuminated, contact AquaCal Customer Support at: 800-786-7751.

Water Coming from the Heat Pump

Is it a leak or just condensation from normal operation? Here's how to find out.

Shut the heat pump off, leaving the circulation pump running. Within a few hours, there should be a marked reduction in the amount of water seen around the bottom of the heat pump. If the water appears to be drying up, the water is probably harmless condensate.

Or, as an alternate method, test the water draining out the heater base for the presence of the sanitizer being used in the pool or spa. Using a water test kit, or a test strip, check a sample of the water for chlorine or bromine. If the sample tests positive for sanitizer, call AquaCal for service at: 800-786-7751. If the test is negative, the water is probably harmless condensate.

NOTE: The water test method will not be effective if an ionizer or ozone generator is being used to produce the sanitizing agent.

Please see Troubleshooting Flowcharts, following, for more detailed information.

28

Image 28
Contents Pool and Spa Heat Pump Installation Guide Page Table of Contents Table of Contents Eam Icebreaker Heat Pump Safety Information Water Temperature SafetyWater Chemistry Safety Heater not Repairable by OwnerSetting the Temperature Controls Pool or Spa Switching Controls from Pool to SpaHEATING-QUICK Start & Stop Start UpPhysical Characteristics Specifications Specifications H/AT100R & 120R Models Data Plate NomenclatureInstallation Placement of HeaterIndoor Installation Outdoor InstallationIrrigation, Rainwater Runoff, and Landscape Features Equipment Pad RequirementsAnchoring Heater to Pad OverviewPlumbing Schematic-Flow Exceeding 70-GPM Plumbing Schematics-Flow 70-GPM and BelowWater in & OUT Connections Connecting External Controllers Electrical RequirementsGeneral Requirements Code-Specific RequirementsSTART-UP & Operation Getting Familiar with ControlsOverview of Controls Initial Start-Up and Basic OperationReturn Pump Timer Controls to Normal Settings Heating Tips Heating in Cooler Weather Defrost CyclePool/Spa Blankets Pool and Spa Combination HeatingCalculating Initial Heating Time Planned Maintenance Program Maintenance20-Point Planned Maintenance Service Includes the Following General Maintenance Seasonal USE & Shut Down Maintaining Proper Water FlowMaintaining Proper Clearances Around Heater During the Swim SeasonWinterizing Hard Freeze Conditions Winterizing a Heat Pump Equipped with an Internal DrainWinterizing a Heat Pump Equipped with an External Drain Internal Winterizing DrainExternal Winterizing Drain Troubleshooting Common Troubleshooting IssuesHeat Pump Not Running Heat Pump Running but Not HeatingTroubleshooting Flow Charts Heater Fails to OperateHeater Running but Not Heating Icebreaker Analog Controls 1/20/04Determining Water Leaks vs. Condensation StartHeater Short Cycling See Danger statementWater Flow Pressure Switch Adjustment Water Switch Adjustment ProcedureTo Adjust a Len Gordon Switch To Adjust a TecMark SwitchWater Pressure Switch Adjustment Defrost System Description and Troubleshooting OverviewMajor Components Sequence of OperationTroubleshooting Defrost System Troubleshooting Refrigerant Circuit Problems Possible Abnormal Conditions & Related SymptomsUnit Overcharged Unit UnderchargedTroubleshooting Refrigerant Circuit Problems Refrigerant Circuit Performance ChartsUse of Charts- Information for the Technician Refrigerant Circuit Performance Charts Refrigerant Circuit Performance Charts a & B Voltage ModelsRefrigerant Circuit Performance Charts D & H Voltage Models Replacement Parts AT100-120XRWhat We Need to Know When You Call Us Contacting the FactoryPage 2737 24th St. North St. Petersburg, FL

H/AT120R, H/AT100R specifications

Aquacal H/AT100R and H/AT120R are leading heat pump models designed to efficiently heat swimming pools while promoting energy savings and environmental sustainability. These units are renowned for their advanced technology and impressive performance, making them a popular choice among pool owners.

One of the standout features of the Aquacal H/AT series is its high-efficiency operation. Both models are equipped with a high-performance compressor and heat exchanger that work together to maximize heat transfer. This efficiency translates into lower energy consumption, which not only reduces utility bills but also minimizes the carbon footprint associated with pool heating.

The H/AT100R and H/AT120R utilize advanced refrigeration technology, integrating state-of-the-art components that enhance their overall reliability and durability. The titanium heat exchanger is particularly noteworthy as it provides exceptional resistance to corrosion, ensuring longevity in various water conditions. This means pool owners can enjoy their heated pools for years without worrying about the negative effects of chemical treatment or saltwater.

Another significant technological innovation in these models is the incorporation of a user-friendly digital control panel. This intuitive interface allows users to easily monitor and adjust the temperature settings, facilitating a customized swimming experience. Moreover, the H/AT series is equipped with a built-in timer, enabling automatic operation to ensure the pool is heated precisely when needed.

Aesthetically, the Aquacal H/AT100R and H/AT120R have been designed with a sleek, compact form factor that allows for easy installation in residential and commercial settings. Their quiet operation is another feature that enhances user experience, offering a tranquil swimming environment without the disruptive noise often associated with conventional heating systems.

In terms of environmental friendliness, both models are designed to utilize eco-friendly refrigerants, aligning with modern regulations and promoting sustainable pool heating solutions. This commitment to sustainability reflects Aquacal's proactive approach to meeting the needs of environmentally-conscious consumers.

In conclusion, the Aquacal H/AT100R and H/AT120R heat pumps are notable for their advanced technology, high energy efficiency, user-friendly operation, and environmentally responsible design. These features come together to provide pool owners with a reliable, effective, and sustainable solution for pool heating, ensuring that they can enjoy their aquatic space year-round without compromising on energy efficiency or environmental impact.