G1018 Table Stops
The Model G1018 has table stop bolts (see Figure 34) that can be set to repeatedly bring the table back to 0 on the depth indicator scale. These table stop bolts are located directly under both table adjustment levers. If you do not have the Model G1018, skip these instructions.
Jam Nut
Stop Bolt
Figure 34. Model G1018 table stop bolt (only
one side shown).
To set the Model G1018 outfeed table stop bolt:
1.Make sure the outfeed table has been adjust- ed as previously described.
2.Loosen the jam nut on the stop bolt, shown in Figure 34.
3.Turn the stop bolt clockwise until it makes contact with the table base behind the adjust- ment block.
4.Loosen the table lock and move the table down, then move it up until it stops. Make certain the table returns to its correct height by verifying that the outfeed table is even with one of the knife blades at top dead cen- ter.
5.Adjust and check as necessary, then tighten the jam nut on the stop bolt when the table will return to its correct position.
6.Lock the table in place.
To set the Model G1018 infeed table stop bolt:
1.Make sure that the infeed table has been adjusted and that the pointer on the depth indicator scale has been calibrated as previ- ously described.
2.Loosen the jam nut on the stop bolt.
3.Turn the stop bolt clockwise until it makes contact with the table base behind the adjust- ment block.
4.Loosen the table lock and move the table down, then return it to the 0 setting. Make certain the table returns to the 0 point while using the stop bolt.
5.Adjust and check as necessary, then tighten the jam nut on the stop bolt when the table will return to its correct position.
6.Lock the table in place.