Powermatic PJ1696 operating instructions Dust Hood, Start/Stop Switch, Electrical Connection

Page 10

Figure 7

Dust Hood

Mount the dust hood (C, Figure 8), to the left side of the jointer using the seven 1/4-20 x 1/2 screws (D, Figure 8) provided on the machine. Before mounting the dust hood, make sure the hole in the base is covered by the dust chute cover (shown in Figure 5).

It is recommended a dust collection system of appropriate size (at least 800 CFM) be connected to the dust outlet via a 6" diameter hose.

Figure 8

Start/Stop Switch

The arm (E, Figure 9) on which the pushbutton switch is located is shipped in the down position. The screws (F, Figure 9) should be loosened with a 10mm hex wrench and the arm pivoted to upright position. Re-tighten screws.

Figure 9

Electrical Connection

Electrical connections must be made by a qualified electrician. The machine must be properly grounded to help avoid electric shock and possible death.

IMPORTANT: Make sure the electrical characteristics are the same between the motor nameplate and the power source, and make sure the circuit on which the jointer will be used is properly fused and that the wire size is correct.

It is recommended that the jointer when operated at 230 volts, be connected to a dedicated, minimum 40 amp circuit with a 40 amp circuit breaker or time delay fuse. When operated at 460 volts, connect the jointer to a dedicated, minimum 20 amp circuit with 20 amp circuit breaker or time delay fuse. Local codes take precedence over recommendations.

1.Connect wires from the power source to the motor junction box. Refer to diagram inside the motor junction box cover (a similar diagram appears at the back of this manual). The green wire (ground) must be properly grounded.

2.After wiring is complete, turn motor on momentarily to check for proper direction of rotation (cutterhead should rotate toward infeed table). If rotation is in the wrong direction, disconnect machine and switch any two of the hot leads. Reconnect power and confirm proper rotation.

3.Run the machine without cutting for a short time to check that all powered functions are operating properly.

460V Conversion

The Jointer is pre-wired for 230 volt operation. If

460 volt operation is required, proceed as follows:

1.Re-connect the motor leads according to the wiring diagram.

10

Image 10
Contents Inch Jointer Warranty and Service Warranty PeriodTable of Contents Page Page Safety Label Features PJ1696 Jointer Introduction Specifications Fence Installation Installation and AssemblyReceiving the Jointer Dust Hood Start/Stop SwitchElectrical Connection Drive Belt AdjustmentsSetting Outfeed Table Replacing Knife InsertsInfeed Table Adjustment Table Raising Limit BlocksOperating Instruction Fence AdjustmentsHand Placement Edge JointingJointing Short or Thin Work RabbetingJointing Warped Surfaces Direction of GrainTaper Cuts MaintenanceBeveling LubricationBlade Inserts Troubleshooting Replacement PartsParts List Cutterhead Assembly PJ1696 Jointer Index No. Part No Description Size QtyCutterhead Assembly PJ1696 Jointer Parts List Fence Assembly PJ1696 Jointer Fence Assembly PJ1696 Jointer Parts List Stand Assembly PJ1696 Jointer Stand Assembly PJ1696 Jointer Parts List Bed Assembly PJ1696 Jointer Bed Assembly PJ1696 Jointer Parts List Cutterhead Guard Assembly PJ1696 Jointer Cutterhead Guard Assembly PJ1696 Jointer Parts List Infeed Table Assembly PJ1696 Jointer Infeed Table Assembly PJ1696 Jointer Parts List Outfeed Table Assembly PJ1696 Jointer Outfeed Table Assembly PJ1696 Jointer Parts List Motor Assembly PJ1696 Jointer Electrical Connections Preventive Maintenance Page New Sanford Road LaVergne, Tennessee
Related manuals
Manual 4 pages 20.56 Kb