Powermatic 60HH, 60C operating instructions Trouble Probable Cause Remedy

Page 29

Trouble

Probable Cause

Remedy

 

 

 

Machine will not

 

Inspect all motor leads for tightness. Look for

start/restart or

Loose electrical connections.

any signs of electrical arcing which would

repeatedly trips

 

indicate loose connections or circuit overload.

circuit breaker or

 

 

blows fuses.

 

If the on/off switch is suspect, you have two

 

 

 

 

options: Have a qualified electrician test the

 

On/off switch failure.

switch for function, or purchase a new on/off

 

 

switch and establish if that was the problem

 

 

on changeout.

 

 

 

29

Image 29
Contents Part No. M-1610084 WMH Tool GROUP, IncMore Information Warranty and ServiceTable of Contents Page Page 60C Introduction Specifications3HP 3PH 230/460V prewired Features and Terminology 60C and 60HH Jointers Unpacking Contents of the Shipping ContainerTools required for assembly AssemblyAssembling Jointer to Stand Cutterhead GuardRemoving Guard Installing Drive BeltAligning Pulleys Installing Switch Arm Installing Belt Guard and DoorInstalling Dust Chute Hose and clamp not providedKnife Gauge Assembly model 60C only Installing Fence HandwheelElectrical Connections Storing the Push Blocks230V to 460V conversion Grounding InstructionsExtension Cords AdjustmentsInstalling and Adjusting Knives Straight cutterhead only Helical Cutterhead Only Replacing and Rotating Knife InsertsIf table will still not line up Leveling TablesSetting Outfeed Table Adjusting Depth of CutRapid Adjust Fine AdjustFence Movement Examples of incorrect settingsSpring Cutting See Figure Fence StopsDegree stop Degree forward stopStart/Stop Operating ControlsBasic Jointer Operation Hand PlacementJointing Short or Thin Work Direction of GrainBeveling Jointing Warped SurfacesEdge Jointing Taper Cuts Skewing Shear CuttingRabbeting Maintenance Sharpening Knives model 60C only Cutterhead MaintenanceTable Removal Probable Cause Remedy Troubleshooting Mechanical and Electrical ProblemsTrouble Trouble Probable Cause Remedy Helical cutterhead Rotate nicked Troubleshooting Operating ProblemsStraight cutterhead Replace nicked Index No. Part No Description Size Qty Replacement PartsParts List Base Assembly 60C and 60HH TS-081B012 Base Assembly 60C and 60HH Parts List Fence Assembly 60C and 60HH Fence Assembly 60C and 60HH Parts List Straight Cutterhead Assembly 60C only Parts List Helical Cutterhead Assembly 60HH only 60B-415MDC Parts List Stand Assembly 60C and 60HH60C-439 Electrical Connections Single Phase, 230 Volt Electrical Connections 3 Phase, 230 Volt Electrical Connections 3 Phase, 460 Volt Page Vantage Drive Elgin, Illinois Phone
Related manuals
Manual 44 pages 25.26 Kb