Makita TD0101F specifications Hammer case Complete 1R223 Flat portions, Assembling

Page 4

P 4/ 14

Repair

[3]DISASSEMBLY/ASSEMBLY

[3]-1. Hammer Case Complete

DISASSEMBLING

(2)The removed Hammer case section is disassembled as illustrated in Fig. 4.

Fig. 4

Hold the flat portion of Hammer case complete in vise with 1R041.

Hammer case

 

complete

1R223

 

 

flat portions

Attach 134847-1 and 1R224 to 1R223, and fit 134847-1 to the hex portion of Bearing box.

Then turn 1R223 clockwise.

Hammer case complete can be disassembled as illustrated

below.

1R224 Hammer case

complete

Vise

134847-1 Bearing box

1R041

Hammer

Internal gear 43

Bearing box

ASSEMBLING

(1)Use 134847-1 as a supporting jig for Bearing box and assemble Hammer case complete as illustrated in Fig. 5.

Fig. 5

Set Bearing box to 134847-1 held with vise. And then insert the ring portion of Internal gear 43 into Bearing box.

Assemble Hammer section while engaging Spur gear 17 with Internal gear 43.

Assemble Hammer case complete to Bearing box while aligning the hollows of Bearing box to the projections of Internal gear 43. Then turn Hammer case complete counterclockwise by hand and tighten as firm as possible.

Internal

ring portion

 

hollow (6 pcs.)

gear 43

 

 

 

 

Hammer

 

Bearing box

 

section

 

 

 

 

 

 

 

projections (6pcs.)

 

Bearing

Spur gear 17

Hammer case

 

box

 

complete

 

 

Internal

Bearing

 

 

box

 

 

gear 43

 

 

 

134847-1

 

 

 

Internal gear 43

Image 4
Contents Specification Optional accessoriesTD0101, TD0101F TD0101/ TD0101FNecessary Repairing Tools RepairHammer Case Section DisassemblingHammer case Complete 1R223 Flat portions AssemblingFastening torque is 25 30 N.m Hammer Case CompleteHook Anvil and Bit holding Mechanism Pay attention not to lose Steel ballHammer Section Spindle sectionDISASSEMBLY/ASSEMBLY Circuit diagram TD0101 220V to 110V to Housing set Left side Right sideHousing set Left side Right side Brush holder FieldWiring diagram TD0101Fig. D-3 LEDWiring of Lead wire brown or black of Power supply cord 220-240V area except Argentine, Chile etcFig. D-5 TD0101F 110V for UK 110 127V area