Bryant 549B, 542J manual 548F060 5 Tons HIGH-STATIC Motor Belt Drive

Page 35

PERFORMANCE DATA (cont)

FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (cont)

548F060 (5 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)*

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1500

808

0.42

429

914

0.56

572

1001

0.69

705

1084

0.85

869

1168

1.01

1032

1600

846

0.49

501

950

0.64

645

1034

0.78

797

1111

0.94

961

1194

1.11

1134

1700

884

0.57

582

983

0.72

736

1068

0.88

899

1145

1.03

1053

1218

1.21

1237

1800

924

0.66

674

1018

0.82

838

1105

0.98

1001

1179

1.13

1155

1246

1.32

1349

1900

965

0.76

777

1057

0.92

940

1143

1.10

1124

1212

1.26

1288

1280

1.43

1461

2000

1008

0.87

889

1096

1.04

1063

1177

1.22

1247

1247

1.40

1431

1300

1.57

1604

2100

1051

0.99

1012

1136

1.17

1196

1210

1.35

1380

1284

1.54

1574

1347

1.72

1758

2200

1095

1.12

1145

1173

1.30

1328

1245

1.49

1523

1322

1.70

1737

1380

1.89

1931

2300

1140

1.26

1288

1210

1.47

1502

1284

1.65

1686

1356

1.80

1901

1418

2.07

2115

2400

1185

1.41

1441

1249

1.61

1645

1323

1.80

1860

1389

2.03

2074

1456

2.26

2310

2500

1231

1.57

1604

1289

1.78

1819

1363

2.00

2044

1424

2.22

2269

1500

2.45

2504

 

 

 

 

 

 

 

 

 

 

 

548F060 (5 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)* (cont)

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1500

1199

1.19

1216

1126

1.46

1492

1250

1.69

1757

1301

1.91

1944

1349

2.12

2164

1600

1263

1.28

1308

1275

1.49

1523

1299

1.78

1800

1352

2.01

2047

1401

2.23

2280

1700

1295

1.39

1420

1351

1.58

1615

1352

1.80

1850

1407

2.03

2070

1459

2.26

2305

1800

1319

1.52

1553

1389

1.71

1747

1435

1.91

1952

1494

2.15

2197

1548

2.40

2446

1900

1343

1.64

1676

1415

1.80

1891

1478

2.05

2095

1538

2.31

2358

1594

2.57

2625

2000

1374

1.77

1809

1438

1.99

2034

1505

2.21

2258

1566

2.49

2542

1624

2.77

2830

2100

1409

1.91

1952

1465

2.14

2167

1533

2.45

2501

1596

2.77

2821

1654

3.08

3141

2200

1442

2.08

2126

1498

2.30

2350

1568

2.64

2688

1632

2.97

3031

1691

3.31

3375

2300

1475

2.26

2310

1554

2.64

2698

1627

3.03

3091

1693

3.42

3486

1755

3.81

3881

2400

1565

2.47

2524

1649

2.89

2948

1726

3.31

3379

2500

1596

2.95

3010

1682

3.45

3522

1760

3.96

4036

 

LEGEND

NOTES:

Bhp

Brake Horsepower Input to Fan

1.

 

Boldface indicates field-supplied drive is required.

Watts

Input Watts to Motor

2.

 

 

indicates field-supplied motor and drive are required.

*Motor drive range: 1300 to 1685 rpm. All other rpms require field-supplied drive.

3.

Maximum continuous bhp is 2.9 and the maximum continuous watts are 2562.

 

 

 

 

Refer to page 51 for general Fan Performance notes.

548F072 (6 TONS)* — STANDARD MOTOR (BELT DRIVE)

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

0.1

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1800

852

0.55

562

905

 

0.62

615

1002

0.78

739

1084

0.93

859

1163

1.10

998

1900

894

0.64

630

945

 

0.72

692

1037

0.88

818

1119

1.04

948

1194

1.21

1089

2000

936

0.74

708

984

 

0.82

771

1072

0.98

899

1154

1.16

1047

1226

1.33

1190

2100

978

0.85

795

1024

 

0.93

859

1108

1.10

998

1190

1.29

1156

1259

1.47

1310

2200

1021

0.97

891

1064

 

1.05

956

1145

1.22

1097

1225

1.43

1275

1294

1.62

1439

2300

1064

1.10

998

1104

 

1.18

1064

1183

1.36

1216

1260

1.57

1396

1330

1.78

1578

2400

1107

1.24

1114

1145

 

1.32

1182

1222

1.52

1353

1296

1.73

1534

1365

1.94

1718

2500

1150

1.39

1241

1186

 

1.48

1318

1262

1.68

1491

1331

1.89

1674

1400

2.12

1875

2600

1193

1.56

1387

1228

 

1.65

1465

1301

1.86

1648

1367

2.07

1831

1435

2.31

2041

2700

1237

1.74

1543

1269

 

1.83

1621

1341

2.05

1814

1404

2.26

1997

1471

2.51

2214

2800

1280

1.94

1718

1311

 

2.03

1796

1381

2.25

1989

1442

2.47

2180

1506

2.72

2394

2900

1324

2.15

1901

1354

 

2.24

1980

1420

2.47

2180

1481

2.69

2369

1542

2.94

2579

3000

1368

2.37

2093

1396

 

2.46

2171

1460

2.69

2369

1521

2.93

2571

 

 

 

 

 

 

 

 

 

 

 

 

548F072 (6 TONS)* — STANDARD MOTOR (BELT DRIVE) (cont)

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

1.0

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

 

 

1800

1235

1.29

1156

1303

 

1.48

1318

1371

1.69

1499

1433

1.90

1638

 

 

 

1900

1266

1.40

1250

1330

 

1.59

1413

1396

1.81

1604

1460

2.03

1796

 

 

 

2000

1297

1.53

1361

1362

 

1.73

1534

1422

1.94

1718

1485

2.16

1910

 

 

 

2100

1327

1.66

1473

1393

 

1.87

1656

1452

2.08

1840

1510

2.31

2041

 

 

 

2200

1359

1.81

1604

1423

 

2.02

1779

1483

2.24

1980

1538

2.46

2171

 

 

 

2300

1392

1.97

1744

1454

 

2.18

1927

1515

2.41

2128

1569

2.64

2326

 

 

 

2400

1426

2.15

1901

1485

 

2.36

2084

1544

2.59

2283

1601

2.84

2459

 

 

 

2500

1461

2.34

2067

1518

 

2.55

2249

1575

2.78

2445

 

 

 

2600

1497

2.54

2240

1552

 

2.76

2428

 

 

 

2700

1532

2.75

2420

 

 

 

 

2800

 

 

 

 

2900

 

 

 

 

3000

 

 

 

 

 

LEGEND

NOTES:

Bhp

Brake Horsepower Input to Fan

1.

 

Boldface indicates field-supplied drive is required.

Watts

Input Watts to Motor

2.

 

 

indicates field-supplied motor and drive are required.

*Motor drive range: 1070 to 1460 rpm. All other rpms require field-supplied drive.

3.

Maximum usable watts input is 2120 and maximum continuous bhp is 2.40.

 

 

 

 

Refer to page 51 for general Fan Performance notes.

548F036-120

35

Image 35
Contents 548F036-072 548F090-120 549B036-072 549B090-120 FEATURES/BENEFITS542J150,180 Table of Contents INDOOR-AIR Quality Begins with Bryant Rooftops Service OptionsIntegrated ECONOMI$ERS and Outdoor AIR Option ACCESSORY† Options and AccessoriesEmergency Heat Control Package Options and AccessoriesBarometric RELIEF/POWER Exhaust LOW Ambient ControlsECONOMI$ER Microprocessor Controller DURA-SHIELDOUTDOOR Coil OptionsOutdoor Coil Protection Applications Electric HeatersGlycol Coil 150,180 only Convenience OutletControl BOX Hinged Panel Option Hail GuardBryant Commercial Programmable Thermostat Compressor Hinged Panel OptionOptions and Accessories Cooling, Units With EconoMi$er 548F036-072 and 549B036 ControlsSequence of Operation 542J150,180 ControlsControls Operating Modes Typical Smoke Control/Fire Shutdown Wiring 542J150,180Application Data Concentric Duct Details 542J150,180 Application DataConcentric Duct Distribution 542J150,180 Vertical Discharge Ducting 548F036-120 and 549B036-120 Typical Piping and WiringHorizontal Discharge Ducting 548F036-120 and 549B036-120 Typical Piping and Wiring ARI* Capacity Ratings Model Number Nomenclature 548F UnitsODS Model Number 548F036-072 Physical Data548F090-120 Physical Data072-548F036 Base Unit Dimensions CRRFCURB002A00 Accessory DimensionsConnector ALT GAS Power Control PKG. Accy Drain Hole Roof Curb Unit Size Accessory CRRFCURB001A00Accessory Dimensions III Select Electric Heat Selection Procedure with 548F048 ExampleDetermine Cooling and Heating Loads AT Design Conditions II Select Unit Based on Required Cooling CapacityEntering AIR DRY-BULB Temp F Performance DataCooling Capacities SHCEntering AIR DRY-BULB Temp F Bypass Performance DataCooling Capacities Under Air Temperature Entering Outdoor Coil FInstantaneous and Integrated Heating Ratings 4100/0.18 4700/0.21Instantaneous and Integrated Heating Ratings 2600 Cap 1800 Cap2400 Cap 3000 Cap4000 Cap CfmStandard Air 2400 Cap 3600 Cap548F036 3 Tons Alternate Motor Belt Drive FAN Performance Vertical Discharge Units548F036 3 Tons Standard Motor Direct Drive ESP548F048 4 Tons Alternate Motor Belt Drive FAN Performance Vertical Discharge Units548F060 5 Tons Alternate Motor Belt Drive 548F060 5 Tons Standard Motor Direct DriveESP 548F060 5 Tons HIGH-STATIC Motor Belt Drive 548F072 6 Tons HIGH-STATIC Motor Belt Drive 534 607 Rpm Bhp Watts511 539 518 562548F090 71/2 Tons HIGH-STATIC Motor Belt Drive 548F102 8 TONS* Standard Motor Belt Drive 548F102 81/2 Tons HIGH-STATIC Motor Belt Drive 973 2782 548F120 10 TonsRpm Bhp 963 2651Cfm Rpm Bhp Watts FAN Performance Horizontal Discharge UnitsAirflow Low Speed High Speed Cfm 208 230, 460, 575 548F048 4 Tons Alternate Motor Belt Drive FAN Performance Horizontal Discharge Units765 460 821 521 658 276 722 337 840 470693 327 754 388 867 531 729 388 787 450 895 593548F072 6 Tons Standard Motor Belt Drive 548F060 5 Tons HIGH-STATIC Motor Belt Drive1114 Rpm Bhp Watts 1800 942 700 1047 835 1139 9561031 1276 1900 982 779 1084 932 1160 10062500 494 554 581 723 Rpm Bhp Watts 2250 465 473 554 6302300 471 487 559 646 2400 482 524 569 6842500 542 648 619 835 686 1022 748 1258 806 Rpm Bhp Watts 2250 507 547 586 700 658 891 722 1097 7832300 513 562 592 723 663 916 727 1131 786 2400 528 600 606 779 674 965 738 1199 795548F102 81/2 Tons Standard Motor Belt Drive 3200 652 1089 718 1327 778 1595 831 1849 Rpm Bhp Watts 2550 669 627 867 692 1056 754 1292 8122900 604 867 676 1089 737 1318 794 1560 848 3100 636 1006 704 1241 764 1499 818 1744General Notes for FAN Performance Tables Component CFM ACCESSORY/FIOP Static PRESSURE* in. wg 548F036-072ACCESSORY/FIOP Static PRESSURE* in. wg 548F090-120 FAN RPM AT Motor Pulley SETTINGS* 548F036-120Mocp Size Optional Power ExhaustEconoMi$er Barometric Relief Damper Characteristics Power RequirementsDistribution Electric Heating CapacitiesMultiplication Factors Heater Rating090 INDOOR-FAN Motor Performance 548F UnitsUnit INDOOR-FAN Maximum Acceptable Motor Operating Watts AMP Draw Efficiency %Units Without Electrical Convenience Outlet Electrical DataUnits Without Electrical Convenience Outlet Electrical DataTons Voltage Compressor Electric Heat Power Supply DisconnectNominal IFM Range OFM IFM SIZE†81/2 Tons Units with Electrical Convenience Outlet Units with Electrical Convenience Outlet 40.4 45†† 195/195 13.6/15.6 57.4 59.9 60†† 208/211 Voltage Compressor Electric Power Supply Disconnect Unbalanced 3-Phase Supply Voltage SW4 Typical Wiring SchematicOutdoor-Fan Motor Typical Wiring Schematic549B072-120 Model Number Nomenclature549B E X 090 000 AA 549B036-060Base Unit 549B 549B036-072549B090,120 Base Unit Dimensions 549B036-120 549B090,120 ′-0 ″ ′-2 ″549B036-072 ″ 19 NPT 827 583 44.5 12.7 NPT Enter Cooling Capacities table at outdoor entering temper Selection Procedure with 549B048 ExampleII Select Unit Based on Required Cooling CapacityFactor SHCEntering AIR DRY-BULB Temp F Bypass 2250/0.12 3000/0.15 3750/0.18 Entering Air 549B072 6 Tons Temp F1800/0.06 2100/0.066 2400/0.071 3000/0.088 Entering Air 549B090 71/2 Tons Temp F549B048 4 Tons 549B036 3 Tons900 Cap 2100 Cap 549B060 5 Tons549B072 6 Tons 549B120 10 Tons Temperature Air Entering Outdoor Coil F db at 70% rh549B090 71/2 Tons 746 806 867 929 964 1200 Rpm Bhp 900673 736 805 865 911 1000 709 782 835 900 937 1100549B072 6 Tons Standard Motor Belt Drive 549B060 5 Tons Standard Motor Belt Drive549B090 71/2 Tons Standard Motor Belt Drive 549B120 10 Tons Standard Motor Belt Drive 710 780 840 889 938 1300 584 656 734 818 875 1000627 738 800 848 895 1100 670 758 812 863 914 1200Airflow External Static Pressure in. wg Cfm Rpm Bhp 1500 1108 1187 1202 10792100 1252 1320 1388 1448 1372645 708 Rpm Bhp 2250630 695 635 699625 691 744 796 595 657 716 770605 667 725 779 615 679 734 787549B 036 ACCESSORY/FIOP Static PRESSURE* in. wg 549B036-072ACCESSORY/FIOP Static PRESSURE* in. wg 549B090,120 FAN RPM AT Motor Pulley SETTINGS* 549B036-120INDOOR-FAN Motor Data 549B036-120 Electric Heating Capacities Outdoor Sound Power Total UnitFLA MCA Mocp LRA Nominal Voltage Electric Power Minimum Unit Compressor OFMDisconnect Voltage Range Heat Supply RLA LRARLA LRA FLA Nominal Voltage Electric Power Minimum Unit CompressorIFM Disconnect Voltage Range Heat Supply Ph-Hz Min Max30.4 106/106 43.0 247/247 10.4 21.7 25.0 70.1 74.3 269/272 Typical Wiring Schematic RVS MustRating HFG. PT. no Trip Potter & Brunfield AmpsPart 2 Products Guide Specifications 548F and 549B036-120 UnitsPart 1 General Guide Specifications 548F and 549B036-120 Units Guide Specifications 548F and 549B036-120 Units 100 542J E X 150 000 AB H B Model Number Nomenclature 542J150,180 UnitsCooling HEATING-HIGH Temp HEATING-LOW Temp Sound Unit Weight Distribution and Center of GravityUnit Weight Weight of Corner Dimensions 542J150,180 UnitsSTD ALT Unit 542JSTD ALT542J 150 1895 860 180 2205 1000 Unit Maximum Shipping WeightUnit Dimensions Unit Weight of CornerCRRFCURB012A00 DIMENSIONS* degrees and inchesPKG NO. REF Curb Description Height CRRFCURB010A00 CRRFCURB011A00Height Horizontal Adapter Installation 542J150,180Accessory Curb Description Convenience Outlet 542J150,180Non-Fused Disconnect 542J150,180 Power Exhaust 542J150,180Capacity TC of 180,800 Btuh, a sensible heat capacity Selection Procedure with 542J180 Example542J180 542J150 Temp F Air Entering Indoor Coil Cfm/BFCFM Integrated Heating Capacities5625 General Notes for FAN Performance Tables ACCESSORY/FIOP Unit Size Unit Voltage CFM ACCESSORY/FIOP Static PRESSURE* in. wg 542J150,180FAN RPM AT Motor Pulley SETTINGS* 542J150,180 Fan Performance Using Accessory Power ExhaustGlycol Coil Ratings Electric Heating Capacities 542J150,180Glycol Coil Data INDOOR-FAN Motor Performance 542J150,180 542J180, 460-3-60 Shown CAP BKR W/ATLOR LPSOptional Non-Fused Disconnect 542J150,180 Part 2 Products Guide Specifications 542J150,180 UnitsPart 1 General Guide Specifications 542J150,180 Units 120 121 95,96 Index
Related manuals
Manual 4 pages 35.17 Kb

549B, 548F, 542J specifications

Bryant 542J is a high-efficiency gas furnace that stands out for its reliability and advanced heating technologies. Designed to deliver consistent warmth and comfort in residential settings, it combines innovative engineering with energy-efficient features.

One of the key characteristics of the Bryant 542J is its two-stage heating capability. This means that the furnace can adjust its heat output according to the heating demands of your home. During milder weather, it operates at a lower stage, consuming less energy while still maintaining a comfortable environment. When the temperatures drop, the furnace shifts to its higher capacity, providing the necessary warmth efficiently. This not only enhances comfort but also contributes to lower energy bills.

In addition to its two-stage operation, the Bryant 542J also incorporates a variable-speed blower motor. This technology allows the furnace to adjust the airflow depending on the heating requirements, ensuring an even distribution of warm air throughout the home. The variable-speed blower also operates more quietly than conventional fixed-speed motors, creating a serene indoor environment.

Energy efficiency is a hallmark of the Bryant 542J, boasting an Annual Fuel Utilization Efficiency (AFUE) rating of up to 96.5%. This impressive rating means that a significant portion of the energy consumed is effectively converted into usable heat, resulting in substantial savings on heating costs over time. Furthermore, the furnace is equipped with a sealed combustion system that draws air from outside the home, minimizing energy waste and improving indoor air quality.

Diagnostic features are another highlight of the Bryant 542J, which come equipped with SmartEvap technology. This allows the unit to self-diagnose potential issues, providing homeowners with peace of mind and simplifying maintenance procedures.

Durability is also a key feature of the Bryant 542J. It is constructed with high-quality materials designed to withstand harsh winter conditions, ensuring a long lifespan and reliable performance. Its compact design also allows for flexible installation, making it suitable for various residential layouts.

In summary, the Bryant 542J is more than just a gas furnace; it is a sophisticated heating solution that combines efficiency, comfort, and reliability. With features such as two-stage heating, a variable-speed blower, high AFUE ratings, and advanced diagnostics, it is an excellent choice for homeowners seeking an efficient and effective heating system.