Bryant FAN Performance Horizontal Discharge Units, 548F048 4 Tons Alternate Motor Belt Drive

Page 43

PERFORMANCE DATA (cont)

FAN PERFORMANCE — HORIZONTAL DISCHARGE UNITS (cont)

548F048 (4 TONS) — STANDARD MOTOR (DIRECT DRIVE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

Low Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Speed

 

 

 

 

 

 

 

 

 

 

 

208 v

 

 

 

 

 

 

230, 460, 575 v

 

 

 

 

 

 

 

208 v

 

 

 

 

 

230, 460, 575 v

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ESP

Bhp

 

 

Watts

 

 

ESP

 

 

Bhp

Watts

 

 

ESP

 

 

 

Bhp

 

Watts

ESP

 

 

Bhp

 

 

Watts

1200

 

 

0.93

 

0.41

 

458

 

 

 

0.97

 

 

0.45

506

 

 

1.04

 

 

0.51

 

572

 

1.09

 

 

0.56

 

 

632

1300

 

 

0.86

 

0.42

 

471

 

 

 

0.90

 

 

0.46

521

 

 

0.96

 

 

0.52

 

589

 

1.02

 

 

0.58

 

 

651

1400

 

 

0.78

 

0.45

 

503

 

 

 

0.84

 

 

0.49

556

 

 

0.90

 

 

0.54

 

616

 

0.96

 

 

0.60

 

 

681

1500

 

 

0.73

 

0.47

 

536

 

 

 

0.76

 

 

0.52

593

 

 

0.83

 

 

0.56

 

631

 

0.89

 

 

0.62

 

 

698

1600

 

 

0.67

 

0.49

 

557

 

 

 

0.70

 

 

0.54

616

 

 

0.75

 

 

0.58

 

654

 

0.82

 

 

0.64

 

 

723

1700

 

 

0.60

 

0.52

 

584

 

 

 

0.63

 

 

0.57

646

 

 

0.67

 

 

0.60

 

678

 

0.74

 

 

0.66

 

 

750

1800

 

 

0.51

 

0.54

 

610

 

 

 

0.54

 

 

0.60

674

 

 

0.62

 

 

0.62

 

698

 

0.69

 

 

0.68

 

 

772

1900

 

 

0.40

 

0.56

 

629

 

 

 

0.45

 

 

0.62

696

 

 

0.54

 

 

0.64

 

720

 

0.62

 

 

0.70

 

 

796

2000

 

 

0.32

 

0.58

 

661

 

 

 

0.33

 

 

0.65

731

 

 

0.47

 

 

0.66

 

744

 

0.54

 

 

0.73

 

 

823

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 51 for general Fan Performance notes.

 

 

 

 

 

 

Bhp

Brake Horsepower Input to Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ESP

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Watts — Input Watts to Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

548F048 (4 TONS) — ALTERNATE MOTOR (BELT DRIVE)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

 

 

 

0.2

 

 

 

 

0.3

 

 

 

0.4

 

 

 

 

0.6

 

 

 

0.7

 

 

 

 

0.8

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Watts

Rpm

 

Bhp

 

Watts

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

Rpm

Bhp

Watts

1200

514

 

0.15

 

158

590

 

0.20

 

210

657

0.25

263

723

 

0.30

 

315

828

 

0.42

441

876

0.49

 

510

924

0.55

578

1300

545

 

0.18

 

189

615

 

0.23

 

242

680

0.29

305

744

 

0.35

 

368

849

 

0.47

494

895

0.54

 

562

940

0.60

630

1400

577

 

0.21

 

221

642

 

0.27

 

284

704

0.33

347

766

 

0.39

 

410

870

 

0.52

546

915

0.59

 

620

959

0.66

693

1500

609

 

0.26

 

273

670

 

0.31

 

326

729

0.38

394

788

 

0.44

 

462

892

 

0.58

609

936

0.65

 

683

980

0.72

757

1600

642

 

0.30

 

315

699

 

0.36

 

378

755

0.43

447

811

 

0.49

 

515

913

 

0.64

672

957

0.72

 

751

1001

0.79

830

1700

675

 

0.36

 

378

728

 

0.42

 

441

782

0.49

510

836

 

0.55

 

578

935

 

0.71

746

979

0.79

 

825

1023

0.86

904

1800

709

 

0.41

 

431

759

 

0.48

 

504

810

0.55

578

860

 

0.62

 

651

957

 

0.78

820

1001

0.86

 

904

1044

0.94

988

1900

743

 

0.48

 

504

790

 

0.55

 

578

838

0.62

651

886

 

0.69

 

725

980

 

0.86

904

1023

0.95

 

993

1066

1.03

1082

2000

778

 

0.55

 

578

836

 

0.62

 

651

875

0.70

730

913

 

0.77

 

809

1004

 

0.94

988

1046

1.03

 

1082

1088

1.12

1177

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

548F048 (4 TONS) — ALTERNATE MOTOR (BELT DRIVE)* (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

 

 

 

1.1

 

 

 

 

1.2

 

 

 

1.4

 

 

 

 

1.6

 

 

 

1.8

 

 

 

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Watts

Rpm

 

Bhp

 

Watts

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

 

Bhp

 

Watts

Rpm

Bhp

 

Watts

 

 

 

 

1200

999

 

0.66

 

674

1018

 

0.67

 

685

1036

0.68

695

1073

 

0.71

 

756

1109

 

0.75

794

1138

0.79

 

851

 

 

 

 

1300

1025

 

0.74

 

756

1058

 

0.79

 

807

1090

0.84

858

1121

 

0.87

 

832

1159

 

0.90

918

1193

0.95

 

976

 

 

 

 

1400

1042

 

0.81

 

828

1080

 

0.88

 

899

1118

0.95

971

1175

 

1.06

 

1014

1206

 

1.09

1042

1244

1.12

 

1138

 

 

 

 

1500

1060

 

0.88

 

899

1098

 

0.96

 

981

1136

1.04

1063

1205

 

1.19

 

1138

1258

 

1.30

1243

1289

1.34

 

1282

 

 

 

 

1600

1080

 

0.95

 

971

1117

 

1.04

 

1058

1153

1.12

1140

1224

 

1.29

 

1234

1287

 

1.45

1387

1337

1.56

 

1492

 

 

 

 

1700

1101

 

1.03

 

1053

1137

 

1.12

 

1139

1172

1.20

1226

1241

 

1.38

 

1320

1307

 

1.56

1492

1366

1.73

 

1655

 

 

 

 

1800

1122

 

1.11

 

1134

1157

 

1.20

 

1226

1192

1.29

1318

1258

 

1.48

 

1415

1323

 

1.67

1597

1385

1.86

 

1779

 

 

 

 

1900

1143

 

1.21

 

1237

1179

 

1.30

 

1328

1214

1.39

1420

1279

 

1.58

 

1511

1341

 

1.78

1702

1402

1.98

 

1894

 

 

 

 

2000

1165

 

1.31

 

1339

1200

 

1.40

 

1431

1235

1.49

1523

1300

 

1.69

 

1616

1361

 

1.90

1817

1419

2.10

 

2008

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bhp

Brake Horsepower Input to Fan

 

 

 

 

 

 

 

 

 

 

 

1. Boldface indicates field-supplied drive is required.

 

 

 

 

 

 

Watts

Input Watts to Motor

 

 

 

 

 

 

 

 

 

 

 

 

2.

 

indicates field-supplied motor and drive are required.

 

 

 

 

*Motor drive range: 835 to 1185 rpm. All other rpms require field-supplied drive.

 

 

 

3.

Maximum usable watts input is 1000 and maximum continuous bhp is 1.00.

 

Refer to page 51 for general Fan Performance notes.

548F048 (4 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

0.2

 

 

 

 

 

0.4

 

 

 

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1200

 

641

 

0.23

 

242

 

761

 

0.34

 

357

 

859

 

0.46

483

943

0.58

609

1030

0.70

695

1300

 

673

 

0.28

 

294

 

788

 

0.39

 

410

 

887

 

0.52

546

968

0.65

683

1044

0.77

736

1400

 

705

 

0.33

 

347

 

817

 

0.45

 

473

 

914

 

0.59

620

996

0.72

757

1069

0.86

838

1500

 

738

 

0.38

 

399

 

847

 

0.51

 

536

 

940

 

0.65

683

1024

0.81

851

1095

0.95

930

1600

 

772

 

0.44

 

462

 

877

 

0.58

 

609

 

967

 

0.73

767

1051

0.89

935

1123

1.05

1073

1700

 

806

 

0.51

 

536

 

908

 

0.66

 

693

 

997

 

0.81

851

1077

1.01

1030

1151

1.15

1185

1800

 

841

 

0.59

 

620

 

939

 

0.75

 

788

 

1026

 

0.91

956

1104

1.07

1124

1178

1.26

1318

1900

 

876

 

0.68

 

714

 

971

 

0.84

 

883

 

1056

 

1.01

1061

1132

1.18

1240

1204

1.37

1502

2000

 

912

 

0.77

 

809

 

1004

 

0.94

 

988

 

1087

 

1.12

1177

1162

1.30

1366

1231

1.48

1604

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

548F048 (4 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)* (cont)

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

1.2

 

 

 

 

 

1.4

 

 

 

 

 

1.6

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Watts

 

Rpm

 

Bhp

 

Watts

 

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1200

 

1106

 

0.87

 

889

 

1134

 

0.98

 

998

 

1189

 

1.12

1138

1245

1.21

1358

1292

1.35

1345

1300

 

1128

 

0.91

 

930

 

1183

 

1.10

 

1052

 

1226

 

1.23

1215

1297

1.35

1406

1346

1.51

1500

1400

 

1139

 

1.01

 

1012

 

1218

 

1.14

 

1090

 

1286

 

1.34

1282

1320

1.48

1463

1370

1.65

1645

1500

 

1162

 

1.09

 

1114

 

1228

 

1.24

 

1186

 

1303

 

1.40

1339

1343

1.60

1530

1393

1.79

1778

1600

 

1185

 

1.20

 

1226

 

1250

 

1.35

 

1291

 

1319

 

1.51

1444

1382

1.68

1607

1434

1.88

1867

1700

 

1215

 

1.31

 

1339

 

1276

 

1.48

 

1415

 

1334

 

1.64

1569

1398

1.80

1722

1451

2.01

2001

1800

 

1243

 

1.43

 

1461

 

1303

 

1.61

 

1540

 

1359

 

1.78

1702

1418

1.95

1865

1471

2.18

2167

1900

 

1271

 

1.56

 

1594

 

1330

 

1.74

 

1664

 

1386

 

1.93

1846

1439

2.11

2018

1493

2.36

2345

2000

 

1298

 

1.69

 

1727

 

1358

 

1.89

 

1808

 

1413

 

2.08

1989

1466

2.27

2171

 

LEGEND

Refer to page 51 for general Fan Performance notes.

Bhp

Brake Horsepower Input to Fan

NOTES:

Watts

Input Watts to Motor

1.

Boldface indicates field-supplied drive is required.

*Motor drive range: 1075 to 1455 rpm. All other rpms require field-supplied drive.

2.

Maximum continuous bhp is 2.4 and the maximum continuous watts are 2120.

 

 

548F036-120

43

Image 43
Contents 542J150,180 FEATURES/BENEFITS548F036-072 548F090-120 549B036-072 549B090-120 Table of Contents Integrated ECONOMI$ERS and Outdoor AIR Service OptionsINDOOR-AIR Quality Begins with Bryant Rooftops Option ACCESSORY† Options and AccessoriesEmergency Heat Control Package Options and AccessoriesBarometric RELIEF/POWER Exhaust LOW Ambient ControlsECONOMI$ER Microprocessor Controller DURA-SHIELDOUTDOOR Coil OptionsOutdoor Coil Protection Applications Electric HeatersGlycol Coil 150,180 only Convenience OutletControl BOX Hinged Panel Option Hail GuardBryant Commercial Programmable Thermostat Compressor Hinged Panel OptionOptions and Accessories Cooling, Units With EconoMi$er 548F036-072 and 549B036 ControlsSequence of Operation 542J150,180 ControlsControls Operating Modes Typical Smoke Control/Fire Shutdown Wiring 542J150,180Application Data Concentric Duct Distribution 542J150,180 Application DataConcentric Duct Details 542J150,180 Horizontal Discharge Ducting 548F036-120 and 549B036-120 Typical Piping and WiringVertical Discharge Ducting 548F036-120 and 549B036-120 Typical Piping and Wiring ODS Model Number Model Number Nomenclature 548F UnitsARI* Capacity Ratings 548F036-072 Physical Data548F090-120 Physical Data072-548F036 Base Unit Dimensions CRRFCURB002A00 Accessory DimensionsConnector ALT GAS Power Control PKG. Accy Drain Hole Roof Curb Unit Size Accessory CRRFCURB001A00Accessory Dimensions III Select Electric Heat Selection Procedure with 548F048 ExampleDetermine Cooling and Heating Loads AT Design Conditions II Select Unit Based on Required Cooling CapacityEntering AIR DRY-BULB Temp F Performance DataCooling Capacities SHCCooling Capacities Performance DataEntering AIR DRY-BULB Temp F Bypass Under Air Temperature Entering Outdoor Coil FInstantaneous and Integrated Heating Ratings 4100/0.18 4700/0.21Instantaneous and Integrated Heating Ratings 2600 Cap 1800 Cap2400 Cap 3000 Cap4000 Cap CfmStandard Air 2400 Cap 3600 Cap548F036 3 Tons Alternate Motor Belt Drive FAN Performance Vertical Discharge Units548F036 3 Tons Standard Motor Direct Drive ESP548F048 4 Tons Alternate Motor Belt Drive FAN Performance Vertical Discharge UnitsESP 548F060 5 Tons Standard Motor Direct Drive548F060 5 Tons Alternate Motor Belt Drive 548F060 5 Tons HIGH-STATIC Motor Belt Drive 548F072 6 Tons HIGH-STATIC Motor Belt Drive 534 607 Rpm Bhp Watts511 539 518 562548F090 71/2 Tons HIGH-STATIC Motor Belt Drive 548F102 8 TONS* Standard Motor Belt Drive 548F102 81/2 Tons HIGH-STATIC Motor Belt Drive 973 2782 548F120 10 TonsRpm Bhp 963 2651Airflow Low Speed High Speed Cfm 208 230, 460, 575 FAN Performance Horizontal Discharge UnitsCfm Rpm Bhp Watts 548F048 4 Tons Alternate Motor Belt Drive FAN Performance Horizontal Discharge Units765 460 821 521 658 276 722 337 840 470693 327 754 388 867 531 729 388 787 450 895 593548F072 6 Tons Standard Motor Belt Drive 548F060 5 Tons HIGH-STATIC Motor Belt Drive1114 Rpm Bhp Watts 1800 942 700 1047 835 1139 9561031 1276 1900 982 779 1084 932 1160 10062500 494 554 581 723 Rpm Bhp Watts 2250 465 473 554 6302300 471 487 559 646 2400 482 524 569 6842500 542 648 619 835 686 1022 748 1258 806 Rpm Bhp Watts 2250 507 547 586 700 658 891 722 1097 7832300 513 562 592 723 663 916 727 1131 786 2400 528 600 606 779 674 965 738 1199 795548F102 81/2 Tons Standard Motor Belt Drive 3200 652 1089 718 1327 778 1595 831 1849 Rpm Bhp Watts 2550 669 627 867 692 1056 754 1292 8122900 604 867 676 1089 737 1318 794 1560 848 3100 636 1006 704 1241 764 1499 818 1744General Notes for FAN Performance Tables Component CFM ACCESSORY/FIOP Static PRESSURE* in. wg 548F036-072ACCESSORY/FIOP Static PRESSURE* in. wg 548F090-120 FAN RPM AT Motor Pulley SETTINGS* 548F036-120Mocp Size Optional Power ExhaustEconoMi$er Barometric Relief Damper Characteristics Power RequirementsDistribution Electric Heating CapacitiesMultiplication Factors Heater Rating090 INDOOR-FAN Motor Performance 548F UnitsUnit INDOOR-FAN Maximum Acceptable Motor Operating Watts AMP Draw Efficiency %Units Without Electrical Convenience Outlet Electrical DataUnits Without Electrical Convenience Outlet Electrical DataTons Voltage Compressor Electric Heat Power Supply DisconnectNominal IFM Range OFM IFM SIZE†81/2 Tons Units with Electrical Convenience Outlet Units with Electrical Convenience Outlet 40.4 45†† 195/195 13.6/15.6 57.4 59.9 60†† 208/211 Voltage Compressor Electric Power Supply Disconnect Unbalanced 3-Phase Supply Voltage SW4 Typical Wiring SchematicOutdoor-Fan Motor Typical Wiring Schematic549B072-120 Model Number Nomenclature549B E X 090 000 AA 549B036-060Base Unit 549B 549B036-072549B090,120 Base Unit Dimensions 549B036-120 549B090,120 549B036-072 ′-2 ″′-0 ″ ″ 19 NPT 827 583 44.5 12.7 NPT Enter Cooling Capacities table at outdoor entering temper Selection Procedure with 549B048 ExampleII Select Unit Based on Required Cooling CapacityEntering AIR DRY-BULB Temp F Bypass SHCFactor 2250/0.12 3000/0.15 3750/0.18 Entering Air 549B072 6 Tons Temp F1800/0.06 2100/0.066 2400/0.071 3000/0.088 Entering Air 549B090 71/2 Tons Temp F900 Cap 549B036 3 Tons549B048 4 Tons 549B072 6 Tons 549B060 5 Tons2100 Cap 549B090 71/2 Tons Temperature Air Entering Outdoor Coil F db at 70% rh549B120 10 Tons 746 806 867 929 964 1200 Rpm Bhp 900673 736 805 865 911 1000 709 782 835 900 937 1100549B072 6 Tons Standard Motor Belt Drive 549B060 5 Tons Standard Motor Belt Drive549B090 71/2 Tons Standard Motor Belt Drive 549B120 10 Tons Standard Motor Belt Drive 710 780 840 889 938 1300 584 656 734 818 875 1000627 738 800 848 895 1100 670 758 812 863 914 1200Airflow External Static Pressure in. wg Cfm Rpm Bhp 1500 1108 1187 1202 10792100 1252 1320 1388 1448 1372645 708 Rpm Bhp 2250630 695 635 699625 691 744 796 595 657 716 770605 667 725 779 615 679 734 787549B 036 ACCESSORY/FIOP Static PRESSURE* in. wg 549B036-072ACCESSORY/FIOP Static PRESSURE* in. wg 549B090,120 FAN RPM AT Motor Pulley SETTINGS* 549B036-120INDOOR-FAN Motor Data 549B036-120 Electric Heating Capacities Outdoor Sound Power Total UnitFLA MCA Mocp LRA Nominal Voltage Electric Power Minimum Unit Compressor OFMDisconnect Voltage Range Heat Supply RLA LRARLA LRA FLA Nominal Voltage Electric Power Minimum Unit CompressorIFM Disconnect Voltage Range Heat Supply Ph-Hz Min Max30.4 106/106 43.0 247/247 10.4 21.7 25.0 70.1 74.3 269/272 Typical Wiring Schematic RVS MustRating HFG. PT. no Trip Potter & Brunfield AmpsPart 1 General Guide Specifications 548F and 549B036-120 UnitsPart 2 Products Guide Specifications 548F and 549B036-120 Units Guide Specifications 548F and 549B036-120 Units 100 542J E X 150 000 AB H B Model Number Nomenclature 542J150,180 UnitsCooling HEATING-HIGH Temp HEATING-LOW Temp Sound Unit Weight Distribution and Center of GravityUnit Weight Weight of Corner Dimensions 542J150,180 UnitsSTD ALT Unit 542JSTD ALT542J 150 1895 860 180 2205 1000 Unit Maximum Shipping WeightUnit Dimensions Unit Weight of CornerCRRFCURB012A00 DIMENSIONS* degrees and inchesPKG NO. REF Curb Description Height CRRFCURB010A00 CRRFCURB011A00Height Horizontal Adapter Installation 542J150,180Accessory Curb Description Convenience Outlet 542J150,180Non-Fused Disconnect 542J150,180 Power Exhaust 542J150,180Capacity TC of 180,800 Btuh, a sensible heat capacity Selection Procedure with 542J180 Example542J180 542J150 Temp F Air Entering Indoor Coil Cfm/BF5625 Integrated Heating CapacitiesCFM General Notes for FAN Performance Tables ACCESSORY/FIOP Unit Size Unit Voltage CFM ACCESSORY/FIOP Static PRESSURE* in. wg 542J150,180FAN RPM AT Motor Pulley SETTINGS* 542J150,180 Fan Performance Using Accessory Power ExhaustGlycol Coil Data Electric Heating Capacities 542J150,180Glycol Coil Ratings INDOOR-FAN Motor Performance 542J150,180 542J180, 460-3-60 Shown CAP BKR W/ATLOR LPSOptional Non-Fused Disconnect 542J150,180 Part 1 General Guide Specifications 542J150,180 UnitsPart 2 Products Guide Specifications 542J150,180 Units 120 121 95,96 Index
Related manuals
Manual 4 pages 35.17 Kb

549B, 548F, 542J specifications

Bryant 542J is a high-efficiency gas furnace that stands out for its reliability and advanced heating technologies. Designed to deliver consistent warmth and comfort in residential settings, it combines innovative engineering with energy-efficient features.

One of the key characteristics of the Bryant 542J is its two-stage heating capability. This means that the furnace can adjust its heat output according to the heating demands of your home. During milder weather, it operates at a lower stage, consuming less energy while still maintaining a comfortable environment. When the temperatures drop, the furnace shifts to its higher capacity, providing the necessary warmth efficiently. This not only enhances comfort but also contributes to lower energy bills.

In addition to its two-stage operation, the Bryant 542J also incorporates a variable-speed blower motor. This technology allows the furnace to adjust the airflow depending on the heating requirements, ensuring an even distribution of warm air throughout the home. The variable-speed blower also operates more quietly than conventional fixed-speed motors, creating a serene indoor environment.

Energy efficiency is a hallmark of the Bryant 542J, boasting an Annual Fuel Utilization Efficiency (AFUE) rating of up to 96.5%. This impressive rating means that a significant portion of the energy consumed is effectively converted into usable heat, resulting in substantial savings on heating costs over time. Furthermore, the furnace is equipped with a sealed combustion system that draws air from outside the home, minimizing energy waste and improving indoor air quality.

Diagnostic features are another highlight of the Bryant 542J, which come equipped with SmartEvap technology. This allows the unit to self-diagnose potential issues, providing homeowners with peace of mind and simplifying maintenance procedures.

Durability is also a key feature of the Bryant 542J. It is constructed with high-quality materials designed to withstand harsh winter conditions, ensuring a long lifespan and reliable performance. Its compact design also allows for flexible installation, making it suitable for various residential layouts.

In summary, the Bryant 542J is more than just a gas furnace; it is a sophisticated heating solution that combines efficiency, comfort, and reliability. With features such as two-stage heating, a variable-speed blower, high AFUE ratings, and advanced diagnostics, it is an excellent choice for homeowners seeking an efficient and effective heating system.