Bryant 542J, 548F, 549B manual General Notes for FAN Performance Tables

Page 51

PERFORMANCE DATA (cont)

FAN PERFORMANCE — HORIZONTAL DISCHARGE UNITS (cont)

548F120 (10 TONS)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

0.2

 

 

 

 

0.4

 

 

 

0.6

 

 

 

 

 

 

0.8

 

 

1.0

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Watts

 

Rpm

Bhp

Watts

 

Rpm

Bhp

 

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

3000

 

484

 

0.55

 

562

 

560

0.70

677

 

631

0.87

 

810

690

 

1.03

940

747

1.20

 

1081

3100

 

495

 

0.61

 

607

 

570

0.76

723

 

638

0.92

 

851

699

 

1.10

998

755

1.27

 

1140

3200

 

505

 

0.66

 

646

 

579

0.81

763

 

646

0.98

 

899

708

 

1.16

1047

761

1.34

 

1199

3300

 

516

 

0.72

 

692

 

589

0.87

810

 

655

1.05

 

956

717

 

1.23

1106

767

1.40

 

1250

3400

 

527

 

0.78

 

739

 

599

0.93

859

 

664

1.11

 

1006

724

 

1.30

1165

775

1.48

 

1318

3500

 

537

 

0.85

 

795

 

609

0.99

907

 

672

1.18

 

1064

731

 

1.36

1216

784

1.56

 

1387

3600

 

548

 

0.92

 

851

 

619

1.05

956

 

680

1.24

 

1114

738

 

1.43

1275

794

1.64

 

1456

3700

 

560

 

1.00

 

916

 

629

1.12

1014

 

688

1.31

 

1173

747

 

1.51

1344

802

1.73

 

1534

3800

 

571

 

1.08

 

981

 

639

1.19

1072

 

698

1.39

 

1241

756

 

1.60

1422

810

1.81

 

1604

3900

 

582

 

1.16

 

1047

 

649

1.27

1140

 

708

1.47

 

1310

764

 

1.69

1499

816

1.89

 

1674

4000

 

593

 

1.25

 

1123

 

659

1.35

1207

 

717

1.56

 

1387

773

 

1.78

1578

823

1.98

 

1753

4100

 

605

 

1.35

 

1207

 

670

1.44

1284

 

727

1.65

 

1465

781

 

1.86

1648

832

2.08

 

1840

4200

 

616

 

1.45

 

1292

 

680

1.53

1361

 

737

1.74

 

1543

789

 

1.95

1726

841

2.18

 

1927

4300

 

628

 

1.56

 

1387

 

690

1.63

1447

 

747

1.83

 

1621

798

 

2.05

1814

849

2.30

 

2032

4400

 

639

 

1.67

 

1482

 

701

1.73

1534

 

757

1.92

 

1700

807

 

2.16

1910

858

2.41

 

2177

4500

 

651

 

1.78

 

1578

 

712

1.84

1630

 

767

2.02

 

1788

817

 

2.27

2006

866

2.51

 

2265

4600

 

662

 

1.91

 

1691

 

722

1.95

1726

 

777

2.13

 

1884

827

 

2.38

2102

874

2.62

 

2362

4700

 

674

 

2.03

 

1796

 

733

2.07

1831

 

787

2.24

 

1980

836

 

2.50

2256

882

2.73

 

2460

4800

 

686

 

2.17

 

1919

 

744

2.20

1945

 

797

2.36

 

2084

846

 

2.62

2362

891

2.85

 

2569

4900

 

698

 

2.31

 

2041

 

755

2.33

2058

 

808

2.48

 

2238

856

 

2.73

2460

900

2.99

 

2698

5000

 

710

 

2.45

 

2212

 

766

2.47

2230

 

818

2.61

 

2353

866

 

2.86

2578

910

3.12

 

2819

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

548F120 (10 TONS)* (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

1.2

 

 

 

 

1.4

 

 

 

1.6

 

 

 

 

 

 

1.8

 

 

2.0

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Watts

 

Rpm

Bhp

Watts

 

Rpm

Bhp

 

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

3000

 

800

 

1.38

 

1233

 

850

1.52

1353

 

879

1.38

 

1233

925

 

1.81

1604

964

1.92

 

1761

3100

 

805

 

1.44

 

1284

 

857

1.63

1447

 

896

1.66

 

1473

935

 

1.93

1709

975

1.98

 

1811

3200

 

812

 

1.51

 

1344

 

862

1.71

1517

 

908

1.85

 

1639

944

 

2.01

1836

984

2.09

 

1903

3300

 

819

 

1.59

 

1413

 

867

1.78

1578

 

915

1.98

 

1753

952

 

2.11

1920

993

2.22

 

2014

3400

 

827

 

1.67

 

1482

 

873

1.85

1639

 

920

2.07

 

1831

963

 

2.21

2005

1001

2.31

 

2091

3500

 

833

 

1.75

 

1552

 

880

1.94

1718

 

926

2.15

 

1901

970

 

2.41

2134

1007

2.46

 

2221

3600

 

840

 

1.83

 

1621

 

888

2.04

1805

 

931

2.23

 

1971

976

 

2.47

2230

1017

2.62

 

2362

3700

 

847

 

1.92

 

1700

 

895

2.13

1884

 

938

2.33

 

2108

981

 

2.56

2309

1024

2.77

 

2496

3800

 

856

 

2.02

 

1788

 

901

2.23

1971

 

945

2.44

 

2203

986

 

2.65

2389

1029

2.89

 

2605

3900

 

865

 

2.12

 

1875

 

908

2.32

2050

 

953

2.55

 

2300

993

 

2.75

2478

1034

3.00

 

2707

4000

 

875

 

2.22

 

1962

 

915

2.42

2186

 

960

2.65

 

2389

1000

 

2.87

2587

1039

3.10

 

2800

4100

 

883

 

2.32

 

2050

 

924

2.54

2291

 

966

2.76

 

2487

1008

 

2.99

2698

1046

3.21

 

2904

4200

 

889

 

2.41

 

2177

 

934

2.65

2389

 

972

2.87

 

2587

1015

 

3.12

2819

1053

3.34

 

3029

4300

 

896

 

2.51

 

2265

 

943

2.77

2406

 

980

2.99

 

2698

1021

 

3.23

2923

1061

3.48

 

3166

4400

 

903

 

2.62

 

2362

 

951

2.89

2603

 

990

3.12

 

2819

1028

 

3.36

3049

1068

3.61

 

3241

4500

 

912

 

2.74

 

2469

 

958

3.00

2707

 

999

3.26

 

2982

1035

 

3.51

3161

1074

3.74

 

3346

4600

 

921

 

2.87

 

2587

 

965

3.11

2810

 

1008

3.39

 

3078

1041

 

3.68

3295

1081

3.90

 

3450

4700

 

930

 

3.00

 

2707

 

972

3.23

2923

 

1017

3.45

 

3224

1048

 

3.80

3436

1088

4.13

 

3552

4800

 

938

 

3.14

 

2838

 

980

3.37

3058

 

1025

3.55

 

3362

1055

 

3.85

3584

1095

4.30

 

3653

4900

 

946

 

3.27

 

2962

 

990

3.51

3149

 

1034

3.71

 

3505

1062

 

3.98

3741

1101

4.45

 

3753

5000

 

954

 

3.39

 

3078

 

998

3.62

3271

 

1042

3.85

 

3654

1068

 

4.08

3907

1108

4.59

 

3851

 

 

LEGEND

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

 

Bhp — Brake Horsepower Input to Fan

 

 

 

 

1. Boldface indicates field-supplied drive is required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Watts — Input Watts to Motor

 

 

 

 

 

 

 

2.

 

 

indicates high-static motor and drive are required.

*Standard motor drive range: 685 to 935 rpm. Alternate motor drive

3. Maximum usable watts input is 2120 with standard motor, 2615 with

alternate motor,

and

4400

for the high-static

motor. Maximum

range: 835

to 1085

rpm. High static

motor

drive

range: 830

to

continuous

bhp

is 2.40 with

standard

motor, 2.90 with

alternate

1130 rpm. All other rpms require field-supplied drive.

 

 

 

 

 

 

motor and 5.25 with high-static motor.

 

 

 

 

Refer to this page for general Fan Performance notes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL NOTES FOR FAN PERFORMANCE TABLES

 

 

 

 

 

 

1. Extensive motor and electrical testing on these units ensures that

2.

Values include losses for filters, unit casing, and wet coils. See

the full range of the motor can be utilized with confidence. Using

 

page 52 for accessory/FIOP (factory-installed option) static pres-

your fan motors up to the wattage ratings shown will not result in

 

sure information.

 

 

 

 

 

 

nuisance tripping or premature motor failure. Unit warranty will not

3. Use of a field-supplied motor may affect wire sizing. Contact your

be affected. For additional information on motor performance, refer

 

Bryant representative for details.

 

 

 

 

to Indoor-Fan Motor Performance table on page 55.

 

4.

Interpolation is permissible. Do not extrapolate. (Belt drive units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

only.)

 

 

 

 

 

 

 

 

 

548F036-120

51

Image 51
Contents FEATURES/BENEFITS 542J150,180548F036-072 548F090-120 549B036-072 549B090-120 Table of Contents Service Options Integrated ECONOMI$ERS and Outdoor AIRINDOOR-AIR Quality Begins with Bryant Rooftops Option ACCESSORY† Options and AccessoriesEmergency Heat Control Package Options and AccessoriesBarometric RELIEF/POWER Exhaust LOW Ambient ControlsECONOMI$ER Microprocessor Controller DURA-SHIELDOUTDOOR Coil OptionsOutdoor Coil Protection Applications Electric HeatersGlycol Coil 150,180 only Convenience OutletControl BOX Hinged Panel Option Hail GuardBryant Commercial Programmable Thermostat Compressor Hinged Panel OptionOptions and Accessories Cooling, Units With EconoMi$er 548F036-072 and 549B036 ControlsSequence of Operation 542J150,180 ControlsControls Operating Modes Typical Smoke Control/Fire Shutdown Wiring 542J150,180Application Data Application Data Concentric Duct Distribution 542J150,180Concentric Duct Details 542J150,180 Typical Piping and Wiring Horizontal Discharge Ducting 548F036-120 and 549B036-120Vertical Discharge Ducting 548F036-120 and 549B036-120 Typical Piping and Wiring Model Number Nomenclature 548F Units ODS Model NumberARI* Capacity Ratings 548F036-072 Physical Data548F090-120 Physical Data072-548F036 Base Unit Dimensions CRRFCURB002A00 Accessory DimensionsConnector ALT GAS Power Control PKG. Accy Drain Hole Roof Curb Unit Size Accessory CRRFCURB001A00Accessory Dimensions III Select Electric Heat Selection Procedure with 548F048 ExampleDetermine Cooling and Heating Loads AT Design Conditions II Select Unit Based on Required Cooling CapacityEntering AIR DRY-BULB Temp F Performance DataCooling Capacities SHCPerformance Data Cooling CapacitiesEntering AIR DRY-BULB Temp F Bypass Under Air Temperature Entering Outdoor Coil FInstantaneous and Integrated Heating Ratings 4100/0.18 4700/0.21Instantaneous and Integrated Heating Ratings 2600 Cap 1800 Cap2400 Cap 3000 Cap4000 Cap CfmStandard Air 2400 Cap 3600 Cap548F036 3 Tons Alternate Motor Belt Drive FAN Performance Vertical Discharge Units548F036 3 Tons Standard Motor Direct Drive ESP548F048 4 Tons Alternate Motor Belt Drive FAN Performance Vertical Discharge Units548F060 5 Tons Standard Motor Direct Drive ESP548F060 5 Tons Alternate Motor Belt Drive 548F060 5 Tons HIGH-STATIC Motor Belt Drive 548F072 6 Tons HIGH-STATIC Motor Belt Drive 534 607 Rpm Bhp Watts511 539 518 562548F090 71/2 Tons HIGH-STATIC Motor Belt Drive 548F102 8 TONS* Standard Motor Belt Drive 548F102 81/2 Tons HIGH-STATIC Motor Belt Drive 973 2782 548F120 10 TonsRpm Bhp 963 2651FAN Performance Horizontal Discharge Units Airflow Low Speed High Speed Cfm 208 230, 460, 575Cfm Rpm Bhp Watts 548F048 4 Tons Alternate Motor Belt Drive FAN Performance Horizontal Discharge Units765 460 821 521 658 276 722 337 840 470693 327 754 388 867 531 729 388 787 450 895 593548F072 6 Tons Standard Motor Belt Drive 548F060 5 Tons HIGH-STATIC Motor Belt Drive1114 Rpm Bhp Watts 1800 942 700 1047 835 1139 9561031 1276 1900 982 779 1084 932 1160 10062500 494 554 581 723 Rpm Bhp Watts 2250 465 473 554 6302300 471 487 559 646 2400 482 524 569 6842500 542 648 619 835 686 1022 748 1258 806 Rpm Bhp Watts 2250 507 547 586 700 658 891 722 1097 7832300 513 562 592 723 663 916 727 1131 786 2400 528 600 606 779 674 965 738 1199 795548F102 81/2 Tons Standard Motor Belt Drive 3200 652 1089 718 1327 778 1595 831 1849 Rpm Bhp Watts 2550 669 627 867 692 1056 754 1292 8122900 604 867 676 1089 737 1318 794 1560 848 3100 636 1006 704 1241 764 1499 818 1744General Notes for FAN Performance Tables Component CFM ACCESSORY/FIOP Static PRESSURE* in. wg 548F036-072ACCESSORY/FIOP Static PRESSURE* in. wg 548F090-120 FAN RPM AT Motor Pulley SETTINGS* 548F036-120Mocp Size Optional Power ExhaustEconoMi$er Barometric Relief Damper Characteristics Power RequirementsDistribution Electric Heating CapacitiesMultiplication Factors Heater Rating090 INDOOR-FAN Motor Performance 548F UnitsUnit INDOOR-FAN Maximum Acceptable Motor Operating Watts AMP Draw Efficiency %Units Without Electrical Convenience Outlet Electrical DataUnits Without Electrical Convenience Outlet Electrical DataTons Voltage Compressor Electric Heat Power Supply DisconnectNominal IFM Range OFM IFM SIZE†81/2 Tons Units with Electrical Convenience Outlet Units with Electrical Convenience Outlet 40.4 45†† 195/195 13.6/15.6 57.4 59.9 60†† 208/211 Voltage Compressor Electric Power Supply Disconnect Unbalanced 3-Phase Supply Voltage SW4 Typical Wiring SchematicOutdoor-Fan Motor Typical Wiring Schematic549B072-120 Model Number Nomenclature549B E X 090 000 AA 549B036-060Base Unit 549B 549B036-072549B090,120 Base Unit Dimensions 549B036-120 549B090,120 ′-2 ″ 549B036-072′-0 ″ ″ 19 NPT 827 583 44.5 12.7 NPT Enter Cooling Capacities table at outdoor entering temper Selection Procedure with 549B048 ExampleII Select Unit Based on Required Cooling CapacitySHC Entering AIR DRY-BULB Temp F BypassFactor 2250/0.12 3000/0.15 3750/0.18 Entering Air 549B072 6 Tons Temp F1800/0.06 2100/0.066 2400/0.071 3000/0.088 Entering Air 549B090 71/2 Tons Temp F549B036 3 Tons 900 Cap549B048 4 Tons 549B060 5 Tons 549B072 6 Tons2100 Cap Temperature Air Entering Outdoor Coil F db at 70% rh 549B090 71/2 Tons549B120 10 Tons 746 806 867 929 964 1200 Rpm Bhp 900673 736 805 865 911 1000 709 782 835 900 937 1100549B072 6 Tons Standard Motor Belt Drive 549B060 5 Tons Standard Motor Belt Drive549B090 71/2 Tons Standard Motor Belt Drive 549B120 10 Tons Standard Motor Belt Drive 710 780 840 889 938 1300 584 656 734 818 875 1000627 738 800 848 895 1100 670 758 812 863 914 1200Airflow External Static Pressure in. wg Cfm Rpm Bhp 1500 1108 1187 1202 10792100 1252 1320 1388 1448 1372645 708 Rpm Bhp 2250630 695 635 699625 691 744 796 595 657 716 770605 667 725 779 615 679 734 787549B 036 ACCESSORY/FIOP Static PRESSURE* in. wg 549B036-072ACCESSORY/FIOP Static PRESSURE* in. wg 549B090,120 FAN RPM AT Motor Pulley SETTINGS* 549B036-120INDOOR-FAN Motor Data 549B036-120 Electric Heating Capacities Outdoor Sound Power Total UnitFLA MCA Mocp LRA Nominal Voltage Electric Power Minimum Unit Compressor OFMDisconnect Voltage Range Heat Supply RLA LRARLA LRA FLA Nominal Voltage Electric Power Minimum Unit CompressorIFM Disconnect Voltage Range Heat Supply Ph-Hz Min Max30.4 106/106 43.0 247/247 10.4 21.7 25.0 70.1 74.3 269/272 Typical Wiring Schematic RVS MustRating HFG. PT. no Trip Potter & Brunfield AmpsGuide Specifications 548F and 549B036-120 Units Part 1 GeneralPart 2 Products Guide Specifications 548F and 549B036-120 Units Guide Specifications 548F and 549B036-120 Units 100 542J E X 150 000 AB H B Model Number Nomenclature 542J150,180 UnitsCooling HEATING-HIGH Temp HEATING-LOW Temp Sound Unit Weight Distribution and Center of GravityUnit Weight Weight of Corner Dimensions 542J150,180 UnitsSTD ALT Unit 542JSTD ALT542J 150 1895 860 180 2205 1000 Unit Maximum Shipping WeightUnit Dimensions Unit Weight of CornerCRRFCURB012A00 DIMENSIONS* degrees and inchesPKG NO. REF Curb Description Height CRRFCURB010A00 CRRFCURB011A00Height Horizontal Adapter Installation 542J150,180Accessory Curb Description Convenience Outlet 542J150,180Non-Fused Disconnect 542J150,180 Power Exhaust 542J150,180Capacity TC of 180,800 Btuh, a sensible heat capacity Selection Procedure with 542J180 Example542J180 542J150 Temp F Air Entering Indoor Coil Cfm/BFIntegrated Heating Capacities 5625CFM General Notes for FAN Performance Tables ACCESSORY/FIOP Unit Size Unit Voltage CFM ACCESSORY/FIOP Static PRESSURE* in. wg 542J150,180FAN RPM AT Motor Pulley SETTINGS* 542J150,180 Fan Performance Using Accessory Power ExhaustElectric Heating Capacities 542J150,180 Glycol Coil DataGlycol Coil Ratings INDOOR-FAN Motor Performance 542J150,180 542J180, 460-3-60 Shown CAP BKR W/ATLOR LPSOptional Non-Fused Disconnect 542J150,180 Guide Specifications 542J150,180 Units Part 1 GeneralPart 2 Products Guide Specifications 542J150,180 Units 120 121 95,96 Index
Related manuals
Manual 4 pages 35.17 Kb

549B, 548F, 542J specifications

Bryant 542J is a high-efficiency gas furnace that stands out for its reliability and advanced heating technologies. Designed to deliver consistent warmth and comfort in residential settings, it combines innovative engineering with energy-efficient features.

One of the key characteristics of the Bryant 542J is its two-stage heating capability. This means that the furnace can adjust its heat output according to the heating demands of your home. During milder weather, it operates at a lower stage, consuming less energy while still maintaining a comfortable environment. When the temperatures drop, the furnace shifts to its higher capacity, providing the necessary warmth efficiently. This not only enhances comfort but also contributes to lower energy bills.

In addition to its two-stage operation, the Bryant 542J also incorporates a variable-speed blower motor. This technology allows the furnace to adjust the airflow depending on the heating requirements, ensuring an even distribution of warm air throughout the home. The variable-speed blower also operates more quietly than conventional fixed-speed motors, creating a serene indoor environment.

Energy efficiency is a hallmark of the Bryant 542J, boasting an Annual Fuel Utilization Efficiency (AFUE) rating of up to 96.5%. This impressive rating means that a significant portion of the energy consumed is effectively converted into usable heat, resulting in substantial savings on heating costs over time. Furthermore, the furnace is equipped with a sealed combustion system that draws air from outside the home, minimizing energy waste and improving indoor air quality.

Diagnostic features are another highlight of the Bryant 542J, which come equipped with SmartEvap technology. This allows the unit to self-diagnose potential issues, providing homeowners with peace of mind and simplifying maintenance procedures.

Durability is also a key feature of the Bryant 542J. It is constructed with high-quality materials designed to withstand harsh winter conditions, ensuring a long lifespan and reliable performance. Its compact design also allows for flexible installation, making it suitable for various residential layouts.

In summary, the Bryant 542J is more than just a gas furnace; it is a sophisticated heating solution that combines efficiency, comfort, and reliability. With features such as two-stage heating, a variable-speed blower, high AFUE ratings, and advanced diagnostics, it is an excellent choice for homeowners seeking an efficient and effective heating system.