Bryant 286A instruction manual CUT Hazard, Indoor Thermostat Control Options

Page 1

286A / 288A

Evolutiont Series Heat Pumps with Puronr Refrigerant 2 To 5 Nominal Tons (Sizes 024 to 060)

Installation Instruction

NOTE: Read the entire instruction manual before starting the installation.

Unless otherwise noted, information in these installation instructions pertain to both 286A and 288A series units. Information that is unique to the 286A series will be identified as such; likewise information that is unique to the 288A series will also be identified.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and current editions of the National Electrical Code ( NEC ) NFPA 70. In Canada, refer to current editions of the Canadian electrical code CSA 22.1.

Recognize safety information. This is the safety-alert symbol ! When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

!CAUTION

CUT HAZARD

Failure to follow this caution may result in personal injury.

Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts.

Indoor Thermostat Control Options

 

Evolution

Standard

Model

2---stage

Control

 

Thermostat

 

 

 

 

 

286A

Yes

Yes

 

 

 

288A

Yes

Yes*

 

 

 

* Units containing circuit board HK38EA015 or newer.

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position and install a lockout tag. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label.

!WARNING

UNIT OPERATION AND SAFETY HAZARD

Failure to follow this warning could result in personal injury or equipment damage.

PuronR refrigerant systems operate at higher pressures than standard R-22 systems. Do not use R-22 service equipment or components on PuronR refrigerant equipment.

Image 1
Contents CUT Hazard Unit Operation and Safety HazardIndoor Thermostat Control Options Electrical Shock HazardCheck Equipment and Job Site Install on a Solid, Level Mounting PadClearance Requirements Unpack UnitElevate Unit Operating AmbientMake Piping Connections Outdoor Unit Connected to Factory-Approved IndoorLiquid Rated Vapor Unit Size Accessory UsageMake Electrical Connections Make Airflow Selections Install AccessoriesCompressor Crankcase Heater System Functions and Sequence of Operation Start-UpTime Delays One Minute Stage Change Time Delay on 286A ModelsCompressor Operation on 286A Models Crankcase Heater OperationDefrost Low Ambient CoolingEvolution Controlled low ambient cooling Check Charge Control Fault Pressure Switch ProtectionStage Control Board Field ConnectionsUnloader Test Procedure 230V Line Power Disconnect DetectionTemperature Thermistors Compressor Voltage SensingThermistor Sensor Comparison Failed Thermistor Default OperationStatus Codes TroubleshootingEdge Thermidistat Models T6-PRH-01 or T6-NRH-01 Final Checks Care and MaintenancePuronr R-410A Refrigerant Quick Reference Guide