286A / 288A
Table 1 – Refrigerant Connections and Recommended Liquid and Vapor Tube Diameters (in.)
Information is Specific to 286A and 288A Models
| LIQUID |
| RATED VAPOR* | ||
UNIT SIZE |
|
|
|
|
|
Connection |
| Tube | Connection | Tube | |
| Diameter |
| Diameter | Diameter | Diameter |
|
|
|
|
|
|
286A024 | 3/8 |
| 3/8 | 5/8 | 5/8 |
|
|
|
|
|
|
286A036 | 3/8 |
| 3/8 | 3/4 | 3/4 |
|
|
|
|
|
|
286A048 | 3/8 |
| 3/8 | 7/8 | 7/8 |
|
|
|
|
|
|
286A060 | 3/8 |
| 3/8 | 7/8 | |
|
|
|
|
|
|
|
|
|
|
|
|
288A024 | 3/8 |
| 3/8 | 3/4 | 3/4 |
288A036 | 3/8 |
| 3/8 | 3/4 | 3/4 |
288A048 | 3/8 |
| 3/8 | 7/8 | 7/8 |
288A060 | 3/8 |
| 3/8 | 7/8 |
* Units are rated with 25 ft. (7.6 m) of lineset. See Product Data sheet for performance data when using different size and length linesets.
Notes:
1. Do not apply capillary tube or the fixed orifice indoor coils to these units.
2For Tubing Set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal or 20 ft. (6.10 m) vertical differential (250 ft./76.2 m Total Equivalent Length), refer to the Residential Piping and Long Line Guideline for Air Conditioners and Heat Pumps using Puron® Refrigerant.
Table 2 – Accessory Usage
| REQUIRED FOR | REQUIRED FOR LONG LINE | REQUIRED FOR SEA COAST | |
ACCESSORY | COOLING APPLICATIONS | APPLICATIONS | ||
APPLICATIONS* | ||||
| (Below 55°F/12.8_C) | (Within 2 miles/3.22 km) | ||
|
| |||
Crankcase Heater | Standard | Standard | Standard | |
| Standard with Evolutiont Control |
|
| |
Evaporator Freeze Protection | (Low Ambient not allowed with | No | No | |
| non |
|
| |
| Standard with Evolution Control |
|
| |
Winter Start Control | (Low Ambient not allowed with non | No | No | |
| communicating thermostat) |
|
| |
Compressor Start Assist Capacitor | Standard on 286A models. | Standard on 286A models. | Standard on 286A models | |
and Relay} | Not required for 288A | Not required for 288A | Not required for 288A | |
| Standard with Evolution Control |
|
| |
(Low ambient not allowed with non | No | No | ||
| communicating thermostat) |
|
| |
Support Feet | Recommended | No | Recommended | |
No | Yes | No | ||
Puron Refrigerant Balance Port | Yes{ | Yes{ | Yes{ | |
|
|
|
*For tubing set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal or 20 ft. (6.10 m) vertical differential (total equivalent length), refer to the Residential Piping and Long Line Guideline for Air Conditioners and Heat Pumps using Puron® Refrigerant.
{Required on all indoor units. Standard on all new Puron refrigerant fan coils and furnace coils. } Information is specific to 286A and 288A models.
ISO 9001:2000
the environmentally sound refrigerant | REGISTERED |
This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant
charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life.
Ready for use in a Hybrid Heatr Duel Fuel system.
4