Powermatic WP2510 operating instructions Troubleshooting Mechanical and Electrical Problems

Page 37

Troubleshooting: Mechanical and Electrical Problems

Trouble

Uneven depth of cut side to side.

Board thickness does not match depth of cut scale.

Chain is jumping.

Machine will not start/restart or repeatedly trips circuit breaker or blows fuses.

Probable Cause

Remedy

 

 

Knife inserts not set correctly.

Make sure knife inserts are set

correctly and securely in cutterhead.

 

 

 

Planer table not level with cutterhead.

Level the table. See pages 16-17.

 

 

Depth of cut scale is incorrect.

Adjust depth of cut scale. Use LED

control panel for greater precision.

 

 

 

Inadequate chain tension.

Adjust chain tension.

 

 

Sprockets misaligned.

Align sprockets.

 

 

Sprockets worn.

Replace sprockets.

 

 

No incoming power.

Verify machine is connected to power.

 

 

Stop button is still engaged.

Rotate stop button to disengage.

 

 

 

When the planer overloads on the

 

circuit breaker built into the motor

 

starter, it takes time for the machine

Overload automatic reset has not

to cool down before restart. Allow

reset.

machine to adequately cool before

 

attempting restart. If problem persists,

 

check amp setting on the motor

 

starter inside the electrical box.

 

 

 

One cause of overload trips which are

 

not electrical in nature is too deep a

 

cut. The solution is to take a lighter

 

cut. If too deep a cut is not the

 

problem, check the amp setting on

Planer frequently trips.

the overload relay. Match the full load

 

amps on the motor as noted on the

 

motor plate.

 

If amp setting is correct, then there is

 

probably a loose electrical lead or a

 

failed component. See items below.

 

 

 

Verify that planer is on a circuit of

Building circuit breaker trips or fuse

correct size. If circuit size is correct,

there is probably a loose electrical

blows.

lead. Check amp setting on motor

 

 

starter.

 

 

 

Go through all of the electrical

 

connections on the planer including

 

motor connections, verifying the

Loose electrical connections.

tightness of each. Look for any signs

 

of electrical arcing which is a sure

 

indicator of loose connections or

 

circuit overload.

 

 

37

Image 37
Contents Inch Planer More Information Warranty and ServiceTable of Contents Page Page Page TEFC, 1/2HP, 3Ph Introduction SpecificationsUnpacking Contents of the Shipping ContainerDust Hood Installation and AssemblyVolt Operation Grounding InstructionsConverting from 230 Volt to 460 Volt AdjustmentsTest Run Controller Set-UpBelt Tension Feed RateOpening Hood Knife InsertsAnti-Kickback Fingers Planer’s Feed SystemChipbreaker Pressure Bar Table Adjustments Feed Restriction Test Cutting and TroubleshootingClip Marks Operation MaintenanceLubrication Front Panel Overview Controller M15S Operating InstructionsOperation Modes Manual ModeStart/Stop/Cancel Setting Target ValueExample Fast Program 10 sets Entering preset target valuesExecute Select Counting direction Select Positioning ModeSet Tolerances Set Software Limit Hi/Lo EndTo set low speed limit Set Low Speed LimitSet Linear Correction Enter Parameter Setttings ModeLoad Datum Values Check Software VersionExample 13. IN/MM Conversion Set Device ResolutionCalibration 16. M15S Troubleshooting DisplayPossible cause Incorrect operation Excluding Press to clear 17. M15S Specifications Troubleshooting Planer Operating Problems Troubleshooting Mechanical and Electrical Problems Replacement Parts Column Assembly Index No. Part No Description Size Qty Parts List Column AssemblyWP2510-458 Gearbox Assembly Parts List Gearbox Assembly Parts List Cutterhead Assembly 6012162 Table Assembly Parts List Table Assembly Base Assembly Parts List Base Assembly WP2510-660 122 Parts List Top Cover Assembly Parts List Electrical Box Assembly Electrical Connections 230Volt Electrical Connections 460Volt WMH Tool Group