Roberts Gorden EP-203, EP-200 Series Pump Assembly, Attaching the Inlet Plate Assembly

Page 13

SECTION 5: PUMP INSTALLATION

FIGURE 3: Pump Assembly

5/16 x 7/8" Screws (w/flat washers) - 16 Req'd.

Pump Scroll

Pressure Switch

1/8” NPT

Rubber

Inlet Plate Assembly

1" NPT

 

Mounts

Partial End View

 

 

 

Impeller

Gasket (2 pieces)

 

Description

Part Number

Pressure Switch

90430600

Pump Scroll

01394400

Rubber Mounts

91906100

Impeller

01394602

Description

Part Number

Inlet Plate Assembly Kit

01327400

Gaskets (2)

91406940

Inlet Plate

01327400

Accessory Bag (8 bolts, 8 flat washers)

01311702

5.1.3 Attaching the Inlet Plate Assembly

Following installation of the pump scroll to the pump frame, attach the inlet plate assembly to the pump scroll as follows:

Place flat washer on the 5/16" x 7/8" screw.

Position a single section of the gasket against the face of the pump scroll; align the clearance holes of the gasket with the mounting holes of the pump scroll. Loosely install one 5/16" x 7/8" screw through the gasket segment and into the top cen- ter mounting hole of the pump scroll to support the gasket.

Interlock the remaining gasket segment to the previously installed gasket segment to complete the circular gasket.

Orient the inlet plate assembly as shown. The 1/8" NPT plug should face directly up, and the 1" NPT plug should face directly downward. Care- fully position the top center mounting notch of the inlet plate assembly to engage the mounting screw positioned

previously.

Install the seven remaining 5/16" x 7/8" screws through the notches in the inlet plate assembly

and into the corresponding mounting holes in the pump scroll.

Tighten screws to complete installation of the inlet plate assembly.

Install pressure switch in 1/8" NPT hole in top of outlet.

7

Image 13
Contents EP-200 Series Pump Page 2004 Table of ContentsPage Major Component Descriptions Table of FiguresPage Manpower Requirements Heating System SafetyCorrosive Chemicals Installer ResponsibilityNational Standards and Applicable Codes Unpacking the Pump 3.1 Open Shipping CartonsMajor Components 01311700 EP-200 Series Accessory Package EP-203 Pump Package P/N Description Quantity Attaching Pump Scroll Pump InstallationAttaching the Inlet Plate Assembly Pump AssemblyInstall Motor Shaft Seal Motor Shaft Seal AssemblyPump Suspension Wall Mounting Angle Assembly Wall Bracket AssemblyWall Mounting Mounting Platform Optional Platform AssemblyCondensate Trap and Condensate Tee Condensate Check ValveEP-201 Motor Wiring Motor WIRING6.1 Prior to OperationVent Length Vent Size Venting18 min.-40 max Cm min Cm max 10 3 m Vertical Venting Servicing Instructions Pre-Season Maintenance and Annual InspectionTo Change the Motor and/or the Impeller Pressure Switch Pump BootPump Scroll, Impeller and Motor Suspension PointsReplacement Parts Replacement Parts and AccessoriesAccessories Pump Specifications Model EP-201 EP-203 SpecificationsPage Roberts Gordon EP-200 Warranty is Void ifROBERTS-GORDON will not PAY for Limitations on Authority Representatives