Roberts Gorden EP-200 Series, EP-203 service manual Pump Installation, Attaching Pump Scroll

Page 12

EP-200 SERIES PUMP INSTALLATION, OPERATION AND SERVICE MANUAL

SECTION 5: PUMP INSTALLATION

5.1 Pump Assembly Instructions

5.1.1 Determine Orientation of Pump Discharge

To ensure your safety, and comply with the terms of the warranty, all units must be installed in accor- dance with these instructions.

The pump must be installed in a location that it is readily accessible for servicing.

An arrow is affixed to the outside of the pump scroll to indicate the direction of rotation of the impeller. The standard rotation of the impeller is in the coun- terclockwise direction.

Pump discharge orientation and impeller rotation direction is viewed from the rear of the motor as shown in on Page 6, Figure 2. Note that the pump scroll outlet must always be positioned at the bottom horizontal position.

FIGURE 2: Pump Discharge Orientation / Impeller Rotation Direction

Counterclockwise Rotation

(Standard)

OUTLET

Arrow showing direction of rotation (located on front of scroll housing)

Clockwise Rotation

OUTLET

5.1.2 Attaching Pump Scroll

After determining the correct orientation of the pump scroll outlet, attach the pump scroll to the pump frame as follows:

Place Flat Washer (P/N 95211600), on the 5/16" x 7/8" Screw (P/N 94273914).

From the motor side of the vertical mounting plate of the pump frame, insert the 5/16" x 7/8" screws.

Install two pieces of the gasket material on the exposed thread ends of the mounting screws. Make sure the ends of the opposing gasket seg- ments interlock to form a complete circular gasket.

Carefully position the pump scroll against the ver- tical mounting plate of the pump frame; align and loosely install the 5/16" x 7/8" screws into the cor- responding mounting holes in the pump scroll.

While tightening the screws that secure the pump scroll to the motor frame, periodically spin the impeller to be sure that adequete clearance is maintained between the impeller blades and the body of the pump scroll.

6

Image 12
Contents EP-200 Series Pump Page Table of Contents 2004Page Table of Figures Major Component DescriptionsPage Heating System Safety Manpower RequirementsInstaller Responsibility Corrosive ChemicalsNational Standards and Applicable Codes Unpacking the Pump 3.1 Open Shipping CartonsMajor Components 01311700 EP-200 Series Accessory Package EP-203 Pump Package P/N Description Quantity Pump Installation Attaching Pump ScrollPump Assembly Attaching the Inlet Plate AssemblyMotor Shaft Seal Assembly Install Motor Shaft SealWall Mounting Angle Assembly Wall Bracket Assembly Pump SuspensionMounting Platform Optional Platform Assembly Wall MountingCondensate Check Valve Condensate Trap and Condensate TeeMotor WIRING6.1 Prior to Operation EP-201 Motor WiringVenting Vent Length Vent Size18 min.-40 max Cm min Cm max 10 3 m Vertical Venting Pre-Season Maintenance and Annual Inspection Servicing InstructionsTo Change the Motor and/or the Impeller Pump Boot Pressure SwitchPump Scroll, Impeller and Motor Suspension PointsReplacement Parts and Accessories Replacement PartsAccessories Specifications Pump Specifications Model EP-201 EP-203Page Warranty is Void if Roberts Gordon EP-200ROBERTS-GORDON will not PAY for Limitations on Authority Representatives

EP-203, EP-200 Series specifications

The Roberts Gordon EP-200 Series, especially the EP-203 model, is a revolutionary line of infrared heating systems designed for industrial and commercial applications. These heaters are renowned for their efficiency, performance, and innovative features, making them a preferred choice for customers seeking reliable heating solutions.

One of the main features of the EP-200 Series is its advanced infrared heating technology. Unlike traditional heating systems that rely on air convection, infrared heaters warm objects and surfaces directly. This results in faster heating times and a more consistent temperature within the space. The EP-203 model features a unique design that allows for flexibility in installation, whether it is mounted on ceilings, walls, or even used in portable applications.

The EP-203 is engineered for optimal performance, utilizing a high-quality ceramic burner that delivers uniform heat distribution. This technology not only enhances comfort but also reduces energy consumption, making the system exceptionally cost-effective over time. The EP-200 Series is also designed with longevity in mind, utilizing durable materials that withstand the rigors of industrial environments.

Another standout characteristic of the Roberts Gordon EP-200 Series is its straightforward controls. The EP-203 can be easily integrated with advanced control systems, including thermostats and smart building technologies, allowing users to manage heating efficiently and adapt to varying environmental conditions.

Safety is a priority in the design of the EP-200 Series. The EP-203 is equipped with several safety features, including automatic shut-off mechanisms, flame safeguards, and overheat protection. These features ensure not only the safety of the equipment but also the wellbeing of personnel in the vicinity.

Additionally, the EP-200 Series is recognized for its environmental consideration. These heaters operate on clean-burning fuels, minimizing greenhouse gas emissions while providing powerful heating capabilities. This aligns with modern sustainability goals, making it an ideal choice for businesses looking to reduce their carbon footprint.

In summary, the Roberts Gordon EP-200 Series and its EP-203 model represent cutting-edge technology in infrared heating solutions. With features focusing on efficiency, safety, and environmental sustainability, they are well-suited for a variety of applications, ensuring comfort and cost savings for users in the industrial and commercial sectors. These attributes, combined with the brand's reputation for quality and performance, solidify its position in the heating market.