Miller Electric ICE-27C, 375 manual Specifications For Torch, Non-CE Model

Page 15

SECTION 4 − INSTALLATION

4-1. Specifications

NOTE

If the unit is operated from a 30* ampere, 115 volt circuit or a 15** ampere, 230 volt circuit, a different input power plug must be installed on the power cord. See Section 4-9for instructions.

*A 30 ampere branch circuit is recommended for maximum performance. Performance on a 20 ampere branch service may be limited due to the circuit breaker or line fuse. Reducing unit output amperage will minimize circuit breaker tripping or blowing a line fuse.

**A 15 ampere branch circuit is recommended for maximum performance. Performance on a 10 ampere branch service may be limited due to the circuit breaker or line fuse. Reducing unit output amperage will minimize circuit breaker tripping or blowing a line fuse.

A. Non-CE Model

 

Amperes Input at

 

 

 

 

 

 

 

Rated Output,

 

 

 

 

Rated

 

 

60 Hz, Single-Phase

 

 

 

 

 

 

 

 

 

Plasma

Cutting

 

 

 

 

 

 

 

 

 

115 V

230 V

115 V

230 V

Plasma

Gas Flow/

Capacity

Max

Rated Output

(+15%)

(+15%)

KVA/KW

KVA/KW

Gas

Pressure

at 10 IPM

OCV

 

 

 

 

 

 

 

 

 

27 A at 92 Volts DC At

28 max;

14 max;

3.32 KVA

3.25 KVA

Air Or

4.5 CFM

3/8 in

288 Volts

(129 L/min)

Nitrogen

35% Duty Cycle

0.30*

0.13*

3.25 KW

3.19 KW

At 60 PSI

(10 mm)

DC

Only

 

 

 

 

 

(414 kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*While idling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B. CE Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amperes Input at

 

 

 

 

 

 

 

Rated Output,

 

 

 

 

Rated

 

 

50 Hz, Single-Phase

 

 

 

 

 

 

 

 

 

Plasma

Cutting

 

 

 

 

 

 

 

 

 

115 V

230 V

115 V

230 V

Plasma

Gas Flow/

Capacity

Max

Rated Output

(+15%)

(+15%)

KVA/KW

KVA/KW

Gas

Pressure

at 10 IPM

OCV

 

 

 

 

 

 

 

 

 

27 A at 92 Volts DC At

27 max;

13 max;

3.11 KVA

3.04 KVA

Air Or

4.5 CFM

3/8 in

288 Volts

(129 L/min)

Nitrogen

35% Duty Cycle

0.33*

0.17*

3.09 KW

3.04 KW

At 60 PSI

(10 mm)

DC

Only

 

 

 

 

 

(414 kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*While idling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-2. Specifications For Torch

 

 

 

 

 

 

 

 

 

 

 

 

 

Air-cooled torch for plasma arc cutting (PAC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35% duty cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety interlock devices shut down power source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety trigger guard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cutting capacity: see Section 4-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OM-2229 Page 11

Image 15
Contents OM-2229200 879N ProcessesDescription From Miller to You Table of Contents Standards DirectivesCutting can cause fire or explosion Symbol UsageMarks a special safety message Plasma Arc Cutting HazardsNoise can damage hearing Exploding Parts can injureFlying Sparks can cause injury ARC Rays can burn eyes and skinCalifornia Proposition 65 Warnings Principal Safety Standards EMF InformationAbout Pacemakers Identifie un message de sécurité particulier Signification des symbolesLE Coupage présente un risque de feu ou d’explosion UNE Décharge Électrique peut entraîner la mortLE Plasma D’ARC peut entraîner des blessures Risque de blessure en casLE Bruit peut endommager l’ouïe LES Fumées ET LES GAZ peuvent être dangereuxDES Particules Volantes peuvent blesser les yeux LES Bouteilles peuvent exploser si elles sont endommagéesDES Pieces Chaudes peuvent pro- voquer des brûlures graves DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sécurité Information sur les champs électromagnétiquesConsignes relatives aux stimulateurs cardiaques 55.1 + + +I1eff I1maxCE Model SpecificationsSpecifications For Torch Non-CE ModelOverheating Torch Dimensions And WeightExceeding duty cycle can damage unit and void warranty Duty Cycle And OverheatingSelecting a Location Connecting Gas/Air Supply Connecting Input Power Connecting Work ClampInstalling Alternative Plug Setting Gas/Air Pressure Controls60 PSI Cutting Speed Trigger Safety LockSparks go thru metal Sequence Of Operation− Maintenance & Troubleshooting Checking Torch Shield Cup Shutdown System Always turn Off power when changing or checking consumablesTorch And Work Cable Connections Torch ConnectionsWork Cable Connections Checking/Replacing Retaining Cup, Tip, And Electrode Turn Off power source before checking torch partsTroubleshooting Power Source Reset unit Go to Section Troubleshooting Torch− Electrical Diagram OM-2229 − Parts List Item Diagram Part Marking Description Quantity Torch, ICE-27C Support ServiceMiller Electric Mfg. Co Owner’s Record